Functional and radiological comparison of three cephalomedullary nails with different designs used in the treatment of unstable intertrochanteric femur fractures of elderly; [Yaşlılarda instabil intertrokanterik femur kırıklarının tedavisinde kullanılan dizaynları farklı üç sefalomedüller çivinin fonksiyonel ve radyolojik açıdan karşılaştırılması]

ArticleAçık Erişim

Özet

BACKGROUND: The aim of this study to compare three cephalomedullary nails (CMNs) with different designs in terms of complica-tion, reoperation, implant failure, mortality rates, and functional outcomes in the treatment of unstable intertrochanteric fractures (UIFs). METHODS: This retrospective study included patients with UIFs (AO/OTA type 31-A2 and 31-A3) who were treated with one of these CMNs (74 patients with Talon-PFN, 70 patients with PFN-III, and 69 patients with Intertan) between October 2014 and October 2018. RESULTS: A total of 213 patients (122 females and 91 males) with a mean age of 81.0±9.3 years have participated in this study. The mean follow-up time was 26.1±6.3 months. Malfixation was the most common complication and the most common reason of reop-eration for each type of CMN. Complication and reoperation rates, post-operative functional status, mean union times, and overall mortality rates were similar between groups. Mean operation/fluoroscopy time and mean blood loss were low in the Talon-PFN group, whereas the highest means of these parameters were in the PFN-III group. There were six (8.2%) implant failures in the Talon-PFN group and one (1.5%) in PFN-III group. No implant failure was seen in the Intertan group. The highest rate (58.6%) of anatomic reduction was detected in PFN-III group. CONCLUSION: Our study results showed that each implant type had its own advantages and disadvantages in the treatment of UIFs with similar functional and reoperation outcomes. Intertan was advantageous with its absence of implant failures. Talon-PFN decreased the operation/fluoroscopy time and intraoperative blood loss but had the highest implant failure rate. There was a need for more anatomic reduction to centralize two separate parallel lag screws in the femoral neck in PFN-III group, and that costs operation/fluo-roscopy time and blood loss. Malfixation, which was the most common cause of complications and reoperations, should be avoided. © 2022 Turkish Association of Trauma and Emergency Surgery.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12732Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.14744/tjtes.2020.80733Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYapici, Furkan
dc.contributor.authorUcpunar, Hanifi
dc.contributor.authorGur, Volkan
dc.contributor.authorOnac, Osman
dc.contributor.authorAlpay, Yakup
dc.contributor.authorKarakose, Reşit
dc.contributor.authorCamurcu, Yalkin
dc.date.accessioned2026-10-18T20:27:35.929206702Z
dc.date.available2026-10-18T20:27:35.929206702Z
dc.date.issued2022
dc.description.abstractBACKGROUND: The aim of this study to compare three cephalomedullary nails (CMNs) with different designs in terms of complica-tion, reoperation, implant failure, mortality rates, and functional outcomes in the treatment of unstable intertrochanteric fractures (UIFs). METHODS: This retrospective study included patients with UIFs (AO/OTA type 31-A2 and 31-A3) who were treated with one of these CMNs (74 patients with Talon-PFN, 70 patients with PFN-III, and 69 patients with Intertan) between October 2014 and October 2018. RESULTS: A total of 213 patients (122 females and 91 males) with a mean age of 81.0±9.3 years have participated in this study. The mean follow-up time was 26.1±6.3 months. Malfixation was the most common complication and the most common reason of reop-eration for each type of CMN. Complication and reoperation rates, post-operative functional status, mean union times, and overall mortality rates were similar between groups. Mean operation/fluoroscopy time and mean blood loss were low in the Talon-PFN group, whereas the highest means of these parameters were in the PFN-III group. There were six (8.2%) implant failures in the Talon-PFN group and one (1.5%) in PFN-III group. No implant failure was seen in the Intertan group. The highest rate (58.6%) of anatomic reduction was detected in PFN-III group. CONCLUSION: Our study results showed that each implant type had its own advantages and disadvantages in the treatment of UIFs with similar functional and reoperation outcomes. Intertan was advantageous with its absence of implant failures. Talon-PFN decreased the operation/fluoroscopy time and intraoperative blood loss but had the highest implant failure rate. There was a need for more anatomic reduction to centralize two separate parallel lag screws in the femoral neck in PFN-III group, and that costs operation/fluo-roscopy time and blood loss. Malfixation, which was the most common cause of complications and reoperations, should be avoided. © 2022 Turkish Association of Trauma and Emergency Surgery.
dc.identifier.doi10.14744/tjtes.2020.80733
dc.identifier.eissn1307-7945
dc.identifier.endpage677
dc.identifier.issn1306-696X
dc.identifier.issue5
dc.identifier.pmcidPMC10442976
dc.identifier.pmid35485475
dc.identifier.scopus2-s2.0-85129780168
dc.identifier.startpage668
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12732
dc.identifier.volume28
dc.identifier.wosWOS:000795126700015
dc.language.isoen
dc.publisherTurkish Association of Trauma and Emergency Surgery
dc.relation.ispartofUlusal Travma ve Acil Cerrahi Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCephalomedullary nail
dc.subjectelderly
dc.subjectfracture healing
dc.subjecthip fracture
dc.subjectintertrochanteric fracture
dc.subjectintramedullary nailing
dc.subjectpost-operative complications
dc.subjecttreatment outcome
dc.subjectAged
dc.subjectAged, 80 and over
dc.subjectBone Nails
dc.subjectFemale
dc.subjectFemur
dc.subjectHip Fractures
dc.subjectHumans
dc.subjectMale
dc.subjectNails
dc.subjectRadiography
dc.subjectRetrospective Studies
dc.subjectArticle
dc.subjectavascular necrosis
dc.subjectbending breakage of implant
dc.subjectclinical outcome
dc.subjectcomparative study
dc.subjectcontrolled study
dc.subjectdeep infection
dc.subjectfail of integral locking mechanism
dc.subjectfailed talon deployment of the lag screw
dc.subjectfemur intertrochanteric fracture
dc.subjectfollow up
dc.titleFunctional and radiological comparison of three cephalomedullary nails with different designs used in the treatment of unstable intertrochanteric femur fractures of elderly; [Yaşlılarda instabil intertrokanterik femur kırıklarının tedavisinde kullanılan dizaynları farklı üç sefalomedüller çivinin fonksiyonel ve radyolojik açıdan karşılaştırılması]
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.trdizin1
rdl.citation.wos3
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentT.C. SAĞLIK BAKANLIĞI
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.source.indexPUBMED