Comparison of thalamus volume on magnetic resonance and cadaveric section images
Özet
AIM: To measure and to compare the volume of thalamus using magnetic resonance imaging (MRI) and the anatomical sections. MATERIAL and METHODS: In this study, 13 brain specimens were used. First, the images were taken in 3 mm sections on MRI, the thickness of the thalamus was measured. Subsequently, 4 mm coronal sections were prepared using a microtome. The thalamic volumes calculated from cadaveric specimens were compared with the measurements obtained using MRI. RESULTS: On MRI, the mean thalamic volumes on the right and left hemispheres were found to be 5843.4 ± 361.6 mm3 and 5377.0 ± 666.2 mm3 respectively. The mean volumes of the cadaveric sections were 5610.8 ± 401.3 mm3 on the right side and 5618.5 ± 604.1 mm3 on the left hemisphere. No statistically significant difference was found between the volume calculated from MRI and that obtained from the cadaveric section (p<0.05). CONCLUSION: This study shows a correlation between measurement of thalamus volume based on MRI and those calculated from anatomical sections. Our findings support the reliability of DBS procedures using MRI and stereotactic method. © 2020 Turkish Neurosurgical Society.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kayaci, Selim | |
| dc.contributor.author | Bas, Orhan | |
| dc.contributor.author | Celiker, Fatma Beyazal | |
| dc.contributor.author | Ucuncu, Yilmaz | |
| dc.contributor.author | Arslan, Yusuf Kemal | |
| dc.contributor.author | Ozveren, Mehmet Faik | |
| dc.contributor.author | Aykol, Sukru | |
| dc.date.accessioned | 2026-10-18T20:28:26.662521754Z | |
| dc.date.available | 2026-10-18T20:28:26.662521754Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | AIM: To measure and to compare the volume of thalamus using magnetic resonance imaging (MRI) and the anatomical sections. MATERIAL and METHODS: In this study, 13 brain specimens were used. First, the images were taken in 3 mm sections on MRI, the thickness of the thalamus was measured. Subsequently, 4 mm coronal sections were prepared using a microtome. The thalamic volumes calculated from cadaveric specimens were compared with the measurements obtained using MRI. RESULTS: On MRI, the mean thalamic volumes on the right and left hemispheres were found to be 5843.4 ± 361.6 mm3 and 5377.0 ± 666.2 mm3 respectively. The mean volumes of the cadaveric sections were 5610.8 ± 401.3 mm3 on the right side and 5618.5 ± 604.1 mm3 on the left hemisphere. No statistically significant difference was found between the volume calculated from MRI and that obtained from the cadaveric section (p<0.05). CONCLUSION: This study shows a correlation between measurement of thalamus volume based on MRI and those calculated from anatomical sections. Our findings support the reliability of DBS procedures using MRI and stereotactic method. © 2020 Turkish Neurosurgical Society. | |
| dc.identifier.doi | 10.5137/1019-5149.jtn.24530-18.2 | |
| dc.identifier.endpage | 500 | |
| dc.identifier.issn | 1019-5149 | |
| dc.identifier.issue | 4 | |
| dc.identifier.pmid | 30649832 | |
| dc.identifier.scopus | 2-s2.0-85088156148 | |
| dc.identifier.startpage | 491 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/13609 | |
| dc.identifier.volume | 30 | |
| dc.language.iso | en | |
| dc.publisher | Turkish Neurosurgical Society | |
| dc.relation.ispartof | Turkish Neurosurgery | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Cadaver | |
| dc.subject | Deep brain stimulation | |
| dc.subject | Magnetic resonance imaging | |
| dc.subject | Planimetry technique | |
| dc.subject | Thalamus | |
| dc.subject | Female | |
| dc.subject | Histological Techniques | |
| dc.subject | Humans | |
| dc.subject | Imaging, Three-Dimensional | |
| dc.subject | Male | |
| dc.subject | Organ Size | |
| dc.subject | Reproducibility of Results | |
| dc.subject | anatomy and histology | |
| dc.subject | comparative study | |
| dc.subject | histology | |
| dc.subject | human | |
| dc.subject | nuclear magnetic resonance imaging | |
| dc.subject | procedures | |
| dc.subject | reproducibility | |
| dc.subject | three-dimensional imaging | |
| dc.title | Comparison of thalamus volume on magnetic resonance and cadaveric section images | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 2 | |
| rdl.citation.trdizin | 0 | |
| rdl.department | ORDU ÜNİVERSİTESİ | |
| rdl.department | ERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ | |
| rdl.department | RECEP TAYYİP ERDOĞAN ÜNİVERSİTESİ | |
| rdl.department | KIRIKKALE ÜNİVERSİTESİ | |
| rdl.department | GAZİ ÜNİVERSİTESİ | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | TRDIZIN | |
| rdl.source.index | PUBMED |
