A novel PVC-membrane potentiometric sensor based on molecularly imprinted polymer for the determination of rhodamine B

ArticleAçık Erişim

Özet

A rhodamine B (RH-B)-imprinted functional polymer was synthesized by free radical polymerization, utilizing RH-B as the template, methacrylic acid as the functional monomer, and ethyleneglycol dimethylacrylate as the cross-linker. The synthesized RH-B-imprinted polymer was characterized by FT-IR measurements. A novel RH-B-selective potentiometric poly(vinyl chloride) (PVC) membrane sensor was fabricated using this newly synthesized RH-B-imprinted functional polymer as the ionophore. Membrane optimization studies revealed that the most satisfactory membrane composition, yielding the best potentiometric parameters, comprised 32.0% (w/w) PVC, 64.0% (w/w) dibutyl phthalate, 3.0% (w/w) RH-B-imprinted polymer, and 1.0% (w/w) potassium tetrakis(4-chlorophenyl)borate. Further investigations into the potentiometric performance characteristics of the optimum composition demonstrated that the sensor exhibited a linear response to RH-B within the concentration range of 1.0 × 10–7 to 1.0 × 10–2 M with a detection limit of 1.0 × 10–8 M and a near Nernstian slope of 67.37 mV/decade. The sensor’s analytical proficiency was evidenced by its precise quantification of RH-B in RH-B-spiked rose-water samples, resulting in satisfactory recovery rates. © Springer-Verlag GmbH Austria, part of Springer Nature 2025.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10540Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s00706-025-03404-7Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorKaya, Nurcan
dc.contributor.authorColdur, Fatih
dc.contributor.authorHashemi-Moghaddam, Hamid
dc.contributor.authorSoylak, Mustafa
dc.date.accessioned2026-10-18T20:25:44.322483146Z
dc.date.available2026-10-18T20:25:44.322483146Z
dc.date.issued2026
dc.description.abstractA rhodamine B (RH-B)-imprinted functional polymer was synthesized by free radical polymerization, utilizing RH-B as the template, methacrylic acid as the functional monomer, and ethyleneglycol dimethylacrylate as the cross-linker. The synthesized RH-B-imprinted polymer was characterized by FT-IR measurements. A novel RH-B-selective potentiometric poly(vinyl chloride) (PVC) membrane sensor was fabricated using this newly synthesized RH-B-imprinted functional polymer as the ionophore. Membrane optimization studies revealed that the most satisfactory membrane composition, yielding the best potentiometric parameters, comprised 32.0% (w/w) PVC, 64.0% (w/w) dibutyl phthalate, 3.0% (w/w) RH-B-imprinted polymer, and 1.0% (w/w) potassium tetrakis(4-chlorophenyl)borate. Further investigations into the potentiometric performance characteristics of the optimum composition demonstrated that the sensor exhibited a linear response to RH-B within the concentration range of 1.0 × 10–7 to 1.0 × 10–2 M with a detection limit of 1.0 × 10–8 M and a near Nernstian slope of 67.37 mV/decade. The sensor’s analytical proficiency was evidenced by its precise quantification of RH-B in RH-B-spiked rose-water samples, resulting in satisfactory recovery rates. © Springer-Verlag GmbH Austria, part of Springer Nature 2025.
dc.identifier.doi10.1007/s00706-025-03404-7
dc.identifier.eissn1434-4475
dc.identifier.endpage11
dc.identifier.issn0026-9247
dc.identifier.issue1
dc.identifier.scopus2-s2.0-105021124802
dc.identifier.startpage1
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10540
dc.identifier.volume157
dc.identifier.wosWOS:001610154300001
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofMonatshefte fur Chemie
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMolecularly imprinted polymer
dc.subjectPotentiometric determination
dc.subjectPVC membrane electrode
dc.subjectRhodamine B determination
dc.subjectSelective electrode
dc.subjectAtom transfer radical polymerization
dc.subjectChemical sensors
dc.subjectFree radicals
dc.subjectMembranes
dc.subjectPolymer membrane electrodes
dc.subjectPotassium compounds
dc.subjectPotentiometers (electric measuring instruments)
dc.subjectPotentiometric sensors
dc.subjectRhodamine B
dc.subjectRhodium compounds
dc.subjectVoltammetry
dc.subjectFunctionals
dc.subjectPoly (vinyl chloride) membrane
dc.subjectPoly(vinyl chloride) membrane electrode
dc.subjectPotentiometrics
dc.subjectRhodamine-B
dc.subjectSelective electrodes
dc.subjectSynthesised
dc.subjectPolyvinyl chlorides
dc.titleA novel PVC-membrane potentiometric sensor based on molecularly imprinted polymer for the determination of rhodamine B
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)