Comparison of artifact values of prosthodontic materials with 2 different cone beam computed tomography devices
Özet
Statement of problem: Prosthodontic materials may cause unexpected artifacts in cone beam computed tomography (CBCT) images, but studies quantifying these artifacts are sparse. Purpose: The purpose of this in vitro study was to compare the artifact expression of fixed prosthodontic materials with different CBCT devices. Material and methods: Ten prosthodontic materials (Co-Cr-Mo alloy, interim acrylic resin, polyetheretherketone, feldspathic ceramic, lithium disilicate glass-ceramic, zirconia-reinforced lithium silicate ceramic, zircon core, and 3 monolithic zirconias) were scanned with 2 CBCT devices. The materials were placed in polymethyl methacrylate resin to simulate clinical conditions. To assess the impact of the devices on artifacts, the gray values of 8 areas in each material image were analyzed. The data were analyzed with the Kruskal-Wallis and Wilcoxon Signed-Rank tests (α=.05). Results: Statistically significant differences were found in the artifact expression of the materials (P<.001) and between CBCT devices (P<.001). Conclusions: The artifact expression of polymeric and ceramic materials in CBCT images was less than that of other materials. The milliampere-second (mAs) value of CBCT devices had a significant impact on the artifact level. © 2025 Editorial Council for The Journal of Prosthetic Dentistry
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Naralan, Muhammed Enes | |
| dc.contributor.author | Ozdogan, Alper | |
| dc.contributor.author | Guller, Mustafa Taha | |
| dc.contributor.author | Miloglu, Ozkan | |
| dc.date.accessioned | 2026-10-18T20:25:58.349864685Z | |
| dc.date.available | 2026-10-18T20:25:58.349864685Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | Statement of problem: Prosthodontic materials may cause unexpected artifacts in cone beam computed tomography (CBCT) images, but studies quantifying these artifacts are sparse. Purpose: The purpose of this in vitro study was to compare the artifact expression of fixed prosthodontic materials with different CBCT devices. Material and methods: Ten prosthodontic materials (Co-Cr-Mo alloy, interim acrylic resin, polyetheretherketone, feldspathic ceramic, lithium disilicate glass-ceramic, zirconia-reinforced lithium silicate ceramic, zircon core, and 3 monolithic zirconias) were scanned with 2 CBCT devices. The materials were placed in polymethyl methacrylate resin to simulate clinical conditions. To assess the impact of the devices on artifacts, the gray values of 8 areas in each material image were analyzed. The data were analyzed with the Kruskal-Wallis and Wilcoxon Signed-Rank tests (α=.05). Results: Statistically significant differences were found in the artifact expression of the materials (P<.001) and between CBCT devices (P<.001). Conclusions: The artifact expression of polymeric and ceramic materials in CBCT images was less than that of other materials. The milliampere-second (mAs) value of CBCT devices had a significant impact on the artifact level. © 2025 Editorial Council for The Journal of Prosthetic Dentistry | |
| dc.identifier.doi | 10.1016/j.prosdent.2023.08.003 | |
| dc.identifier.eissn | 1097-6841 | |
| dc.identifier.endpage | 1573 | |
| dc.identifier.issn | 0022-3913 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pmid | 37716900 | |
| dc.identifier.scopus | 2-s2.0-85171383889 | |
| dc.identifier.startpage | 1569 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/10845 | |
| dc.identifier.volume | 133 | |
| dc.identifier.wos | WOS:001551842500002 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Inc. | |
| dc.relation.ispartof | Journal of Prosthetic Dentistry | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Artifacts | |
| dc.subject | Ceramics | |
| dc.subject | Cone-Beam Computed Tomography | |
| dc.subject | Dental Materials | |
| dc.subject | Humans | |
| dc.subject | In Vitro Techniques | |
| dc.subject | Zirconium | |
| dc.subject | dental material | |
| dc.subject | zirconium oxide | |
| dc.subject | artifact | |
| dc.subject | chemistry | |
| dc.subject | comparative study | |
| dc.subject | cone beam computed tomography | |
| dc.subject | devices | |
| dc.subject | human | |
| dc.subject | in vitro study | |
| dc.subject | procedures | |
| dc.title | Comparison of artifact values of prosthodontic materials with 2 different cone beam computed tomography devices | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 2 | |
| rdl.citation.wos | 2 | |
| rdl.department | Lecturer, Department of Dentistry Services, Vocational School of Health Services, Erzincan Binali Yıldırım University, Erzincan, Turkey. Electronic address: dt.mtguller@gmail.com. | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |