All-Solid-State Potentiometric Sensor Based on Carbon Paste Composite for the Selective Determination of Iodide Ions

ArticleAçık Erişim

Özet

Abstract: In the current study, a potentiometric all-solid-state composite ion-selective electrode for the determination of iodide ions is described. The synthesized salicylaldehyde thiosemicarbazone-mercury(II) complex (SATSC-Hg(II)) (1 : 1) was applied as the electroactive material in the electrode structure. Various composite ion-selective electrodes were prepared with different compositions, including SATSC-Hg(II), graphite, multi-walled carbon nanotubes (MWCNTs), ionic additives, and some mediators (various plasticizers or paraffin oil) to identify the most effective composite sensing layer composition exhibiting satisfactory potentiometric characteristics. The sensing layer composition consisting of 10 mg SATSC-Hg(II) complex, 26 mg dioctyl phthalate plasticizer, 5 mg MWCNTs, 4 mg methyltrioctylammonium chloride, and 65 mg graphite yielded the most favorable potentiometric performance properties. The electrode demonstrated a linear operating range of 1.0 × 10–5 to 0.1 M, a slope value of 55.2 ± 0.2 mV/decade, a detection limit of (9.0 ± 0.2) × 10–6 M, a pH operating range of 4–8, and a response time of approximately 60 s. The proposed electrode also displayed reproducible, stable, and selective potentiometric response to iodide ions. The analytical application of the electrode involved its use as an indicator electrode in the titration of iodide ions in synthetic solutions and for the determination of KI content in a pharmaceutical used for the treatment of goiter by the multiple standard addition method. Compared to polymer membrane electrodes, the renewability and reusability of the sensing surface of the proposed electrode, its suitability for miniaturization, and its robust structure offer significant advantages. © Pleiades Publishing, Ltd. 2025.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11159Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1134/s1061934824702009Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYilmaz, Semra
dc.contributor.authorColdur, Fatih
dc.date.accessioned2026-10-18T20:26:15.376662894Z
dc.date.available2026-10-18T20:26:15.376662894Z
dc.date.issued2025
dc.description.abstractAbstract: In the current study, a potentiometric all-solid-state composite ion-selective electrode for the determination of iodide ions is described. The synthesized salicylaldehyde thiosemicarbazone-mercury(II) complex (SATSC-Hg(II)) (1 : 1) was applied as the electroactive material in the electrode structure. Various composite ion-selective electrodes were prepared with different compositions, including SATSC-Hg(II), graphite, multi-walled carbon nanotubes (MWCNTs), ionic additives, and some mediators (various plasticizers or paraffin oil) to identify the most effective composite sensing layer composition exhibiting satisfactory potentiometric characteristics. The sensing layer composition consisting of 10 mg SATSC-Hg(II) complex, 26 mg dioctyl phthalate plasticizer, 5 mg MWCNTs, 4 mg methyltrioctylammonium chloride, and 65 mg graphite yielded the most favorable potentiometric performance properties. The electrode demonstrated a linear operating range of 1.0 × 10–5 to 0.1 M, a slope value of 55.2 ± 0.2 mV/decade, a detection limit of (9.0 ± 0.2) × 10–6 M, a pH operating range of 4–8, and a response time of approximately 60 s. The proposed electrode also displayed reproducible, stable, and selective potentiometric response to iodide ions. The analytical application of the electrode involved its use as an indicator electrode in the titration of iodide ions in synthetic solutions and for the determination of KI content in a pharmaceutical used for the treatment of goiter by the multiple standard addition method. Compared to polymer membrane electrodes, the renewability and reusability of the sensing surface of the proposed electrode, its suitability for miniaturization, and its robust structure offer significant advantages. © Pleiades Publishing, Ltd. 2025.
dc.identifier.doi10.1134/s1061934824702009
dc.identifier.eissn1608-3199
dc.identifier.endpage552
dc.identifier.issn1061-9348
dc.identifier.issue3
dc.identifier.scopus2-s2.0-105004360693
dc.identifier.startpage540
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11159
dc.identifier.volume80
dc.identifier.wosWOS:001483077000009
dc.language.isoen
dc.publisherPleiades Publishing
dc.relation.ispartofJournal of Analytical Chemistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectall-solid-state electrode
dc.subjectiodide determination
dc.subjectiodide selective electrode
dc.subjectmercury(II)-salicylaldehyde thiosemicarbazone complex
dc.subjectpharmaceutical analysis
dc.subjectCarbon carbon composites
dc.subjectIon selective electrodes
dc.subjectMultiwalled carbon nanotubes (MWCN)
dc.subjectPolymer membrane electrodes
dc.subjectPotentiometers (electric measuring instruments)
dc.subjectPotentiometers (resistors)
dc.subjectReusability
dc.subjectAll-solid state
dc.subjectSalicylaldehyde thiosemicarbazone
dc.subjectSelective electrodes
dc.subjectSolid-state electrodes
dc.subjectThiosemicarbazone complexes
dc.subjectPotentiometric sensors
dc.titleAll-Solid-State Potentiometric Sensor Based on Carbon Paste Composite for the Selective Determination of Iodide Ions
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.wos2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)