The very forward CASTOR calorimeter of the CMS experiment

ArticleAçık Erişim

Özet

The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1cm from the beam pipe, and at 14.4m from the CMS interaction point, covering the pseudorapidity range of -6.6 < η < -5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC. © 2021 CERN for the benefit of the CMS collaboration..

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13439Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKhachatryan, V.
dc.contributor.authorSirunyan, A.M.
dc.contributor.authorTumasyan, A.
dc.contributor.authorAdam, W.
dc.contributor.authorAmbrogi, F.
dc.contributor.authorBergauer, T.
dc.contributor.authorDragicevic, M.
dc.contributor.authorErö, J.
dc.contributor.authorEscalante Del Valle, A.
dc.contributor.authorFrühwirth, R.
dc.contributor.authorJeitler, M.
dc.contributor.authorKrammer, N.
dc.contributor.authorLechner, L.
dc.contributor.authorLiko, D.
dc.contributor.authorMadlener, T.
dc.contributor.authorMikulec, I.
dc.contributor.authorPitters, F.M.
dc.contributor.authorRad, N.
dc.contributor.authorSchieck, J.
dc.contributor.authorSchöfbeck, R.
dc.contributor.authorSpanring, M.
dc.contributor.authorTempl, S.
dc.contributor.authorWaltenberger, W.
dc.contributor.authorWulz, C.-E.
dc.contributor.authorZarucki, M.
dc.contributor.authorChekhovsky, V.
dc.contributor.authorLitomin, A.
dc.contributor.authorMakarenko, V.
dc.contributor.authorSuarez Gonzalez, J.
dc.contributor.authorBeaumont, W.
dc.contributor.authorDarwish, M.R.
dc.contributor.authorDe Wolf, E.A.
dc.contributor.authorDi Croce, D.
dc.contributor.authorJanssen, X.
dc.contributor.authorKello, T.
dc.contributor.authorLelek, A.
dc.contributor.authorPieters, M.
dc.contributor.authorRejeb Sfar, H.
dc.contributor.authorVan Haevermaet, H.
dc.contributor.authorVan Mechelen, P.
dc.contributor.authorVan Putte, S.
dc.contributor.authorVan Remortel, N.
dc.contributor.authorBlekman, F.
dc.contributor.authorBols, E.S.
dc.contributor.authorChhibra, S.S.
dc.contributor.authorD'Hondt, J.
dc.contributor.authorDe Clercq, J.
dc.contributor.authorLontkovskyi, D.
dc.contributor.authorLowette, S.
dc.contributor.authorMarchesini, I.
dc.date.accessioned2026-10-18T20:28:16.157227604Z
dc.date.available2026-10-18T20:28:16.157227604Z
dc.date.issued2021
dc.description.abstractThe physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1cm from the beam pipe, and at 14.4m from the CMS interaction point, covering the pseudorapidity range of -6.6 < η < -5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC. © 2021 CERN for the benefit of the CMS collaboration..
dc.description.sponsorshipHorizon 2020 Framework Programme, H2020, (675440, 724704, 752730, 765710); Horizon 2020 Framework Programme, H2020
dc.identifier.doi10.1088/1748-0221/16/02/p02010
dc.identifier.issn1748-0221
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85101722929
dc.identifier.startpageP02010
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13439
dc.identifier.volume16
dc.language.isoen
dc.publisherInstitute of Physics
dc.relation.ispartofJournal of Instrumentation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCalorimeters
dc.subjectCherenkov detectors
dc.subjectLarge detector systems for particle and astroparticle physics
dc.subjectAstroparticle physics
dc.subjectBeam-lines
dc.subjectCherenkov
dc.subjectDetector design
dc.subjectDetector systems
dc.subjectLarge detector system for particle and astroparticle physic
dc.subjectLarge detectors
dc.subjectPerformance
dc.subjectSampling calorimeters
dc.titleThe very forward CASTOR calorimeter of the CMS experiment
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus15
rdl.oa.statusgold
rdl.source.indexSCOPUS