Investigation of surface wettability, corrosion and tribocorrosion behavior of machined, etched, blasted and anodized Cp-Ti samples

ArticleAçık Erişim

Özet

Machined, etched, blasted, and anodized commercially pure titanium (Cp-Ti) samples were used in this study. The aim of this study is to examine the effects of the most applied surface treatments on Cp-Ti samples, which are preferred for use in biomedical applications, on surface wettability, corrosion, and tribocorrosion behaviors. It was observed that surface morphology had a significant effect on surface wettability. The best wettability was obtained from the anodized sample. In the samples whose corrosion and tribocorrosion performances were examined, it was observed that the highest resistance was obtained from the anodized sample, compared to other samples. Graphical abstract: [Figure not available: see fulltext.]. © 2023, The Author(s), under exclusive licence to The Materials Research Society.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12388Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1557/s43579-023-00387-6Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAcar, M.T.
dc.date.accessioned2026-10-18T20:27:17.836533206Z
dc.date.available2026-10-18T20:27:17.836533206Z
dc.date.issued2023
dc.description.abstractMachined, etched, blasted, and anodized commercially pure titanium (Cp-Ti) samples were used in this study. The aim of this study is to examine the effects of the most applied surface treatments on Cp-Ti samples, which are preferred for use in biomedical applications, on surface wettability, corrosion, and tribocorrosion behaviors. It was observed that surface morphology had a significant effect on surface wettability. The best wettability was obtained from the anodized sample. In the samples whose corrosion and tribocorrosion performances were examined, it was observed that the highest resistance was obtained from the anodized sample, compared to other samples. Graphical abstract: [Figure not available: see fulltext.]. © 2023, The Author(s), under exclusive licence to The Materials Research Society.
dc.description.sponsorshipUK Research and Innovation, UKRI, (103683)
dc.identifier.doi10.1557/s43579-023-00387-6
dc.identifier.eissn2159-6867
dc.identifier.endpage593
dc.identifier.issn2159-6859
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85163183244
dc.identifier.startpage587
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12388
dc.identifier.volume13
dc.identifier.wosWOS:001019308100001
dc.language.isoen
dc.publisherSpringer Nature
dc.relation.ispartofMRS Communications
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBiomaterial
dc.subjectCoating
dc.subjectCorrosion
dc.subjectOxidation
dc.subjectTi
dc.subjectTribology
dc.subjectCorrosion resistant coatings
dc.subjectMedical applications
dc.subjectMorphology
dc.subjectSurface morphology
dc.subjectTitanium
dc.subjectTitanium compounds
dc.subjectWetting
dc.subjectAnodized samples
dc.subjectApplied surface
dc.subjectBiomedical applications
dc.subjectCommercially pure titanium
dc.subjectCorrosion behaviour
dc.subjectPerformance
dc.subjectSurface wettability
dc.subjectTribo-corrosion
dc.subjectTribocorrosion behavior
dc.titleInvestigation of surface wettability, corrosion and tribocorrosion behavior of machined, etched, blasted and anodized Cp-Ti samples
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus1
rdl.citation.wos1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)