Long-term lung perfusion changes related to COVID-19: a dual energy computed tomography study

ArticleAçık Erişim

Özet

PURPOSE Although the findings of acute new coronavirus disease (COVID-19) infection on dual-energy computed tomography (DECT) have recently been defined, the long-term changes in lung perfusion associated with COVID-19 pneumonia have not yet been clarified. We aimed to examine the long-term course of lung perfusion in COVID-19 pneumonia cases using DECT and to compare changes in lung perfusion to clinical and laboratory findings. METHODS On initial and follow-up DECT scans, the presence and extent of perfusion deficit (PD) and paren-chymal changes were assessed. The associations between PD presence and laboratory parameters, initial DECT severity score, and symptoms were evaluated. RESULTS The study population included 18 females and 26 males with an average age of 61.32 ± 11.3 years. Follow-up DECT examinations were performed after the mean of 83.12 ± 7.1 (80–94 days) days. PDs were detected on the follow-up DECT scans of 16 (36.3%) patients. These 16 patients also had ground-glass parenchymal lesions on the follow-up DECT scans. Patients with persistent lung PDs had significantly higher mean initial D-dimer, fibrinogen, and C-reactive protein values than patients without PDs. Patients with persistent PDs also had significantly higher rates of persistent symptoms. CONCLUSION Ground-glass opacities and lung PDs associated with COVID-19 pneumonia can persist for up to 80–90 days. Dual-energy computed tomography can be used to reveal long-term parenchymal and perfusion changes. Persistent PDs are commonly seen together with persistent COVID-19 symptoms. © 2023, Turkish Society of Radiology. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12300Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.5152/dir.2022.211090Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAydın, Sonay
dc.contributor.authorKaravaş, Erdal
dc.contributor.authorÜnver, Edhem
dc.contributor.authorŞenbil, Düzgün Can
dc.contributor.authorKantarcı, Mecit
dc.date.accessioned2026-10-18T20:27:12.845650358Z
dc.date.available2026-10-18T20:27:12.845650358Z
dc.date.issued2023
dc.description.abstractPURPOSE Although the findings of acute new coronavirus disease (COVID-19) infection on dual-energy computed tomography (DECT) have recently been defined, the long-term changes in lung perfusion associated with COVID-19 pneumonia have not yet been clarified. We aimed to examine the long-term course of lung perfusion in COVID-19 pneumonia cases using DECT and to compare changes in lung perfusion to clinical and laboratory findings. METHODS On initial and follow-up DECT scans, the presence and extent of perfusion deficit (PD) and paren-chymal changes were assessed. The associations between PD presence and laboratory parameters, initial DECT severity score, and symptoms were evaluated. RESULTS The study population included 18 females and 26 males with an average age of 61.32 ± 11.3 years. Follow-up DECT examinations were performed after the mean of 83.12 ± 7.1 (80–94 days) days. PDs were detected on the follow-up DECT scans of 16 (36.3%) patients. These 16 patients also had ground-glass parenchymal lesions on the follow-up DECT scans. Patients with persistent lung PDs had significantly higher mean initial D-dimer, fibrinogen, and C-reactive protein values than patients without PDs. Patients with persistent PDs also had significantly higher rates of persistent symptoms. CONCLUSION Ground-glass opacities and lung PDs associated with COVID-19 pneumonia can persist for up to 80–90 days. Dual-energy computed tomography can be used to reveal long-term parenchymal and perfusion changes. Persistent PDs are commonly seen together with persistent COVID-19 symptoms. © 2023, Turkish Society of Radiology. All rights reserved.
dc.identifier.doi10.5152/dir.2022.211090
dc.identifier.eissn1305-3612
dc.identifier.endpage108
dc.identifier.issn1305-3825
dc.identifier.issue1
dc.identifier.pmcidPMC10679602
dc.identifier.pmid36960546
dc.identifier.scopus2-s2.0-85147762777
dc.identifier.startpage103
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12300
dc.identifier.volume29
dc.identifier.wosWOS:000934079600012
dc.language.isoen
dc.publisherTurkish Society of Radiology
dc.relation.ispartofDiagnostic and Interventional Radiology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCOVID-19
dc.subjectDECT
dc.subjectfollow-up
dc.subjectlung
dc.subjectperfusion deficit
dc.subjectAged
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectPerfusion
dc.subjectThorax
dc.subjectTomography, X-Ray Computed
dc.subjectblood clotting factor 10a
dc.subjectC reactive protein
dc.subjectD dimer
dc.subjectenoxaparin
dc.subjectfibrinogen
dc.subjectiohexol
dc.subjectadult
dc.subjectarea under the curve
dc.subjectArticle
dc.subjectblood volume
dc.subjectclinical article
dc.subjectcontrolled study
dc.subjectcoronavirus disease 2019
dc.subjectcoughing
dc.subjectdiagnostic test accuracy study
dc.subjectdisease severity assessment
dc.subjectdual energy computed tomography
dc.titleLong-term lung perfusion changes related to COVID-19: a dual energy computed tomography study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus6
rdl.citation.trdizin2
rdl.citation.wos7
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentATATÜRK ÜNİVERSİTESİ
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)