Clinical Assessment of Medical Device–Related Pressure Injury Risk: Profiling Risk Levels in Patients Using Medical Devices

ArticleAçık Erişim

Özet

Objective: This study aimed to evaluate the risk of medical device-related pressure injury (MDRPI) development among patients exposed to medical devices and to assess the clinical utility of the Medical Device-Related Pressure Injury Risk Assessment Scale (MDRPIS). Methods: This clinical assessment study included 132 patients receiving care in intensive care, palliative care, and home-care units. The MDRPIS total score ranges from 8 to 27, with scores of 8–12 indicating high risk, 13–21 indicating moderate risk, and 22–27 indicating low risk. The scale was used to assess MDRPI risk associated with life-sustaining medical devices. Its psychometric performance was evaluated through analyses of internal consistency, criterion validity against the Braden Scale, and diagnostic accuracy using receiver operating characteristic (ROC) analysis. Results: The MDRPIS demonstrated strong discriminative ability for identifying patients at risk of MDRPI, with an area under the curve (AUC) of 0.822. A cut-off score of ≤16 was identified as the optimal threshold for detecting high-risk patients. Patients with MDRPIS scores of 16 or lower had a significantly higher incidence of MDRPI than those classified as low risk (p < 0.001). Respiratory support devices, particularly non-invasive ventilation (NIV)/continuous positive airway pressure (CPAP) masks and tracheostomy flanges or securement devices, were identified as the most significant risk factors for injury development. The highest incidence of MDRPI was observed among patients in intensive care units, followed by those in palliative care and home-care settings, indicating a statistically significant concentration of device-related risk in high-acuity care environments (p < 0.05). Conclusions: Clinical settings, particularly intensive care and palliative care units, should incorporate the MDRPIS into routine risk assessment protocols to facilitate targeted preventive interventions, including prophylactic dressings and advanced fixation techniques for patients using high-risk devices such as NIV masks and tracheostomy securement systems. The systematic implementation of the MDRPIS may support more effective allocation of nursing resources and enhance patient safety by enabling the early identification and prevention of avoidable device-related pressure injuries. Furthermore, the findings indicate that an MDRPIS score of 16 or below represents a clinically meaningful threshold for initiating preventive interventions. © 2026 by the authors.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10409Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/healthcare14131942Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAydin Kahraman, Handan
dc.contributor.authorİpek Çoban, Gülay
dc.contributor.authorBozcu Kartal, Ebru
dc.date.accessioned2026-10-18T20:25:37.770503236Z
dc.date.available2026-10-18T20:25:37.770503236Z
dc.date.issued2026
dc.description.abstractObjective: This study aimed to evaluate the risk of medical device-related pressure injury (MDRPI) development among patients exposed to medical devices and to assess the clinical utility of the Medical Device-Related Pressure Injury Risk Assessment Scale (MDRPIS). Methods: This clinical assessment study included 132 patients receiving care in intensive care, palliative care, and home-care units. The MDRPIS total score ranges from 8 to 27, with scores of 8–12 indicating high risk, 13–21 indicating moderate risk, and 22–27 indicating low risk. The scale was used to assess MDRPI risk associated with life-sustaining medical devices. Its psychometric performance was evaluated through analyses of internal consistency, criterion validity against the Braden Scale, and diagnostic accuracy using receiver operating characteristic (ROC) analysis. Results: The MDRPIS demonstrated strong discriminative ability for identifying patients at risk of MDRPI, with an area under the curve (AUC) of 0.822. A cut-off score of ≤16 was identified as the optimal threshold for detecting high-risk patients. Patients with MDRPIS scores of 16 or lower had a significantly higher incidence of MDRPI than those classified as low risk (p < 0.001). Respiratory support devices, particularly non-invasive ventilation (NIV)/continuous positive airway pressure (CPAP) masks and tracheostomy flanges or securement devices, were identified as the most significant risk factors for injury development. The highest incidence of MDRPI was observed among patients in intensive care units, followed by those in palliative care and home-care settings, indicating a statistically significant concentration of device-related risk in high-acuity care environments (p < 0.05). Conclusions: Clinical settings, particularly intensive care and palliative care units, should incorporate the MDRPIS into routine risk assessment protocols to facilitate targeted preventive interventions, including prophylactic dressings and advanced fixation techniques for patients using high-risk devices such as NIV masks and tracheostomy securement systems. The systematic implementation of the MDRPIS may support more effective allocation of nursing resources and enhance patient safety by enabling the early identification and prevention of avoidable device-related pressure injuries. Furthermore, the findings indicate that an MDRPIS score of 16 or below represents a clinically meaningful threshold for initiating preventive interventions. © 2026 by the authors.
dc.description.sponsorshipThis research received no external funding.
dc.identifier.doi10.3390/healthcare14131942
dc.identifier.eissn2227-9032
dc.identifier.issn2227-9032
dc.identifier.issue13
dc.identifier.pmcidPMC13361182
dc.identifier.pmid42450951
dc.identifier.scopus2-s2.0-105045254935
dc.identifier.startpage1942
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10409
dc.identifier.volume14
dc.identifier.wosWOS:001818571700001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofHealthcare (Switzerland)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcritical care
dc.subjectmedical device-related pressure injury
dc.subjectmedical device-related pressure injury scale
dc.subjectnursing assessment
dc.subjectpatient safety
dc.subjectpressure injury
dc.subjectrisk assessment
dc.subjectadult
dc.subjectaged
dc.subjectarea under the curve
dc.subjectArticle
dc.subjectassisted ventilation
dc.subjectBraden Scale
dc.subjectclinical assessment
dc.subjectcontinuous positive airway pressure
dc.subjectcontrolled study
dc.subjectcriterion related validity
dc.subjectdiagnostic accuracy
dc.subjectdiagnostic test accuracy study
dc.subjectdiscriminant analysis
dc.subjectfemale
dc.subjecthigh risk patient
dc.subjecthome care
dc.subjecthuman
dc.subjectinjury risk
dc.subjectintensive care
dc.subjectintensive care unit
dc.subjectinternal consistency
dc.subjectLikert scale
dc.subjectmajor clinical study
dc.titleClinical Assessment of Medical Device–Related Pressure Injury Risk: Profiling Risk Levels in Patients Using Medical Devices
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.departmentDepartment of Nursing, Faculty of Health Sciences, Erzincan Binali Yıldırım University, Erzincan 24100, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)
rdl.wos.indexSocial Science Citation Index (SSCI)