Development of a novel PVC membrane lidocaine-selective potentiometric sensor based on MIL-53 (Al) metal organic framework as a functional material
Özet
Lidocaine is the most commonly used local anesthetic and can be used to reduce the feeling of pain caused by the stability of the nerve membrane and the pain that occurs at the end of the nerve signals in the skin. Due to the fact that lidocaine overdose causes side effects, determination of lidocaine is of great importance. The present study presents the development of a novel, simple, low-cost and reliable PVC membrane lidocaine hydrochloride-selective potentiometric sensor based on MIL-53(Al) metal organic framework (MOF) as a selective sensing functional material. The proposed sensor exhibited a linear potentiometric response for lidocaine hydrochloride in the concentration range of 1.0 × 10−7M−1.0 × 10−1M with the potential change of 55.4 mV/decade and a detection limit of 5.0 × 10−8M. The response time and the pH working range of the sensor were determined as 10 s and 2.37–7.45, respectively. These performance characteristics denote that the potentiometric lidocaine hydrochloride-selective sensor has quite superior properties. The potentiometric application of the lidocaine hydrochloride-selective sensor was successfully applied in pharmaceutical preparations. © 2025 World Scientific Publishing Company.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Gumus, Seyhmus | |
| dc.contributor.author | Kanberoglu, Gulsah Saydan | |
| dc.contributor.author | Kaya, Nurcan | |
| dc.contributor.author | Coldur, Fatih | |
| dc.date.accessioned | 2026-10-18T20:25:45.968088531Z | |
| dc.date.available | 2026-10-18T20:25:45.968088531Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | Lidocaine is the most commonly used local anesthetic and can be used to reduce the feeling of pain caused by the stability of the nerve membrane and the pain that occurs at the end of the nerve signals in the skin. Due to the fact that lidocaine overdose causes side effects, determination of lidocaine is of great importance. The present study presents the development of a novel, simple, low-cost and reliable PVC membrane lidocaine hydrochloride-selective potentiometric sensor based on MIL-53(Al) metal organic framework (MOF) as a selective sensing functional material. The proposed sensor exhibited a linear potentiometric response for lidocaine hydrochloride in the concentration range of 1.0 × 10−7M−1.0 × 10−1M with the potential change of 55.4 mV/decade and a detection limit of 5.0 × 10−8M. The response time and the pH working range of the sensor were determined as 10 s and 2.37–7.45, respectively. These performance characteristics denote that the potentiometric lidocaine hydrochloride-selective sensor has quite superior properties. The potentiometric application of the lidocaine hydrochloride-selective sensor was successfully applied in pharmaceutical preparations. © 2025 World Scientific Publishing Company. | |
| dc.description.sponsorship | We thank Mustafa Tekp\u0131nar for his help in editing the language of the text. This study was supported by the Van Yuzuncu Yil University Scientific Research Projects Coordination Unit under Grant No. FYL-2023-10759. | |
| dc.identifier.doi | 10.1142/s1793604725510737 | |
| dc.identifier.eissn | 1793-7213 | |
| dc.identifier.issn | 1793-6047 | |
| dc.identifier.issue | 7 | |
| dc.identifier.scopus | 2-s2.0-105020723678 | |
| dc.identifier.startpage | 2551073 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/10571 | |
| dc.identifier.volume | 18 | |
| dc.identifier.wos | WOS:001611809600001 | |
| dc.language.iso | en | |
| dc.publisher | World Scientific | |
| dc.relation.ispartof | Functional Materials Letters | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Drug analysis | |
| dc.subject | lidocaine determination | |
| dc.subject | metal-organic frameworks | |
| dc.subject | MIL-53(Al) | |
| dc.subject | potentiometric sensor | |
| dc.subject | Anesthetics | |
| dc.subject | Chemical sensors | |
| dc.subject | Crystalline materials | |
| dc.subject | Functional materials | |
| dc.subject | Metal analysis | |
| dc.subject | Potentiometers (electric measuring instruments) | |
| dc.subject | Al-metal | |
| dc.subject | Functionals | |
| dc.subject | Lidocaine hydrochloride | |
| dc.subject | Metalorganic frameworks (MOFs) | |
| dc.subject | Potentiometrics | |
| dc.subject | PVC membrane | |
| dc.subject | Selective sensors | |
| dc.subject | Potentiometric sensors | |
| dc.title | Development of a novel PVC membrane lidocaine-selective potentiometric sensor based on MIL-53 (Al) metal organic framework as a functional material | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 0 | |
| rdl.citation.wos | 0 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |