Finite element analysis of stress distribution in autotransplanted molars

ArticleAçık Erişim

Özet

Objective: The biomechanical response of an autotransplanted tooth and surrounding bone to occlusal loads is not well-known. The aim of the present study was to investigate the effect of root form and occlusal morphology on stress distribution in autotransplanted teeth and surrounding bone by using finite element analysis (FEA). Methods: Seven FEA models representing different autotransplanted tooth situations were generated: (a) first molar, (b) third molar, (c) root canal-treated third molar, (d) root canal-treated, ankylosed, third molar, (e) crowned third molar, (f) crowned and root canal-treated third molar, (g) root canal-treated, ankylosed, and crowned third molar. Load (200 N) was applied on the occlusal surface, parallel to the long axis of the tooth. Maximum von Mises stress values on dentin and surrounding bone were calculated for each situation. Results: Differences in stress distribution were observed among models. In ankylosed model, stress was primarily observed at the coronal region of the tooth. The stress was observed more at the coronal region of the tooth in crowned models compared with the non-crowned models. The stress distribution was homogeneous with root canal-treated and crowned autotransplanted tooth. Conclusions: The occlusal morphology and root form of the autotransplanted tooth affected the stress in surrounding bone at the transfer site and the biomechanical response of the tooth. The stress was more homogeneous in crowned tooth and primarily observed at the coronal region, which may decrease the risk for root resorption. Clinical significance: Root configuration, occlusal form and root canal treatment induce significant changes on the stress distribution on teeth and bone, including characteristic stress concentration and increased stress values. Clinicians can consider crowning autotransplanted teeth for improved stress distribution within the tooth structure. © 2022

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12640Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.jdent.2022.104082Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKırmalı, Ömer
dc.contributor.authorTürker, Nurullah
dc.contributor.authorAkar, Türker
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2026-10-18T20:27:31.153977342Z
dc.date.available2026-10-18T20:27:31.153977342Z
dc.date.issued2022
dc.description.abstractObjective: The biomechanical response of an autotransplanted tooth and surrounding bone to occlusal loads is not well-known. The aim of the present study was to investigate the effect of root form and occlusal morphology on stress distribution in autotransplanted teeth and surrounding bone by using finite element analysis (FEA). Methods: Seven FEA models representing different autotransplanted tooth situations were generated: (a) first molar, (b) third molar, (c) root canal-treated third molar, (d) root canal-treated, ankylosed, third molar, (e) crowned third molar, (f) crowned and root canal-treated third molar, (g) root canal-treated, ankylosed, and crowned third molar. Load (200 N) was applied on the occlusal surface, parallel to the long axis of the tooth. Maximum von Mises stress values on dentin and surrounding bone were calculated for each situation. Results: Differences in stress distribution were observed among models. In ankylosed model, stress was primarily observed at the coronal region of the tooth. The stress was observed more at the coronal region of the tooth in crowned models compared with the non-crowned models. The stress distribution was homogeneous with root canal-treated and crowned autotransplanted tooth. Conclusions: The occlusal morphology and root form of the autotransplanted tooth affected the stress in surrounding bone at the transfer site and the biomechanical response of the tooth. The stress was more homogeneous in crowned tooth and primarily observed at the coronal region, which may decrease the risk for root resorption. Clinical significance: Root configuration, occlusal form and root canal treatment induce significant changes on the stress distribution on teeth and bone, including characteristic stress concentration and increased stress values. Clinicians can consider crowning autotransplanted teeth for improved stress distribution within the tooth structure. © 2022
dc.identifier.doi10.1016/j.jdent.2022.104082
dc.identifier.eissn1879-176X
dc.identifier.issn0300-5712
dc.identifier.pmid35247471
dc.identifier.scopus2-s2.0-85125778959
dc.identifier.startpage104082
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12640
dc.identifier.volume119
dc.identifier.wosWOS:000793705400001
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofJournal of Dentistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAnkylosis
dc.subjectAutotransplantation
dc.subjectBiomimetic
dc.subjectFinite elemental analysis
dc.subjectPeriodontal ligament
dc.subjectFinite Element Analysis
dc.subjectHumans
dc.subjectMolar
dc.subjectMolar, Third
dc.subjectStress, Mechanical
dc.subjectTooth, Nonvital
dc.subjecthuman
dc.subjectmechanical stress
dc.subjectmolar tooth
dc.subjectthird molar
dc.subjecttooth pulp disease
dc.titleFinite element analysis of stress distribution in autotransplanted molars
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus21
rdl.citation.wos17
rdl.departmentDepartment of Prosthodontics, Faculty of Dentistry, Erzincan University, Erzincan, Turkey.
rdl.oa.statusgreen
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)