Electrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode

ArticleAçık Erişim

Özet

In this paper, an electrochemical sensor for levofloxacin detection was developed by electrochemical polymerization of pyrogallol red (PGR) on the glassy carbon electrode (GCE) surfaces. Surface morphology and electrical properties of the Poly(PGR)/GCE obtained was characterized by SEM and EIS techniques. Voltammetric behaviour of the levofloxacin was found pH dependent, and the best response was obtained at pH 6.0 PBS. By monitoring the peak current at around 0.9 V, a wide linear range of calibration graph: from 0.2 μM- 15 μM LEV and 15 μM- 355 μM for levofloxacin, and very low detection limit of 97 nM were achieved with amperometry. Selectivity of the method developed was proven in the presence of possible interfering substances and the method was successfully employed for levofloxacin detection in pharmaceutical tablet and synthetic urine sample. © 2022 Wiley-VCH GmbH.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12975Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/slct.202201864Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKoçak, Çağrı Ceylan
dc.contributor.authorAslışen, Burak
dc.contributor.authorKarabiberoğlu, Şükriye
dc.contributor.authorÖzdokur, Kemal Volkan
dc.contributor.authorAslan, Avni
dc.contributor.authorKoçak, Süleyman
dc.date.accessioned2026-10-18T20:27:49.869056893Z
dc.date.available2026-10-18T20:27:49.869056893Z
dc.date.issued2022
dc.description.abstractIn this paper, an electrochemical sensor for levofloxacin detection was developed by electrochemical polymerization of pyrogallol red (PGR) on the glassy carbon electrode (GCE) surfaces. Surface morphology and electrical properties of the Poly(PGR)/GCE obtained was characterized by SEM and EIS techniques. Voltammetric behaviour of the levofloxacin was found pH dependent, and the best response was obtained at pH 6.0 PBS. By monitoring the peak current at around 0.9 V, a wide linear range of calibration graph: from 0.2 μM- 15 μM LEV and 15 μM- 355 μM for levofloxacin, and very low detection limit of 97 nM were achieved with amperometry. Selectivity of the method developed was proven in the presence of possible interfering substances and the method was successfully employed for levofloxacin detection in pharmaceutical tablet and synthetic urine sample. © 2022 Wiley-VCH GmbH.
dc.description.sponsorshipAuthors would like to thank to Manisa Celal Bayar University Applied Science and Research Center (DEFAM).
dc.identifier.doi10.1002/slct.202201864
dc.identifier.issn2365-6549
dc.identifier.issue41
dc.identifier.scopus2-s2.0-85141743401
dc.identifier.startpagee202201864
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12975
dc.identifier.volume7
dc.identifier.wosWOS:000878354200001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofChemistrySelect
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAmperometry
dc.subjectLevofloxacin
dc.subjectPharmaceutic
dc.subjectPoly(Pyrogallol Red)
dc.subjectVoltammetry
dc.titleElectrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus33
rdl.citation.wos26
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)