Experimental evaluation and modeling of corroded reinforced concrete columns

ArticleAçık Erişim

Özet

A total of 30 full-scale reinforced concrete (RC) columns were tested to develop models for the prediction of the structural behavior of corroded RC columns. Of these, 25 RC columns were tested under cyclic loading for two different applied axial load ratios-namely, 0.20 and 0.40-at three concrete strength levels-namely, 9, 27, and 37 MPa (1305, 3915, and 5365 psi)-and at four corrosion levels. Five RC columns were loaded monotonically with an axial load ratio of 0.20 at four corrosion levels to calculate the damage index. The actual corrosion levels were obtained by breaking the concrete and extracting all the reinforcing bars. The test results demonstrated that the ductility ratios of the corroded RC columns, which were not determined in accordance with energy-based or bilateral failure criteria, could be misleading. The determined energy dissipation capacity and damage index of the columns further revealed the corrosion effects. © 2020 American Concrete Institute. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13558Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.14359/51721372Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYalciner, Hakan
dc.contributor.authorKumbasaroglu, Atila
dc.date.accessioned2026-10-18T20:28:23.581456676Z
dc.date.available2026-10-18T20:28:23.581456676Z
dc.date.issued2020
dc.description.abstractA total of 30 full-scale reinforced concrete (RC) columns were tested to develop models for the prediction of the structural behavior of corroded RC columns. Of these, 25 RC columns were tested under cyclic loading for two different applied axial load ratios-namely, 0.20 and 0.40-at three concrete strength levels-namely, 9, 27, and 37 MPa (1305, 3915, and 5365 psi)-and at four corrosion levels. Five RC columns were loaded monotonically with an axial load ratio of 0.20 at four corrosion levels to calculate the damage index. The actual corrosion levels were obtained by breaking the concrete and extracting all the reinforcing bars. The test results demonstrated that the ductility ratios of the corroded RC columns, which were not determined in accordance with energy-based or bilateral failure criteria, could be misleading. The determined energy dissipation capacity and damage index of the columns further revealed the corrosion effects. © 2020 American Concrete Institute. All rights reserved.
dc.description.sponsorshipThis research was supported by the Scientific and Technological Council of Turkey, under program TÜBİTAK-3501 (grant number 116M162). The authors wish to express their gratitude and appreciation for the financial support.
dc.identifier.doi10.14359/51721372
dc.identifier.eissn1944-7361
dc.identifier.endpage76
dc.identifier.issn0889-3241
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85088891282
dc.identifier.startpage61
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13558
dc.identifier.volume117
dc.identifier.wosWOS:000546684400006
dc.language.isoen
dc.publisherAmerican Concrete Institute
dc.relation.ispartofACI Structural Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAssessment
dc.subjectColumn
dc.subjectCorrosion
dc.subjectReinforcement bar
dc.subjectSeismic
dc.subjectAxial loads
dc.subjectConcrete construction
dc.subjectConcrete testing
dc.subjectCorrosive effects
dc.subjectDamage detection
dc.subjectEnergy dissipation
dc.subjectAxial load ratio
dc.subjectConcrete strength
dc.subjectCorrosion effects
dc.subjectEnergy dissipation capacities
dc.subjectExperimental evaluation
dc.subjectFailure criteria
dc.subjectReinforced concrete column
dc.subjectStructural behaviors
dc.subjectReinforced concrete
dc.titleExperimental evaluation and modeling of corroded reinforced concrete columns
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus68
rdl.citation.wos61
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)