The effect of enhancement factor on the angular dependence of L x-ray intensity ratios for Sm, Hf, Pb and U
ArticleAçık Erişim
Özet
The effect of enhancement factor on the angular dependence of Ll/Lγ, Lα/Lγ and Lβ/Lγ X-ray intensity ratios for Sm, Hf, Pb and U elements have been measured by using the 59.54 keV photon energy. The binary systems are prepared as Sm-CeO2, Hf-CeO2, Pb–CeO2 and U–CeO2. The samples have been analyzed in EDXRF system. The measurements are made in scattering angles of 85°, 95°, 105°, 115° and 125°. The L X-ray spectra from different samples were detected by a Si(Li) detector. The results show that the intensity ratios of L X-rays to be greater than expected due to the enhancement effect. © 2019 Elsevier Ltd
Anahtar Kelimeler
Angular dependenceEnhancement factorL X-raysCerium oxideEnergy dispersive spectroscopyX rayshafniumleadsamariumuraniumBinary systemsEnhancement effectsIntensity ratioScattering anglesX-ray intensity ratiosArticlefluorescencegamma radiationgeometryphotonradiation scatteringradiological parametersX rayX ray detectors
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13819Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Akkuş, Tuba | |
| dc.contributor.author | Yılmaz, Demet | |
| dc.contributor.author | Uğurlu, Mine | |
| dc.date.accessioned | 2026-10-18T20:28:37.693075427Z | |
| dc.date.available | 2026-10-18T20:28:37.693075427Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | The effect of enhancement factor on the angular dependence of Ll/Lγ, Lα/Lγ and Lβ/Lγ X-ray intensity ratios for Sm, Hf, Pb and U elements have been measured by using the 59.54 keV photon energy. The binary systems are prepared as Sm-CeO2, Hf-CeO2, Pb–CeO2 and U–CeO2. The samples have been analyzed in EDXRF system. The measurements are made in scattering angles of 85°, 95°, 105°, 115° and 125°. The L X-ray spectra from different samples were detected by a Si(Li) detector. The results show that the intensity ratios of L X-rays to be greater than expected due to the enhancement effect. © 2019 Elsevier Ltd | |
| dc.identifier.doi | 10.1016/j.radphyschem.2019.108499 | |
| dc.identifier.eissn | 1879-0895 | |
| dc.identifier.issn | 0969-806X | |
| dc.identifier.scopus | 2-s2.0-85072680684 | |
| dc.identifier.startpage | 108499 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/13819 | |
| dc.identifier.volume | 166 | |
| dc.identifier.wos | WOS:000501394400025 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Ltd | |
| dc.relation.ispartof | Radiation Physics and Chemistry | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Angular dependence | |
| dc.subject | Enhancement factor | |
| dc.subject | L X-rays | |
| dc.subject | Cerium oxide | |
| dc.subject | Energy dispersive spectroscopy | |
| dc.subject | X rays | |
| dc.subject | hafnium | |
| dc.subject | lead | |
| dc.subject | samarium | |
| dc.subject | uranium | |
| dc.subject | Binary systems | |
| dc.subject | Enhancement effects | |
| dc.subject | Intensity ratio | |
| dc.subject | Scattering angles | |
| dc.subject | X-ray intensity ratios | |
| dc.subject | Article | |
| dc.subject | fluorescence | |
| dc.subject | gamma radiation | |
| dc.subject | geometry | |
| dc.subject | photon | |
| dc.subject | radiation scattering | |
| dc.subject | radiological parameters | |
| dc.subject | X ray | |
| dc.subject | X ray detectors | |
| dc.title | The effect of enhancement factor on the angular dependence of L x-ray intensity ratios for Sm, Hf, Pb and U | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 0 | |
| rdl.citation.wos | 0 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
