Analysis of eye movements with 2d images obtained by eog signals

Conference ObjectAçık Erişim

Özet

EOG signals are used for diagnosing of various eye diseases and dysfunctions and eye movement monitoring in neurological disorders. It has also been used as a source signal for various electronic systems and human-machine interfaces, especially in recent years, since the movements of the eye in the horizontal and vertical axis and blinking movements can be detected by EOG. In using EOG signals as source signals, it is necessary to analyze this signal and use various features extracted from the signal. In this study, EOG signals from one of the authors were used with the Biopac MP30 device within the scope of the Sakarya University Electrical and Electronics Engineering, Biomedical Laboratory course. EOG signs were used in four classes looking up, down, right and left. Scalogram matrices are extracted for each movement in the EOG signals with the continuous wavelet transform. As a result of the imaging of the scalogram matrices, it was seen that there were significant differences in the images of the four classes. It is predicted that the results of the analysis made on the images can improve the accuracy rates in classification systems according to one-dimensional analysis methods when used together with expert systems. © 2022 Published by ISRES Publishing.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12861Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.55549/epstem.1224982Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaragoz-Sahin, Yurdagul
dc.contributor.authorBozkurt, Mehmet Recep
dc.contributor.authorKilic, Elcin
dc.contributor.editorM., Ozaslan
dc.date.accessioned2026-10-18T20:27:43.394690270Z
dc.date.available2026-10-18T20:27:43.394690270Z
dc.date.issued2022
dc.description.abstractEOG signals are used for diagnosing of various eye diseases and dysfunctions and eye movement monitoring in neurological disorders. It has also been used as a source signal for various electronic systems and human-machine interfaces, especially in recent years, since the movements of the eye in the horizontal and vertical axis and blinking movements can be detected by EOG. In using EOG signals as source signals, it is necessary to analyze this signal and use various features extracted from the signal. In this study, EOG signals from one of the authors were used with the Biopac MP30 device within the scope of the Sakarya University Electrical and Electronics Engineering, Biomedical Laboratory course. EOG signs were used in four classes looking up, down, right and left. Scalogram matrices are extracted for each movement in the EOG signals with the continuous wavelet transform. As a result of the imaging of the scalogram matrices, it was seen that there were significant differences in the images of the four classes. It is predicted that the results of the analysis made on the images can improve the accuracy rates in classification systems according to one-dimensional analysis methods when used together with expert systems. © 2022 Published by ISRES Publishing.
dc.identifier.doi10.55549/epstem.1224982
dc.identifier.endpage115
dc.identifier.isbn978-605728324-5
dc.identifier.issn2602-3199
dc.identifier.scopus2-s2.0-85146583555
dc.identifier.startpage110
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12861
dc.identifier.volume21
dc.language.isoen
dc.publisherISRES Publishing
dc.relation.ispartofEurasia Proceedings of Science, Technology, Engineering and Mathematics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectElectro-oculography
dc.subjectMedical signal processing
dc.subjectScalogram computation
dc.subjectSignal classification
dc.titleAnalysis of eye movements with 2d images obtained by eog signals
dc.typeConference Object
dspace.entity.typePublication
rdl.citation.scopus0
rdl.oa.statusgold
rdl.source.indexSCOPUS