For intramedullary nailing of femoral shaft fractures, talon fixation is helpful to cope with the troublesome distal locking, but conventional distal locking with screws offers a more stable construct: Talon femoral nail versus conventional femoral nail; [Femur şaft kırıklarının intramedüller çivilenmesinde, talon fiksasyonu zahmetli distal kilitlemeyle başa çıkmada yararlıdır, ancak vidalarla konvansiyonel distal kilitleme daha stabil bir yapı sunar: Talon femoral çiviye karşı konvansiyonel femoral çivi]

ArticleAçık Erişim

Özet

BACKGROUND: A novel-design femoral nail (FN) with distal talon deployment (Talon-FN) has emerged in the market to cope with problematic distal locking. We aimed to compare the radiological and functional outcomes of the Talon-FN with a conventional FN (Con-FN) for the treatment of femoral shaft fracture (FSFs). METHODS: This retrospective study included 85 patients (57 men, 28 women; mean age: 46.8±23.9 years) with FSFs (AO types 32-A and B) who were treated with FNs (Talon-FN: 41, Con-FN: 44) during October 2014–2018. Knee injury and Osteoarthritis Outcome Score Physical Function Shortform, Hip injury and Osteoarthritis Outcome Score Physical Function Shortform, Short musculoskeletal function assessment bother and dysfunction indexes were used for functional assessment. RESULTS: The mean follow-up time was 25.8±6.7 months. The complication rates were 19.6% and 20.5% for Talon-FN and Con-FN, respectively (p=0.92). Malunion was the most common complication for each FN type (Talon-FN: 9.8%, Con-FN: 9.1%). All of the Talon-FN group’s malunions were axial (shortening and malrotation) and happened gradually. In contrast, the Con-FN group’s malu-nions were angular (varus and valgus) and caused by initial malreduction. The Talon-FN group’s two patients with shortening (4.9%) had AO 32-B type fractures, and the other two with malrotation (4.9%) had AO 32-A3 type fractures, all of four fractures were localized distal to the femoral isthmus. The post-operative functional outcomes were similar between the groups (all p>0.05). The mean op-eration/fluoroscopy time and the mean blood loss were lower in the Talon-FN group, while the mean union time was shorter in the Con-FN group (all p<0.01). No nonunion was noted in either group. The reoperation rates were similar at approximately 5% (p=0.95). CONCLUSION: Our study results revealed that the Talon-FN shortens the operation/fluoroscopy time and decreases the intra-operative blood loss with similar functional outcomes. However, the Con-FN seems to offer a more stable construct against axial malunion with a shorter bone union time. The Talon-FN should not be used in FSFs distal to the femoral isthmus with certain types of fractures prone to shortening and malrotation. © 2022, Turkish Association of Trauma and Emergency Surgery. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12970Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.14744/tjtes.2021.55867Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYapici, Furkan
dc.contributor.authorGur, Volkan
dc.contributor.authorOnac, Osman
dc.contributor.authorAlpay, Yakup
dc.contributor.authorTardus, Ismail
dc.contributor.authorUcpunar, Hanifi
dc.contributor.authorCamurcu, Yalkin
dc.date.accessioned2026-10-18T20:27:49.640786871Z
dc.date.available2026-10-18T20:27:49.640786871Z
dc.date.issued2022
