Comparison of postoperative morbidity between piezoelectric surgery and conventional rotary instruments in mandibular third molar surgery: A split-mouth clinical study

ArticleAçık Erişim

Özet

Background: The extraction of impacted third molar teeth is a common procedure in maxillofacial surgery. The aim of this study was to compare of piezoelectric surgical technique with the one with conventional rotary instruments in terms of edema, trismus and pain, in mandibular third molar surgery. Material and Methods: 20 individuals with symmetrically impacted lower mandibular third molars and 40 teeth were included in the study. Third molars on the left side of each patient were removed with piezosurgery, while the counterparts on the right side were removed with conventional rotary instruments. Postoperatively, the same antibiotic, analgesic, and mouthwash were recommended to both groups. Ultrasound, edema, trismus measurements were performed before surgery, postoperative, postoperative day 2 and postoperative day 7. VAS scale was used to evaluate the pain. Results: The average age of 20 individuals included in the study was found to be 21.85 ± 3.08 years. The operation time of the individuals who underwent the surgery with conventional rotary instruments was found to be 12 minutes 31.70 ± 167.03 seconds, and the operation time in the Piezosurgery group was 19 minutes 10.60 ± 306.59 seconds. There was no significant difference between the two groups in terms of trismus, edema, and pain. Conclusions: Piezosurgery is a safe method that can be used in molar removal, but in this split-mouth study, it is not found advantageous in terms of postoperative morbidity due to the longer working time compared to the one performed with conventional rotary instruments. © 2021, Medicina Oral S.L.. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13381Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.4317/medoral.24085Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorGulnahar, Yakup
dc.contributor.authorAlpan, Aysan Lektemur
dc.date.accessioned2026-10-18T20:28:13.327930105Z
dc.date.available2026-10-18T20:28:13.327930105Z
dc.date.issued2021
dc.description.abstractBackground: The extraction of impacted third molar teeth is a common procedure in maxillofacial surgery. The aim of this study was to compare of piezoelectric surgical technique with the one with conventional rotary instruments in terms of edema, trismus and pain, in mandibular third molar surgery. Material and Methods: 20 individuals with symmetrically impacted lower mandibular third molars and 40 teeth were included in the study. Third molars on the left side of each patient were removed with piezosurgery, while the counterparts on the right side were removed with conventional rotary instruments. Postoperatively, the same antibiotic, analgesic, and mouthwash were recommended to both groups. Ultrasound, edema, trismus measurements were performed before surgery, postoperative, postoperative day 2 and postoperative day 7. VAS scale was used to evaluate the pain. Results: The average age of 20 individuals included in the study was found to be 21.85 ± 3.08 years. The operation time of the individuals who underwent the surgery with conventional rotary instruments was found to be 12 minutes 31.70 ± 167.03 seconds, and the operation time in the Piezosurgery group was 19 minutes 10.60 ± 306.59 seconds. There was no significant difference between the two groups in terms of trismus, edema, and pain. Conclusions: Piezosurgery is a safe method that can be used in molar removal, but in this split-mouth study, it is not found advantageous in terms of postoperative morbidity due to the longer working time compared to the one performed with conventional rotary instruments. © 2021, Medicina Oral S.L.. All rights reserved.
dc.identifier.doi10.4317/medoral.24085
dc.identifier.endpagee275
dc.identifier.issn1698-4447
dc.identifier.issue3
dc.identifier.pmid33772570
dc.identifier.scopus2-s2.0-85105500928
dc.identifier.startpagee269
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13381
dc.identifier.volume26
dc.identifier.wosWOS:000647697300001
dc.language.isoen
dc.publisherMedicina Oral S.L.
dc.relation.ispartofMedicina Oral Patologia Oral y Cirugia Bucal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEdema
dc.subjectImpacted third molar
dc.subjectPain
dc.subjectPiezosurgery
dc.subjectTrismus
dc.subjectAdult
dc.subjectHumans
dc.subjectMandible
dc.subjectMolar
dc.subjectMolar, Third
dc.subjectMorbidity
dc.subjectMouth
dc.subjectPain, Postoperative
dc.subjectTooth Extraction
dc.subjectTooth, Impacted
dc.subjectYoung Adult
dc.subjectanalgesic agent
dc.subjectantibiotic agent
dc.subjectarticaine
dc.subjectchlorhexidine
dc.subjectclindamycin
dc.subjectepinephrine
dc.subjectketamine
dc.subjectmouthwash
dc.subjectparacetamol
dc.subjectpovidone iodine
dc.subjectalveolar bone
dc.subjectArticle
dc.subjectbacterium colony
dc.subjectclinical article
dc.titleComparison of postoperative morbidity between piezoelectric surgery and conventional rotary instruments in mandibular third molar surgery: A split-mouth clinical study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus16
rdl.citation.wos10
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)