Pulsed Deposited Manganese and Vanadium Oxide Film Modified with Carbon Nanotube and Gold Nanoparticle: Chitosan and Ionic Liquid-based Biosensor

ArticleAçık Erişim

Özet

Present study describes the synthesis of mixed oxide films of manganese and vanadium by electrochemical pulsed deposition technique on a glassy carbon electrode (GCE) modified with multiwall carbon nanotubes (MWCNT). The film was further decorated with gold nanoparticles to enhance the reduction signal of dissolved oxygen in pH 5.17 acetate buffer solution. All of the electrochemical synthesized modified electrodes have been characterized with Scanning electron microscopy(SEM), High-resolution transmission electron microscopy (HRTEM), X-Ray photoelectron spectroscopy (XPS), X-Ray diffraction (XRD) techniques. The electrode obtained (AuNPs/MnOx−VOx/CNT/GCE) was utilized as a platform for glucose biosensor where the glucose oxidase enzyme was immobilized on the composite film with the aid of chitosan and an ionic liquid. The electrochemical performance of the biosensor was investigated by cyclic voltammetry and the relative parameters have been optimized by amperometric measurements in pH 5.17 acetate buffer solution. The developed biosensor exhibited a linear range for glucose between 0.1–1.0 mM and the limit of detection was calculated as 0.02 mM. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13852Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/elan.201900194Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkoğulları, Seçil
dc.contributor.authorÇιnar, Seda
dc.contributor.authorÖzdokur, Kemal Volkan
dc.contributor.authorAydemir, Tülin
dc.contributor.authorErtaş, Fatma Nil
dc.contributor.authorKoçak, Süleyman
dc.date.accessioned2026-10-18T20:28:39.324183077Z
dc.date.available2026-10-18T20:28:39.324183077Z
dc.date.issued2020
dc.description.abstractPresent study describes the synthesis of mixed oxide films of manganese and vanadium by electrochemical pulsed deposition technique on a glassy carbon electrode (GCE) modified with multiwall carbon nanotubes (MWCNT). The film was further decorated with gold nanoparticles to enhance the reduction signal of dissolved oxygen in pH 5.17 acetate buffer solution. All of the electrochemical synthesized modified electrodes have been characterized with Scanning electron microscopy(SEM), High-resolution transmission electron microscopy (HRTEM), X-Ray photoelectron spectroscopy (XPS), X-Ray diffraction (XRD) techniques. The electrode obtained (AuNPs/MnOx−VOx/CNT/GCE) was utilized as a platform for glucose biosensor where the glucose oxidase enzyme was immobilized on the composite film with the aid of chitosan and an ionic liquid. The electrochemical performance of the biosensor was investigated by cyclic voltammetry and the relative parameters have been optimized by amperometric measurements in pH 5.17 acetate buffer solution. The developed biosensor exhibited a linear range for glucose between 0.1–1.0 mM and the limit of detection was calculated as 0.02 mM. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
dc.description.sponsorshipThis study was supported by Manisa Celal Bayar University Research Foundation Project No: 2017‐018.
dc.identifier.doi10.1002/elan.201900194
dc.identifier.eissn1521-4109
dc.identifier.endpage453
dc.identifier.issn1040-0397
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85072062619
dc.identifier.startpage445
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13852
dc.identifier.volume32
dc.identifier.wosWOS:000486003100001
dc.language.isoen
dc.publisherWiley-VCH Verlag
dc.relation.ispartofElectroanalysis
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectglucose
dc.subjectGold nanoparticles
dc.subjectmanganese and vanadium oxide
dc.subjectoxygen
dc.subjectpulsed deposition
dc.subjectCarbon films
dc.subjectChitosan
dc.subjectCyclic voltammetry
dc.subjectDeposition
dc.subjectDissolved oxygen
dc.subjectFiber optic sensors
dc.subjectGlass membrane electrodes
dc.subjectGlucose oxidase
dc.subjectGlucose sensors
dc.subjectGold compounds
dc.subjectGold deposits
dc.subjectHigh resolution transmission electron microscopy
dc.subjectIonic liquids
dc.subjectMetal nanoparticles
dc.subjectMultiwalled carbon nanotubes (MWCN)
dc.subjectNanocomposite films
dc.subjectOxide films
dc.subjectOxides
dc.subjectScanning electron microscopy
dc.subjectVanadium compounds
dc.subjectX ray photoelectron spectroscopy
dc.subjectYarn
dc.subjectAcetate buffer solutions
dc.subjectCarbon nanotube nanoparticles
dc.subjectElectrochemicals
dc.titlePulsed Deposited Manganese and Vanadium Oxide Film Modified with Carbon Nanotube and Gold Nanoparticle: Chitosan and Ionic Liquid-based Biosensor
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus12
rdl.citation.wos13
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)