Voltammetric Determination of Isoniazid Drug in Various Matrix by Using CuOx Decorated MW-CNT Modified Glassy Carbon Electrode

ArticleAçık Erişim

Özet

Copper oxide decorated multi-walled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) was prepared for determination of isoniazid (INZ) in various matrices. The electrochemical behavior of INZ was tested with the aid of Cyclic Voltammetry (CV) and quantitative experiments were performed by using Linear Sweep Voltammetry (LSV). Morphological and structural characterization of the modified electrode was performed by utilizing Scanning Electron Microscopy (SEM), X-Ray Photoelectron Spectroscopy (XPS) while electrochemical characterization was performed by using CV and Electrochemical Impedance spectroscopy (EIS). The proposed sensor exhibited well defined anodic peak at 0.30 V for INZ at pH 6.0 medium. Under the optimum conditions, a linear relation between INZ concentration and peak current was observed in the range of 2.0×10−7 to 5.0×10−5 M. Limit of detection was calculated as 1.0×10−8 M and repeatability and accuracy was found as 5.60 % and 91.0 % for 5.0 10−7 M INZ by using 3 successive measurement, respectively. Then, the analytic performance of the electrode developed was tested by analyzing commercial tablets, artificial human serum and urine samples. The results indicated that satisfactory recoveries was observed for all issue. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13772Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/elan.201900307Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÖzdokur, K. Volkan
dc.date.accessioned2026-10-18T20:28:35.476744359Z
dc.date.available2026-10-18T20:28:35.476744359Z
dc.date.issued2020
dc.description.abstractCopper oxide decorated multi-walled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) was prepared for determination of isoniazid (INZ) in various matrices. The electrochemical behavior of INZ was tested with the aid of Cyclic Voltammetry (CV) and quantitative experiments were performed by using Linear Sweep Voltammetry (LSV). Morphological and structural characterization of the modified electrode was performed by utilizing Scanning Electron Microscopy (SEM), X-Ray Photoelectron Spectroscopy (XPS) while electrochemical characterization was performed by using CV and Electrochemical Impedance spectroscopy (EIS). The proposed sensor exhibited well defined anodic peak at 0.30 V for INZ at pH 6.0 medium. Under the optimum conditions, a linear relation between INZ concentration and peak current was observed in the range of 2.0×10−7 to 5.0×10−5 M. Limit of detection was calculated as 1.0×10−8 M and repeatability and accuracy was found as 5.60 % and 91.0 % for 5.0 10−7 M INZ by using 3 successive measurement, respectively. Then, the analytic performance of the electrode developed was tested by analyzing commercial tablets, artificial human serum and urine samples. The results indicated that satisfactory recoveries was observed for all issue. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
dc.identifier.doi10.1002/elan.201900307
dc.identifier.eissn1521-4109
dc.identifier.endpage495
dc.identifier.issn1040-0397
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85074750898
dc.identifier.startpage489
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13772
dc.identifier.volume32
dc.identifier.wosWOS:000517823800005
dc.language.isoen
dc.publisherWiley-VCH Verlag
dc.relation.ispartofElectroanalysis
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCuOx decorated MW-CNT
dc.subjectelectrochemical sensor
dc.subjectIsoniazid
dc.subjectCopper oxides
dc.subjectElectrochemical impedance spectroscopy
dc.subjectElectrochemical sensors
dc.subjectGlass
dc.subjectGlass membrane electrodes
dc.subjectHydrazine
dc.subjectMatrix algebra
dc.subjectMultiwalled carbon nanotubes (MWCN)
dc.subjectScanning electron microscopy
dc.subjectX ray photoelectron spectroscopy
dc.subjectElectrochemical behaviors
dc.subjectLinear sweep voltammetry
dc.subjectmatrix
dc.subjectModified glassy carbon electrode
dc.subjectMorphological characterization
dc.subjectMulti-walled-carbon-nanotubes
dc.subjectQuantitative experiments
dc.subjectVoltammetric determination
dc.subjectCyclic voltammetry
dc.titleVoltammetric Determination of Isoniazid Drug in Various Matrix by Using CuOx Decorated MW-CNT Modified Glassy Carbon Electrode
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus21
rdl.citation.wos17
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)