Comparison of artifact values of prosthodontic materials with 2 different cone beam computed tomography devices

ArticleAçık Erişim

Özet

Statement of problem: Prosthodontic materials may cause unexpected artifacts in cone beam computed tomography (CBCT) images, but studies quantifying these artifacts are sparse. Purpose: The purpose of this in vitro study was to compare the artifact expression of fixed prosthodontic materials with different CBCT devices. Material and methods: Ten prosthodontic materials (Co-Cr-Mo alloy, interim acrylic resin, polyetheretherketone, feldspathic ceramic, lithium disilicate glass-ceramic, zirconia-reinforced lithium silicate ceramic, zircon core, and 3 monolithic zirconias) were scanned with 2 CBCT devices. The materials were placed in polymethyl methacrylate resin to simulate clinical conditions. To assess the impact of the devices on artifacts, the gray values of 8 areas in each material image were analyzed. The data were analyzed with the Kruskal-Wallis and Wilcoxon Signed-Rank tests (α=.05). Results: Statistically significant differences were found in the artifact expression of the materials (P<.001) and between CBCT devices (P<.001). Conclusions: The artifact expression of polymeric and ceramic materials in CBCT images was less than that of other materials. The milliampere-second (mAs) value of CBCT devices had a significant impact on the artifact level. © 2025 Editorial Council for The Journal of Prosthetic Dentistry

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10845Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorNaralan, Muhammed Enes
dc.contributor.authorOzdogan, Alper
dc.contributor.authorGuller, Mustafa Taha
dc.contributor.authorMiloglu, Ozkan
dc.date.accessioned2026-10-18T20:25:58.349864685Z
dc.date.available2026-10-18T20:25:58.349864685Z
dc.date.issued2025
dc.description.abstractStatement of problem: Prosthodontic materials may cause unexpected artifacts in cone beam computed tomography (CBCT) images, but studies quantifying these artifacts are sparse. Purpose: The purpose of this in vitro study was to compare the artifact expression of fixed prosthodontic materials with different CBCT devices. Material and methods: Ten prosthodontic materials (Co-Cr-Mo alloy, interim acrylic resin, polyetheretherketone, feldspathic ceramic, lithium disilicate glass-ceramic, zirconia-reinforced lithium silicate ceramic, zircon core, and 3 monolithic zirconias) were scanned with 2 CBCT devices. The materials were placed in polymethyl methacrylate resin to simulate clinical conditions. To assess the impact of the devices on artifacts, the gray values of 8 areas in each material image were analyzed. The data were analyzed with the Kruskal-Wallis and Wilcoxon Signed-Rank tests (α=.05). Results: Statistically significant differences were found in the artifact expression of the materials (P<.001) and between CBCT devices (P<.001). Conclusions: The artifact expression of polymeric and ceramic materials in CBCT images was less than that of other materials. The milliampere-second (mAs) value of CBCT devices had a significant impact on the artifact level. © 2025 Editorial Council for The Journal of Prosthetic Dentistry
dc.identifier.doi10.1016/j.prosdent.2023.08.003
dc.identifier.eissn1097-6841
dc.identifier.endpage1573
dc.identifier.issn0022-3913
dc.identifier.issue6
dc.identifier.pmid37716900
dc.identifier.scopus2-s2.0-85171383889
dc.identifier.startpage1569
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10845
dc.identifier.volume133
dc.identifier.wosWOS:001551842500002
dc.language.isoen
dc.publisherElsevier Inc.
dc.relation.ispartofJournal of Prosthetic Dentistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectArtifacts
dc.subjectCeramics
dc.subjectCone-Beam Computed Tomography
dc.subjectDental Materials
dc.subjectHumans
dc.subjectIn Vitro Techniques
dc.subjectZirconium
dc.subjectdental material
dc.subjectzirconium oxide
dc.subjectartifact
dc.subjectchemistry
dc.subjectcomparative study
dc.subjectcone beam computed tomography
dc.subjectdevices
dc.subjecthuman
dc.subjectin vitro study
dc.subjectprocedures
dc.titleComparison of artifact values of prosthodontic materials with 2 different cone beam computed tomography devices
dc.typeArticle
dspace.entity.typePublication