An experimental study on seismic performance levels of highly corroded reinforced concrete columns

ArticleAçık Erişim

Özet

In the literature, only one empirical model is available as a nondestructive method for the prediction of seismic performance levels of corroded reinforced concrete (RC) columns as a function of the initial corrosion crack width at lower corrosion levels. Because of the ruptured transverse reinforcement bars at higher corrosion levels, the structural behavior may turn brittle in terms of shear failure. Therefore, in this study, higher corrosion levels for a different concrete strength level from that empirical model were studied. To do this, four RC columns were subjected to accelerated corrosion, and the widths of initial corrosion cracks were measured. The corroded RC columns were then tested under combined constant axial load and cyclic lateral displacement excursions. After the cyclic loading test, the actual corrosion levels at each reinforcement bar were obtained by extracting the reinforcement bars from the concrete. Test results showed that the prediction of seismic performance levels of corroded RC columns based on initial corrosion crack widths were limited owing to the nonlinear increase in the crack width with the increase in the corrosion levels. New empirical models were developed to predict the remaining energy capacities and seismic performance levels of the corroded RC columns. © 2021 International Federation for Structural Concrete.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12628Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/suco.202100065Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCelik, Alper
dc.contributor.authorYalciner, Hakan
dc.contributor.authorKumbasaroglu, Atila
dc.contributor.authorTuran, Ahmet İhsan
dc.date.accessioned2026-10-18T20:27:30.560174639Z
dc.date.available2026-10-18T20:27:30.560174639Z
dc.date.issued2022
dc.description.abstractIn the literature, only one empirical model is available as a nondestructive method for the prediction of seismic performance levels of corroded reinforced concrete (RC) columns as a function of the initial corrosion crack width at lower corrosion levels. Because of the ruptured transverse reinforcement bars at higher corrosion levels, the structural behavior may turn brittle in terms of shear failure. Therefore, in this study, higher corrosion levels for a different concrete strength level from that empirical model were studied. To do this, four RC columns were subjected to accelerated corrosion, and the widths of initial corrosion cracks were measured. The corroded RC columns were then tested under combined constant axial load and cyclic lateral displacement excursions. After the cyclic loading test, the actual corrosion levels at each reinforcement bar were obtained by extracting the reinforcement bars from the concrete. Test results showed that the prediction of seismic performance levels of corroded RC columns based on initial corrosion crack widths were limited owing to the nonlinear increase in the crack width with the increase in the corrosion levels. New empirical models were developed to predict the remaining energy capacities and seismic performance levels of the corroded RC columns. © 2021 International Federation for Structural Concrete.
dc.description.sponsorshipFunding text 1: This study was funded by the Scientific Research Commission of Erzincan Binali Yıldırım University under grant number BAP‐FBA‐2020‐659. ; Funding text 2: This study was funded by the Scientific Research Commission of Erzincan Binali Y?ld?r?m University under grant number BAP-FBA-2020-659.
dc.identifier.doi10.1002/suco.202100065
dc.identifier.eissn1751-7648
dc.identifier.endpage50
dc.identifier.issn1464-4177
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85109338068
dc.identifier.startpage32
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12628
dc.identifier.volume23
dc.identifier.wosWOS:000669987400001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofStructural Concrete
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcorrosion
dc.subjectcrack width
dc.subjectcyclic loading
dc.subjectreinforced concrete column
dc.subjectreinforcement bar
dc.subjectseismic performance level
dc.subjectConcrete construction
dc.subjectCyclic loads
dc.subjectDielectric properties
dc.subjectForecasting
dc.subjectRebar
dc.subjectSeismic waves
dc.subjectSeismology
dc.subjectAccelerated corrosion
dc.subjectCyclic loading test
dc.subjectLateral displacements
dc.subjectNondestructive methods
dc.subjectSeismic Performance
dc.subjectStructural behaviors
dc.subjectTransverse reinforcement
dc.subjectReinforced concrete
dc.titleAn experimental study on seismic performance levels of highly corroded reinforced concrete columns
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus48
rdl.citation.wos42
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)