Single-Phase Blood Flow in a Stenosed Coronary Artery: A Clinical Model-Based Experimental and Numerical Study

ArticleAçık Erişim

Özet

This study aims to develop an experimental platform that emulates the human cardiovascular system to investigate the effects of varying pulse rates and fluid properties on pressure drop, peristaltic pump output pressure, and power consumption. To support the experimental findings, computational fluid dynamics (CFD) simulations were conducted to analyze single-phase blood flow dynamics. Idealized arterial geometries representing healthy (0% stenosis) and diseased (65% stenosis) conditions were reconstructed from computed tomography (CT) images. A non-Newtonian blood-mimicking fluid (XSCN) was formulated to better replicate the rheological behavior of blood, while distilled water was used as the Newtonian reference fluid. Experiments were conducted at six different pulse rates: 72, 84, 96, 114, 132, and 156 beats per minute (bpm). The experimental setup was replicated in a virtual environment using ANSYS Fluent to simulate flow behavior under identical boundary conditions. The results demonstrate that increasing pulse rate leads to an increase in pressure drop (ΔP), pump output pressure, and power consumption for both arterial models. These effects were more pronounced in the stenosed artery due to flow constriction. Elevated turbulence intensity was observed at higher pulse rates, with notable differences between Newtonian and non-Newtonian fluids, particularly in terms of flow resistance and shear-dependent viscosity. Power consumption was found to be directly correlated with fluid viscosity, which varied with shear rate in the non-Newtonian fluid. The 65% stenosed model consistently exhibited higher pressure drops and flow irregularities. Fractional flow reserve (FFR) analysis confirmed that a 65% luminal narrowing poses significant hemodynamic risk. The highest wall shear stress (WSS) values were localized in the stenotic region, contributing to disturbed flow patterns and increased turbulence downstream. The non-Newtonian fluid model revealed that WSS was more sensitive to flow alterations, emphasizing the role of shear-dependent viscosity in vascular hemodynamics. These findings underscore the critical influence of hemodynamic parameters—such as pulse rate, viscosity, and arterial geometry—on cardiovascular performance. The study further highlights the detrimental impact of arterial stenosis on blood flow behavior and energy expenditure, with implications for clinical diagnosis and treatment planning in cardiovascular diseases. © 2025 John Wiley & Sons Ltd.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10855Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/cnm.70102Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYildirim, Orhan
dc.contributor.authorKaragoz, Sendogan
dc.contributor.authorSonmez, Fatin
dc.contributor.authorFirat, Ilker
dc.date.accessioned2026-10-18T20:25:58.816515084Z
dc.date.available2026-10-18T20:25:58.816515084Z
dc.date.issued2025
dc.description.abstractThis study aims to develop an experimental platform that emulates the human cardiovascular system to investigate the effects of varying pulse rates and fluid properties on pressure drop, peristaltic pump output pressure, and power consumption. To support the experimental findings, computational fluid dynamics (CFD) simulations were conducted to analyze single-phase blood flow dynamics. Idealized arterial geometries representing healthy (0% stenosis) and diseased (65% stenosis) conditions were reconstructed from computed tomography (CT) images. A non-Newtonian blood-mimicking fluid (XSCN) was formulated to better replicate the rheological behavior of blood, while distilled water was used as the Newtonian reference fluid. Experiments were conducted at six different pulse rates: 72, 84, 96, 114, 132, and 156 beats per minute (bpm). The experimental setup was replicated in a virtual environment using ANSYS Fluent to simulate flow behavior under identical boundary conditions. The results demonstrate that increasing pulse rate leads to an increase in pressure drop (ΔP), pump output pressure, and power consumption for both arterial models. These effects were more pronounced in the stenosed artery due to flow constriction. Elevated turbulence intensity was observed at higher pulse rates, with notable differences between Newtonian and non-Newtonian fluids, particularly in terms of flow resistance and shear-dependent viscosity. Power consumption was found to be directly correlated with fluid viscosity, which varied with shear rate in the non-Newtonian fluid. The 65% stenosed model consistently exhibited higher pressure drops and flow irregularities. Fractional flow reserve (FFR) analysis confirmed that a 65% luminal narrowing poses significant hemodynamic risk. The highest wall shear stress (WSS) values were localized in the stenotic region, contributing to disturbed flow patterns and increased turbulence downstream. The non-Newtonian fluid model revealed that WSS was more sensitive to flow alterations, emphasizing the role of shear-dependent viscosity in vascular hemodynamics. These findings underscore the critical influence of hemodynamic parameters—such as pulse rate, viscosity, and arterial geometry—on cardiovascular performance. The study further highlights the detrimental impact of arterial stenosis on blood flow behavior and energy expenditure, with implications for clinical diagnosis and treatment planning in cardiovascular diseases. © 2025 John Wiley & Sons Ltd.
dc.description.sponsorshipFunding text 1: The authors would like to express their gratitude to Atat\u00FCrk University for providing both the laboratory facilities used in the experiments and access to the CFD simulation software ANSYS\u2010Fluent. This study was supported by the Scientific Research Projects Coordinatorship of Atat\u00FCrk University under project number FCD\u20102019\u20107316. This paper is based on the single\u2010phase section of the doctoral research conducted by Orhan YILDIRIM. The authors extend their special thanks to Orhan YILDIRIM for his valuable contributions. ; Funding text 2: This work was supported by Atat\u00FCrk University, FCD\u20102019\u20107316. Funding:
dc.identifier.doi10.1002/cnm.70102
dc.identifier.eissn2040-7947
dc.identifier.issn2040-7939
dc.identifier.issue10
dc.identifier.pmid41039643
dc.identifier.scopus2-s2.0-105017753587
dc.identifier.startpagee70102
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10855
dc.identifier.volume41
dc.identifier.wosWOS:001605957400002
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofInternational Journal for Numerical Methods in Biomedical Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectblood flow
dc.subjectCasson model
dc.subjectcoronary arteries
dc.subjectwall shear stress
dc.subjectBlood Flow Velocity
dc.subjectComputer Simulation
dc.subjectCoronary Stenosis
dc.subjectCoronary Vessels
dc.subjectHemodynamics
dc.subjectHumans
dc.subjectHydrodynamics
dc.subjectModels, Cardiovascular
dc.subjectBlood
dc.subjectBlood vessels
dc.subjectComputational fluid dynamics
dc.subjectComputerized tomography
dc.subjectDrops
dc.subjectElectric power utilization
dc.subjectFlow measurement
dc.subjectFluid Power
dc.subjectHeart
dc.subjectNewtonian flow
dc.subjectNon Newtonian flow
dc.subjectNon Newtonian liquids
dc.subjectPressure drop
dc.subjectRheology
dc.subjectShear deformation
dc.subjectShear flow
dc.subjectShear viscosity
dc.subjectVirtual reality
dc.titleSingle-Phase Blood Flow in a Stenosed Coronary Artery: A Clinical Model-Based Experimental and Numerical Study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.wos3
rdl.departmentIlic Dursun Yildirim Vocational School, Erzincan Binali Yildirim University, Erzincan, Turkey.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)