dc.description.abstractBACKGROUND: A novel-design femoral nail (FN) with distal talon deployment (Talon-FN) has emerged in the market to cope with problematic distal locking. We aimed to compare the radiological and functional outcomes of the Talon-FN with a conventional FN (Con-FN) for the treatment of femoral shaft fracture (FSFs). METHODS: This retrospective study included 85 patients (57 men, 28 women; mean age: 46.8±23.9 years) with FSFs (AO types 32-A and B) who were treated with FNs (Talon-FN: 41, Con-FN: 44) during October 2014–2018. Knee injury and Osteoarthritis Outcome Score Physical Function Shortform, Hip injury and Osteoarthritis Outcome Score Physical Function Shortform, Short musculoskeletal function assessment bother and dysfunction indexes were used for functional assessment. RESULTS: The mean follow-up time was 25.8±6.7 months. The complication rates were 19.6% and 20.5% for Talon-FN and Con-FN, respectively (p=0.92). Malunion was the most common complication for each FN type (Talon-FN: 9.8%, Con-FN: 9.1%). All of the Talon-FN group’s malunions were axial (shortening and malrotation) and happened gradually. In contrast, the Con-FN group’s malu-nions were angular (varus and valgus) and caused by initial malreduction. The Talon-FN group’s two patients with shortening (4.9%) had AO 32-B type fractures, and the other two with malrotation (4.9%) had AO 32-A3 type fractures, all of four fractures were localized distal to the femoral isthmus. The post-operative functional outcomes were similar between the groups (all p>0.05). The mean op-eration/fluoroscopy time and the mean blood loss were lower in the Talon-FN group, while the mean union time was shorter in the Con-FN group (all p<0.01). No nonunion was noted in either group. The reoperation rates were similar at approximately 5% (p=0.95). CONCLUSION: Our study results revealed that the Talon-FN shortens the operation/fluoroscopy time and decreases the intra-operative blood loss with similar functional outcomes. However, the Con-FN seems to offer a more stable construct against axial malunion with a shorter bone union time. The Talon-FN should not be used in FSFs distal to the femoral isthmus with certain types of fractures prone to shortening and malrotation. © 2022, Turkish Association of Trauma and Emergency Surgery. All rights reserved.
dc.identifier.doi10.14744/tjtes.2021.55867
dc.identifier.eissn1307-7945
dc.identifier.endpage522
dc.identifier.issn1306-696X
dc.identifier.issue4
dc.identifier.pmcidPMC10521001
dc.identifier.pmid35485511
dc.identifier.scopus2-s2.0-85128472262
dc.identifier.startpage513
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12970
dc.identifier.volume28
dc.identifier.wosWOS:000781192000016
dc.language.isoen
dc.publisherTurkish Association of Trauma and Emergency Surgery
dc.relation.ispartofUlusal Travma ve Acil Cerrahi Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComplication
dc.subjectconventional femoral nail
dc.subjectdistal locking, stabilite
dc.subjectfemoral shaft fracture
dc.subjectfunctional outcome
dc.subjectmalunion
dc.subjectradiological outcome
dc.subjecttalon femoral nail
dc.subjectAdult
dc.subjectAged
dc.subjectFemale
dc.subjectFemoral Fractures
dc.subjectFemur
dc.subjectFracture Fixation, Intramedullary
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectOsteoarthritis
dc.subjectRetrospective Studies
dc.subjectYoung Adult
dc.subjectArticle
dc.subjectbleeding
dc.subjectbroken interlocking screw
dc.subjectdeep infection
dc.subjectdeep vein thrombosis
dc.subjectfemur shaft fracture
dc.subjectfluoroscopy
dc.subjectfollow up
dc.subjectfracture fixation
dc.subjectfracture nonunion
dc.titleFor intramedullary nailing of femoral shaft fractures, talon fixation is helpful to cope with the troublesome distal locking, but conventional distal locking with screws offers a more stable construct: Talon femoral nail versus conventional femoral nail; [Femur şaft kırıklarının intramedüller çivilenmesinde, talon fiksasyonu zahmetli distal kilitlemeyle başa çıkmada yararlıdır, ancak vidalarla konvansiyonel distal kilitleme daha stabil bir yapı sunar: Talon femoral çiviye karşı konvansiyonel femoral çivi]
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.trdizin3
rdl.citation.wos4
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentİSTANBUL ATLAS ÜNİVERSİTESİ
rdl.departmentT.C. SAĞLIK BAKANLIĞI
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)