A novel artificial intelligence-based hybrid system to improve breast cancer detection using DCE-MRI

ArticleAçık Erişim

Özet

The interpretation of breast magnetic resonance imaging (MRI) in the healthcare field depends on the good knowledge and experience of radiologists. Recent developments in artificial intelligence (AI) have shown advances in the field of radiology. However, the desired levels have not been reached in the field of radiology yet. In this study, a novel model structure is proposed to characterize the diagnostic performance of AI technology for individual breast dynamic contrast material–enhanced (DCE) MRI sequences. In the proposed model structure, Inception-v3, EfficientNet-B3, and DenseNet-201 models were used as hybrids together with the Yolo-v3 algorithm to detect breast and cancer regions. In the proposed model, DCE-MRI sequences (T2, ADC, Diffusion, Non-Contrast Fat Non-Suppressed T1, Non-Contrast Fat Suppressed T1, Contrast Fat Suppressed T1, and Subtraction T1) were evaluated separately and validation was made, thus providing a unique perspective. According to the validation results, the model structure with the best performance was determined as Yolo-v3 + DenseNet-201. With this model structure, 92.41% accuracy, 0.5936 loss, 92.44% sensitivity, and 92.44% specificity rates were obtained. In addition, it was determined that the results obtained without using contrast material in the best model were 91.53% accuracy, 0.9646 loss, 92.19% sensitivity, and 92.19% specificity. Therefore, it is predicted that the need for contrast material use can be reduced with the help of this model structure. © 2024 Polska Akademia Nauk. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11844Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.24425/bpasts.2024.149172Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkgül, Ismail
dc.contributor.authorKaya, Volkan
dc.contributor.authorKaravaş, Erdal
dc.contributor.authorAydin, Sonay
dc.contributor.authorBaran, Ahmet
dc.date.accessioned2026-10-18T20:26:50.417331591Z
dc.date.available2026-10-18T20:26:50.417331591Z
dc.date.issued2024
dc.description.abstractThe interpretation of breast magnetic resonance imaging (MRI) in the healthcare field depends on the good knowledge and experience of radiologists. Recent developments in artificial intelligence (AI) have shown advances in the field of radiology. However, the desired levels have not been reached in the field of radiology yet. In this study, a novel model structure is proposed to characterize the diagnostic performance of AI technology for individual breast dynamic contrast material–enhanced (DCE) MRI sequences. In the proposed model structure, Inception-v3, EfficientNet-B3, and DenseNet-201 models were used as hybrids together with the Yolo-v3 algorithm to detect breast and cancer regions. In the proposed model, DCE-MRI sequences (T2, ADC, Diffusion, Non-Contrast Fat Non-Suppressed T1, Non-Contrast Fat Suppressed T1, Contrast Fat Suppressed T1, and Subtraction T1) were evaluated separately and validation was made, thus providing a unique perspective. According to the validation results, the model structure with the best performance was determined as Yolo-v3 + DenseNet-201. With this model structure, 92.41% accuracy, 0.5936 loss, 92.44% sensitivity, and 92.44% specificity rates were obtained. In addition, it was determined that the results obtained without using contrast material in the best model were 91.53% accuracy, 0.9646 loss, 92.19% sensitivity, and 92.19% specificity. Therefore, it is predicted that the need for contrast material use can be reduced with the help of this model structure. © 2024 Polska Akademia Nauk. All rights reserved.
dc.description.sponsorshipThanks to Erzincan Binali Y & imath;ld & imath;r & imath;m University for supporting this publication with dataset.
dc.identifier.doi10.24425/bpasts.2024.149172
dc.identifier.eissn2300-1917
dc.identifier.issn0239-7528
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85191899108
dc.identifier.startpagee149172
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11844
dc.identifier.volume72
dc.identifier.wosWOS:001283665700001
dc.language.isoen
dc.publisherPolska Akademia Nauk
dc.relation.ispartofBulletin of the Polish Academy of Sciences: Technical Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectartificial intelligence
dc.subjectartificial neural network
dc.subjectbreast cancer detection
dc.subjectclassification
dc.subjectDCE-MRI
dc.subjectdeep learning
dc.subjectDiseases
dc.subjectHybrid systems
dc.subjectMedical imaging
dc.subjectNeural networks
dc.subjectRadiology
dc.subjectArtificial intelligence technologies
dc.subjectBreast magnetic-resonance imaging
dc.subjectContrast material
dc.subjectDiagnostic performance
dc.subjectDynamic contrast
dc.subjectDynamic contrast material–enhanced-magnetic resonance imaging
dc.subjectImaging sequence
dc.subjectKnowledge and experience
dc.subjectMagnetic resonance imaging
dc.titleA novel artificial intelligence-based hybrid system to improve breast cancer detection using DCE-MRI
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.wos1
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)