Effect of cavity depth on degree of conversion and microhardness of low-shrinkage resin composites

ArticleAçık Erişim

Özet

Background: The study aimed to investigate the effect of different cavity depths on the degree of conversion (DC) and surface microhardness (MH) of low-shrinkage resin composites. Methods: Three low-shrinkage resin composites (Clearfil Majestry Posterior/CMP, Beautifil II LS/BL, Charisma Diamond/CD) and one conventional nanohybrid resin composite (Filtek Z550/FZ) as control were evaluated. For each composite material, a total of 12 disc-shaped samples were prepared using plastic molds with two different depths (2 mm and 4 mm) (n = 6). The same sample preparation protocol was applied for the DC and MH tests, and a total of 96 samples were prepared, 48 for each test. Resin composites filled into molds with the incremental technique were cured with LED light unit only from the top surface. DC was determined by Fourier transform infrared (FTIR) spectroscopy; MH was determined using the Vickers hardness tester. Data were statistically analyzed using Robust and two-way variance analyses (p < 0.05). Results: For all resin composites, there was no significantly difference in DC and MH between the 2 mm and 4 mm cavity depths. BL showed the highest DC values at both cavity depths, while CD showed the lowest (p < 0.001). At both cavity depths, the highest MH values on bottom-top surfaces ​​were obtained in CMP, while the lowest ​​were in BL. The top surface MH values ​​were higher in all resin composites than the bottom surfaces. Conclusions: Increasing cavity depth may not negatively affect the DC and MH of low-shrinkage resin composites. Moreover, resin composite material formulations may have a higher potential effect on these parameters. Clinical trial number: Not applicable. © The Author(s) 2025.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11002Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1186/s12903-025-06511-3Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorGömleksiz, Seda
dc.contributor.authorGömleksiz, Oğuzhan
dc.date.accessioned2026-10-18T20:26:06.656110169Z
dc.date.available2026-10-18T20:26:06.656110169Z
dc.date.issued2025
dc.description.abstractBackground: The study aimed to investigate the effect of different cavity depths on the degree of conversion (DC) and surface microhardness (MH) of low-shrinkage resin composites. Methods: Three low-shrinkage resin composites (Clearfil Majestry Posterior/CMP, Beautifil II LS/BL, Charisma Diamond/CD) and one conventional nanohybrid resin composite (Filtek Z550/FZ) as control were evaluated. For each composite material, a total of 12 disc-shaped samples were prepared using plastic molds with two different depths (2 mm and 4 mm) (n = 6). The same sample preparation protocol was applied for the DC and MH tests, and a total of 96 samples were prepared, 48 for each test. Resin composites filled into molds with the incremental technique were cured with LED light unit only from the top surface. DC was determined by Fourier transform infrared (FTIR) spectroscopy; MH was determined using the Vickers hardness tester. Data were statistically analyzed using Robust and two-way variance analyses (p < 0.05). Results: For all resin composites, there was no significantly difference in DC and MH between the 2 mm and 4 mm cavity depths. BL showed the highest DC values at both cavity depths, while CD showed the lowest (p < 0.001). At both cavity depths, the highest MH values on bottom-top surfaces ​​were obtained in CMP, while the lowest ​​were in BL. The top surface MH values ​​were higher in all resin composites than the bottom surfaces. Conclusions: Increasing cavity depth may not negatively affect the DC and MH of low-shrinkage resin composites. Moreover, resin composite material formulations may have a higher potential effect on these parameters. Clinical trial number: Not applicable. © The Author(s) 2025.
dc.description.sponsorshipThis research was supported by Erzincan Binali Y\u0131ld\u0131r\u0131m University Scientific Research Projects with the project number TSA-2023-889.
dc.identifier.doi10.1186/s12903-025-06511-3
dc.identifier.issn1472-6831
dc.identifier.issue1
dc.identifier.pmcidPMC12232005
dc.identifier.pmid40615874
dc.identifier.scopus2-s2.0-105010134869
dc.identifier.startpage1091
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11002
dc.identifier.volume25
dc.identifier.wosWOS:001523058100011
dc.language.isoen
dc.publisherBioMed Central Ltd
dc.relation.ispartofBMC Oral Health
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComposite resins
dc.subjectDegree of conversion
dc.subjectHardness
dc.subjectPolymerization
dc.subjectBisphenol A-Glycidyl Methacrylate
dc.subjectDental Cavity Preparation
dc.subjectDental Materials
dc.subjectHumans
dc.subjectMaterials Testing
dc.subjectNanocomposites
dc.subjectSpectroscopy, Fourier Transform Infrared
dc.subjectSurface Properties
dc.subjectBeautifil composite resin
dc.subjectbisphenol A bis(2 hydroxypropyl) ether dimethacrylate
dc.subjectCharisma composite resin
dc.subjectclearfil majesty
dc.subjectdental material
dc.subjectFiltek Z550
dc.subjectnanocomposite
dc.subjectresin
dc.subjectchemistry
dc.subjectclassification
dc.subjectcomparative study
dc.subjectdental surgery
dc.subjectFourier transform infrared spectroscopy
dc.subjecthuman
dc.subjectprocedures
dc.subjectsurface property
dc.titleEffect of cavity depth on degree of conversion and microhardness of low-shrinkage resin composites
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos4
rdl.departmentDepartment of Restorative Dentistry, Faculty of Dentistry, Erzincan Binali Yıldırım University, Erzincan, Turkey. sedaozkanoglu1@gmail.com. | Department of Prosthodontics, Faculty of Dentistry, Erzincan Binali Yıldırım University, Erzincan, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)