Corrigendum to “The effectiveness of blood routine parameters and some biomarkers as a potential diagnostic tool in the diagnosis and prognosis of Covid-19 disease” [Int. Immunopharmacol. 98 (2021) 107838] (International Immunopharmacology (2021) 98, (S1567576921004744), (10.1016/j.intimp.2021.107838))

CorrectionAçık Erişim

Özet

The authors inadvertently forgot to indicate some application steps regarding the CHAID analysis method applied in the statistical analysis (Section 2.8) section of the original article. Also, in Tables 4 and 6, there were misspelled numbers in the OR (odds-ratio) and confidence intervals of some variables. These corrections do not affect the interpretation of the data or the conclusions drawn. The authors apologize to the journal and readers for these unintentional errors. The significance levels for the significant p values (p = 0.000,) given in all tables were accepted as *p < 0.05, **p < 0.01, ***p < 0.001. These importance levels are specified in the table explanations in the original article. We felt the need to reiterate. The following statistical model specifications and stopping criteria were applied in the CHAID decision tree analysis: (1) Significant level for separation nodes was determined as p < 0.05.(2) The Bonferroni method was used to obtain significant correction values.(3) The minimum change in expected cell frequencies was 0.001.(4) Pearson χ2 independence test was used to determine the relationships between independent (explanatory) variables.(5) Model depth is set to maximum.(6) A 10-fold cross-validation was used to evaluate the tree structure and(7) Misclassification risk was calculated as a measure of model reliability. Table 4.[Table presented] Table 6.[Table presented] © 2023 Elsevier B.V.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11922Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHuyut, Mehmet Tahir
dc.contributor.authorİlkbahar, Fatih
dc.date.accessioned2026-10-18T20:26:54.128724157Z
dc.date.available2026-10-18T20:26:54.128724157Z
dc.date.issued2023
dc.description.abstractThe authors inadvertently forgot to indicate some application steps regarding the CHAID analysis method applied in the statistical analysis (Section 2.8) section of the original article. Also, in Tables 4 and 6, there were misspelled numbers in the OR (odds-ratio) and confidence intervals of some variables. These corrections do not affect the interpretation of the data or the conclusions drawn. The authors apologize to the journal and readers for these unintentional errors. The significance levels for the significant p values (p = 0.000,) given in all tables were accepted as *p < 0.05, **p < 0.01, ***p < 0.001. These importance levels are specified in the table explanations in the original article. We felt the need to reiterate. The following statistical model specifications and stopping criteria were applied in the CHAID decision tree analysis: (1) Significant level for separation nodes was determined as p < 0.05.(2) The Bonferroni method was used to obtain significant correction values.(3) The minimum change in expected cell frequencies was 0.001.(4) Pearson χ2 independence test was used to determine the relationships between independent (explanatory) variables.(5) Model depth is set to maximum.(6) A 10-fold cross-validation was used to evaluate the tree structure and(7) Misclassification risk was calculated as a measure of model reliability. Table 4.[Table presented] Table 6.[Table presented] © 2023 Elsevier B.V.
dc.identifier.doi10.1016/j.intimp.2023.110823
dc.identifier.eissn1878-1705
dc.identifier.issn1567-5769
dc.identifier.pmcidPMC11021335
dc.identifier.pmid37661504
dc.identifier.scopus2-s2.0-85169923412
dc.identifier.startpage110823
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11922
dc.identifier.volume123
dc.identifier.wosWOS:001083711100001
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofInternational Immunopharmacology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjecterratum
dc.titleCorrigendum to “The effectiveness of blood routine parameters and some biomarkers as a potential diagnostic tool in the diagnosis and prognosis of Covid-19 disease” [Int. Immunopharmacol. 98 (2021) 107838] (International Immunopharmacology (2021) 98, (S1567576921004744), (10.1016/j.intimp.2021.107838))
dc.typeCorrection
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.wos1
rdl.departmentErzincan Binali Yıldırım University, Faculty of Medicine, Department of Biostatistics and Medical Informatics, Erzincan, Turkey. Electronic address: tahir.huyut@erzincan.edu.tr.
rdl.oa.statusgreen
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)