Investigation of surface wettability, corrosion and tribocorrosion behavior of machined, etched, blasted and anodized Cp-Ti samples
Özet
Machined, etched, blasted, and anodized commercially pure titanium (Cp-Ti) samples were used in this study. The aim of this study is to examine the effects of the most applied surface treatments on Cp-Ti samples, which are preferred for use in biomedical applications, on surface wettability, corrosion, and tribocorrosion behaviors. It was observed that surface morphology had a significant effect on surface wettability. The best wettability was obtained from the anodized sample. In the samples whose corrosion and tribocorrosion performances were examined, it was observed that the highest resistance was obtained from the anodized sample, compared to other samples. Graphical abstract: [Figure not available: see fulltext.]. © 2023, The Author(s), under exclusive licence to The Materials Research Society.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Acar, M.T. | |
| dc.date.accessioned | 2026-10-18T20:27:17.836533206Z | |
| dc.date.available | 2026-10-18T20:27:17.836533206Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | Machined, etched, blasted, and anodized commercially pure titanium (Cp-Ti) samples were used in this study. The aim of this study is to examine the effects of the most applied surface treatments on Cp-Ti samples, which are preferred for use in biomedical applications, on surface wettability, corrosion, and tribocorrosion behaviors. It was observed that surface morphology had a significant effect on surface wettability. The best wettability was obtained from the anodized sample. In the samples whose corrosion and tribocorrosion performances were examined, it was observed that the highest resistance was obtained from the anodized sample, compared to other samples. Graphical abstract: [Figure not available: see fulltext.]. © 2023, The Author(s), under exclusive licence to The Materials Research Society. | |
| dc.description.sponsorship | UK Research and Innovation, UKRI, (103683) | |
| dc.identifier.doi | 10.1557/s43579-023-00387-6 | |
| dc.identifier.eissn | 2159-6867 | |
| dc.identifier.endpage | 593 | |
| dc.identifier.issn | 2159-6859 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85163183244 | |
| dc.identifier.startpage | 587 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/12388 | |
| dc.identifier.volume | 13 | |
| dc.identifier.wos | WOS:001019308100001 | |
| dc.language.iso | en | |
| dc.publisher | Springer Nature | |
| dc.relation.ispartof | MRS Communications | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Biomaterial | |
| dc.subject | Coating | |
| dc.subject | Corrosion | |
| dc.subject | Oxidation | |
| dc.subject | Ti | |
| dc.subject | Tribology | |
| dc.subject | Corrosion resistant coatings | |
| dc.subject | Medical applications | |
| dc.subject | Morphology | |
| dc.subject | Surface morphology | |
| dc.subject | Titanium | |
| dc.subject | Titanium compounds | |
| dc.subject | Wetting | |
| dc.subject | Anodized samples | |
| dc.subject | Applied surface | |
| dc.subject | Biomedical applications | |
| dc.subject | Commercially pure titanium | |
| dc.subject | Corrosion behaviour | |
| dc.subject | Performance | |
| dc.subject | Surface wettability | |
| dc.subject | Tribo-corrosion | |
| dc.subject | Tribocorrosion behavior | |
| dc.title | Investigation of surface wettability, corrosion and tribocorrosion behavior of machined, etched, blasted and anodized Cp-Ti samples | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 1 | |
| rdl.citation.wos | 1 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |