Solid-state Electrochemical Sensor Based on a Cross-linked Copper(II)-doped Copolymer and Carbon Nanotube Material for Selective and Sensitive Detection of Monohydrogen Phosphate
ArticleAçık Erişim
Özet
A novel solid-state electrochemical sensor based on a newly synthesized cross-linked copper(II) doped-copolymer and carbon nanotube material was developed for the direct determination of monohydrogen phosphate ions (HPO42−). The synthesized copolymers were characterized by FTIR, XPS, TG/DTG-DTA and SEM techniques. The sensor had a Nernstian slope:-30.7±0.4 mV/decade, linear concentrations range: 1.0×10−6 - 1.0×10−1 M, detection limit: 6.5×10−7 M, response time: 4 s and life time: 17 weeks. The sensor displayed constant potentials in the pH range 7.0-9.5. The sensor was successfully used as an indicator electrode in potentiometric titration and the direct determination of HPO42− in water samples. © 2021 Wiley-VCH GmbH.
Anahtar Kelimeler
Carbon nanotubeCopper(II) doped-copolymerMonohydrogen phosphate sensorPotentiometric monohydrogen phosphate determinationSolid-state sensorWater analysisCopper compoundsElectrochemical sensorsPotentiometers (electric measuring instruments)Potentiometric sensorsTitrationVoltammetryCarbon nanotubes materialsDirect determinationFTIRPotentiometricsSelective detectionSensitive detectionSynthesisedCarbon nanotubes
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12990Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Topcu, Cihan | |
| dc.contributor.author | Coldur, Fatih | |
| dc.contributor.author | Caglar, Bulent | |
| dc.contributor.author | Ozdokur, K. Volkan | |
| dc.contributor.author | Cubuk, Osman | |
| dc.date.accessioned | 2026-10-18T20:27:50.507692307Z | |
| dc.date.available | 2026-10-18T20:27:50.507692307Z | |
| dc.date.issued | 2022 | |
| dc.description.abstract | A novel solid-state electrochemical sensor based on a newly synthesized cross-linked copper(II) doped-copolymer and carbon nanotube material was developed for the direct determination of monohydrogen phosphate ions (HPO42−). The synthesized copolymers were characterized by FTIR, XPS, TG/DTG-DTA and SEM techniques. The sensor had a Nernstian slope:-30.7±0.4 mV/decade, linear concentrations range: 1.0×10−6 - 1.0×10−1 M, detection limit: 6.5×10−7 M, response time: 4 s and life time: 17 weeks. The sensor displayed constant potentials in the pH range 7.0-9.5. The sensor was successfully used as an indicator electrode in potentiometric titration and the direct determination of HPO42− in water samples. © 2021 Wiley-VCH GmbH. | |
| dc.identifier.doi | 10.1002/elan.202100340 | |
| dc.identifier.eissn | 1521-4109 | |
| dc.identifier.endpage | 484 | |
| dc.identifier.issn | 1040-0397 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-85119044009 | |
| dc.identifier.startpage | 474 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/12990 | |
| dc.identifier.volume | 34 | |
| dc.identifier.wos | WOS:000719404800001 | |
| dc.language.iso | en | |
| dc.publisher | John Wiley and Sons Inc | |
| dc.relation.ispartof | Electroanalysis | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Carbon nanotube | |
| dc.subject | Copper(II) doped-copolymer | |
| dc.subject | Monohydrogen phosphate sensor | |
| dc.subject | Potentiometric monohydrogen phosphate determination | |
| dc.subject | Solid-state sensor | |
| dc.subject | Water analysis | |
| dc.subject | Copper compounds | |
| dc.subject | Electrochemical sensors | |
| dc.subject | Potentiometers (electric measuring instruments) | |
| dc.subject | Potentiometric sensors | |
| dc.subject | Titration | |
| dc.subject | Voltammetry | |
| dc.subject | Carbon nanotubes materials | |
| dc.subject | Direct determination | |
| dc.subject | FTIR | |
| dc.subject | Potentiometrics | |
| dc.subject | Selective detection | |
| dc.subject | Sensitive detection | |
| dc.subject | Synthesised | |
| dc.subject | Carbon nanotubes | |
| dc.title | Solid-state Electrochemical Sensor Based on a Cross-linked Copper(II)-doped Copolymer and Carbon Nanotube Material for Selective and Sensitive Detection of Monohydrogen Phosphate | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 5 | |
| rdl.citation.wos | 5 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
