The effect of internal blinds on thermal comfort: An experimental analysis in an office room with radiant panels

ArticleAçık Erişim

Özet

This study investigated the impact of two types of internal blinds on the indoor thermal environment of a highly glazed office room in Istanbul during summer. The research examined four configurations: (i) no blinds, (ii) roller blinds, (iii) layered roller blinds in night mode and (iv) layered roller blinds in day mode. Measurements of air velocity, average radiation temperature, air temperature and relative humidity were conducted to assess thermal comfort. The findings revealed that internal blinds significantly influence thermal comfort in radiantly cooled office spaces during summer. Without blinds, the indoor environment only met ISO 7730 comfort category C, with average predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) values of 0.6 and 12.5%, respectively. However, with internal blinds, comfort categories A and B were achieved, resulting in improved thermal comfort levels, with average PMV and PPD values ranging from 0.2 to 0.3 and 6% to 7.5%, respectively. Roller blinds, in particular, proved highly effective in enhancing thermal comfort and reducing mean radiant and indoor air temperatures in highly glazed radiant cooling offices. This demonstrated their energy-efficient potential for improving indoor thermal comfort. © The Author(s) 2024.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11358Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/1420326x241243003Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDogan, Ahmet
dc.contributor.authorKayaci, Nurullah
dc.contributor.authorDemir, Hakan
dc.date.accessioned2026-10-18T20:26:25.340258619Z
dc.date.available2026-10-18T20:26:25.340258619Z
dc.date.issued2024
dc.description.abstractThis study investigated the impact of two types of internal blinds on the indoor thermal environment of a highly glazed office room in Istanbul during summer. The research examined four configurations: (i) no blinds, (ii) roller blinds, (iii) layered roller blinds in night mode and (iv) layered roller blinds in day mode. Measurements of air velocity, average radiation temperature, air temperature and relative humidity were conducted to assess thermal comfort. The findings revealed that internal blinds significantly influence thermal comfort in radiantly cooled office spaces during summer. Without blinds, the indoor environment only met ISO 7730 comfort category C, with average predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) values of 0.6 and 12.5%, respectively. However, with internal blinds, comfort categories A and B were achieved, resulting in improved thermal comfort levels, with average PMV and PPD values ranging from 0.2 to 0.3 and 6% to 7.5%, respectively. Roller blinds, in particular, proved highly effective in enhancing thermal comfort and reducing mean radiant and indoor air temperatures in highly glazed radiant cooling offices. This demonstrated their energy-efficient potential for improving indoor thermal comfort. © The Author(s) 2024.
dc.description.sponsorshipThe author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This study received financial support from Yildiz Technical University through the BAP program, with the grant number FBA-2019-3703. We extend our sincere appreciation to Yildiz Technical University for their invaluable funding assistance in facilitating this research.
dc.identifier.doi10.1177/1420326x241243003
dc.identifier.eissn1423-0070
dc.identifier.endpage1414
dc.identifier.issn1420-326X
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85189643035
dc.identifier.startpage1397
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11358
dc.identifier.volume33
dc.identifier.wosWOS:001193818100001
dc.language.isoen
dc.publisherSAGE Publications Ltd
dc.relation.ispartofIndoor and Built Environment
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGround source heat pump
dc.subjectIndoor thermal environment
dc.subjectRadiant cooling system
dc.subjectRoller blind
dc.subjectThe predicted mean vote and percentage of dissatisfied
dc.subjectair quality
dc.subjectair temperature
dc.subjectair velocity
dc.subjectambient air
dc.subjectArticle
dc.subjectcomfort
dc.subjectenvironmental temperature
dc.subjecthuman
dc.subjecthuman experiment
dc.subjecthumidity
dc.subjectindoor environment
dc.subjectpredicted mean vote
dc.subjectpredicted percentage of dissatisfied
dc.subjectpredictive value
dc.subjectsolar radiation
dc.subjectsummer
dc.subjectthermal comfort
dc.subjectTurkey (republic)
dc.subjectvelocity
dc.titleThe effect of internal blinds on thermal comfort: An experimental analysis in an office room with radiant panels
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus3
rdl.citation.wos3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)