Fabrication of a PVC Membrane Sensor Based on a HKUST-1 Metal-organic Framework for Direct Determination of Cysteamine in Pharmaceutical Formulation

ArticleAçık Erişim

Özet

Background: The most common use of cysteamine is the treatment of cystinosis. Excessive intake of cysteamine can lead to serious side effects and health complications. Therefore, the monitoring of cysteamine levels is highly significant. Objective: Several techniques have been developed to measure cysteamine accurately. Many of these methods are constrained by various limitations, including labor-intensive pre-treatment procedures, sophisticated equipment, skilled operators, and costly consumables. The present study aims to fabricate a cysteamine-selective potentiometric sensor based on HKUST-1 metal-organic framework exhibiting a wider linear range and more sensitive potentiometric responses compared to the ion pair-based cysteamine-selective sensor that was developed previously. Methods: A novel PVC membrane cysteamine-selective sensor was fabricated by coating the membrane cocktail consisting of poly(vinyl chloride), HKUST-1 metal-organic framework, plasticizer (o-nitrophenyloctylether), and ionic additive (potassium tetrakis (4-chlorophenyl) borate) onto the conductive solid contact surface. The potentiometric performance characteristics of the sensor were evaluated in detail. Results: The sensor exhibits a linear response to cysteamine concentration in the range of 1.0×10−6 M -1.0×10−2 M (R2=0.9958) with a slope of 51.5 mV/decade and a detection limit of 8.0×10-7 M. It operates effectively within a pH range of 3.9-5.7 and displays a rapid response time. Conclusion: Compared to the cysteamine-selective sensor available in the literature, the current sensor stands out with its wider linear operating range and lower detection limit. The sensor consistently yields reproducible and stable potentiometric responses towards cysteamine. The fabricated cysteamine-selective sensor effectively quantifies cysteamine content in pharmaceutical formulations. 2026, Bentham Science Publishers

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10611Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaya, Lutfi
dc.contributor.authorColdur, Fatih
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.date.accessioned2026-10-18T20:25:47.803087621Z
dc.date.available2026-10-18T20:25:47.803087621Z
dc.date.issued2026
dc.description.abstractBackground: The most common use of cysteamine is the treatment of cystinosis. Excessive intake of cysteamine can lead to serious side effects and health complications. Therefore, the monitoring of cysteamine levels is highly significant. Objective: Several techniques have been developed to measure cysteamine accurately. Many of these methods are constrained by various limitations, including labor-intensive pre-treatment procedures, sophisticated equipment, skilled operators, and costly consumables. The present study aims to fabricate a cysteamine-selective potentiometric sensor based on HKUST-1 metal-organic framework exhibiting a wider linear range and more sensitive potentiometric responses compared to the ion pair-based cysteamine-selective sensor that was developed previously. Methods: A novel PVC membrane cysteamine-selective sensor was fabricated by coating the membrane cocktail consisting of poly(vinyl chloride), HKUST-1 metal-organic framework, plasticizer (o-nitrophenyloctylether), and ionic additive (potassium tetrakis (4-chlorophenyl) borate) onto the conductive solid contact surface. The potentiometric performance characteristics of the sensor were evaluated in detail. Results: The sensor exhibits a linear response to cysteamine concentration in the range of 1.0×10−6 M -1.0×10−2 M (R2=0.9958) with a slope of 51.5 mV/decade and a detection limit of 8.0×10-7 M. It operates effectively within a pH range of 3.9-5.7 and displays a rapid response time. Conclusion: Compared to the cysteamine-selective sensor available in the literature, the current sensor stands out with its wider linear operating range and lower detection limit. The sensor consistently yields reproducible and stable potentiometric responses towards cysteamine. The fabricated cysteamine-selective sensor effectively quantifies cysteamine content in pharmaceutical formulations. 2026, Bentham Science Publishers
dc.identifier.doi10.2174/0115734110358615241210180129
dc.identifier.eissn1875-6727
dc.identifier.endpage370
dc.identifier.issn1573-4110
dc.identifier.issue2
dc.identifier.scopus2-s2.0-105031429880
dc.identifier.startpage361
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10611
dc.identifier.volume22
dc.identifier.wosWOS:001702746800011
dc.language.isoen
dc.publisherBentham Science Publishers
dc.relation.ispartofCurrent Analytical Chemistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCysteamine determination
dc.subjectelectrochemical sensors
dc.subjectHKUST-1
dc.subjectmetal-organic frameworks
dc.subjectpharmaceutical analysis
dc.subjectpotentiometric electrode
dc.subjectChemical sensors
dc.subjectCrystalline materials
dc.subjectDrug products
dc.subjectElectrodes
dc.subjectPolyvinyl chlorides
dc.subjectPotassium chloride
dc.subjectPotentiometers (electric measuring instruments)
dc.subjectPotentiometric sensors
dc.subjectVoltammetry
dc.subjectCysteamine
dc.subjectElectrochemicals
dc.subjectMetalorganic frameworks (MOFs)
dc.subjectPharmaceutical formulation
dc.subjectPotentiometrics
dc.subjectSelective sensors
dc.subjectFabrication