Nano-hydroxyapatite airborne-particle abrasion system as an alternative surface treatme method on intraorally contaminated titanium discs

ArticleAçık Erişim

Özet

The aim of this study was to test the nano-hydroxyapatite powder decontamination method on intraorally contaminated titanium discs and to compare this method with current decontamination methods in the treatment of peri-implantitis. Contaminated discs were assigned to six treatment groups (n = 10 each): titanium hand curette; ultrasonic scaler with a plastic tip (appropriate for titanium); ultrasonic scaler with a plastic tip (appropriate for titanium) + H2O2; short-term airflow system (nano-hydroxyapatite airborne-particle abrasion for 30 seconds); long-term airflow system (nano-hydroxyapatite airborne-particle abrasion for 120 seconds); Er:YAG laser (120 mJ/pulse at 10 Hz). There were also two control groups (n = 10 each): contaminated disc (negative control) and sterile disc (positive control). Scanning electron microscopy, energy-dispersive x-ray spectroscopy, and dynamic contact angle analysis were used to determine the most effective surface-treatment method. The highest percentage of carbon (C) atoms was observed in the negative control group, and the lowest percentage of C atoms was found in the long-term airflow group, followed by the short-term airflow, laser, ultrasonic + H2O2, ultrasonic, and mechanical groups. When the groups were examined for wettability, the lowest contact angle degree was observed in the long-term airflow, short-term airflow, and laser groups. Nano-hydroxyapatite and laser treatments for detoxifying and improving infected titanium surfaces may show the most suitable results for reosseointegration. © 2020 by Quintessence Publishing Co Inc.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13685Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.11607/prd.4852Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorGümüş, Kerem Çağlar
dc.contributor.authorUstaoğlu, Gülbahar
dc.contributor.authorKara, Levent
dc.contributor.authorErcan, Esra
dc.contributor.authorAlbayrak, Önder
dc.contributor.authorTunali, Mustafa
dc.date.accessioned2026-10-18T20:28:31.011712131Z
dc.date.available2026-10-18T20:28:31.011712131Z
dc.date.issued2020
dc.description.abstractThe aim of this study was to test the nano-hydroxyapatite powder decontamination method on intraorally contaminated titanium discs and to compare this method with current decontamination methods in the treatment of peri-implantitis. Contaminated discs were assigned to six treatment groups (n = 10 each): titanium hand curette; ultrasonic scaler with a plastic tip (appropriate for titanium); ultrasonic scaler with a plastic tip (appropriate for titanium) + H2O2; short-term airflow system (nano-hydroxyapatite airborne-particle abrasion for 30 seconds); long-term airflow system (nano-hydroxyapatite airborne-particle abrasion for 120 seconds); Er:YAG laser (120 mJ/pulse at 10 Hz). There were also two control groups (n = 10 each): contaminated disc (negative control) and sterile disc (positive control). Scanning electron microscopy, energy-dispersive x-ray spectroscopy, and dynamic contact angle analysis were used to determine the most effective surface-treatment method. The highest percentage of carbon (C) atoms was observed in the negative control group, and the lowest percentage of C atoms was found in the long-term airflow group, followed by the short-term airflow, laser, ultrasonic + H2O2, ultrasonic, and mechanical groups. When the groups were examined for wettability, the lowest contact angle degree was observed in the long-term airflow, short-term airflow, and laser groups. Nano-hydroxyapatite and laser treatments for detoxifying and improving infected titanium surfaces may show the most suitable results for reosseointegration. © 2020 by Quintessence Publishing Co Inc.
dc.identifier.doi10.11607/prd.4852
dc.identifier.eissn1945-3388
dc.identifier.endpageE187
dc.identifier.issn0198-7569
dc.identifier.issue4
dc.identifier.pmid32559046
dc.identifier.scopus2-s2.0-85086754469
dc.identifier.startpageE179
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13685
dc.identifier.volume40
dc.identifier.wosWOS:000542153700006
dc.language.isoen
dc.publisherQuintessence Publishing Co. Inc.
dc.relation.ispartofInternational Journal of Periodontics and Restorative Dentistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDental Implants
dc.subjectDurapatite
dc.subjectHydrogen Peroxide
dc.subjectMicroscopy, Electron, Scanning
dc.subjectSurface Properties
dc.subjectTitanium
dc.subjectcalcium phosphate
dc.subjectcarbon
dc.subjecthydroxyapatite
dc.subjectnanoparticle
dc.subjectplastic
dc.subjectdistilled water
dc.subjectnanohydroxyapatite
dc.subjectpolyetheretherketone
dc.subjectairborne particle
dc.subjectairflow
dc.subjectArticle
dc.subjectbiomechanics
dc.subjectcontact angle
dc.subjectcontamination
dc.subjectcontrolled study
dc.subjectdecontamination
dc.subjectdynamics
dc.subjectenergy dispersive X ray spectroscopy
dc.subjectfemale
dc.subjecthand
dc.subjecthuman
dc.subjecthuman experiment
dc.subjectlow level laser therapy
dc.subjectmale
dc.titleNano-hydroxyapatite airborne-particle abrasion system as an alternative surface treatme method on intraorally contaminated titanium discs
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos4
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)