Construction of a novel highly selective potentiometric perchlorate sensor based on neocuproine-Cu(II) complex formed in situ during the conditioning period
Özet
A potentiometric perchlorate-selective electrode based on a phenanthroline derivative, neocuproine (2,9-dimethyl-1,10-phenanthroline), was developed. An electroactive substance, a neocuproine complex of Cu2+, providing a selective response to perchlorate was formed in situ in the electrode membrane structure during the conditioning process. Membrane optimization studies showed that the most suitable membrane composition was 1.0% (w/w) neocuproine, 69.0% (w/w) o-nitrophenyloctylether (o-NPOE) and 30.0% (w/w) poly(vinyl chloride) (PVC) in terms of potentiometric performance characteristics. For the proposed electrode, the linear range, slope, detection limit, pH working range and response time were determined as 2.5 × 10-7-1.0 × 10-1 M, -53.01 mV/decade, 1.0 × 10-7 M, 4.0-12.5 and ≈3 s, respectively. The proposed sensor was successfully used in the determination of perchlorate contents of some perchlorate spiked tap, river and dam water samples. © Lietuvos mokslu akademija, 2018.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Onder, Ahmet | |
| dc.contributor.author | Topcu, Cihan | |
| dc.contributor.author | Coldur, Fatih | |
| dc.date.accessioned | 2026-10-18T20:28:53.771717886Z | |
| dc.date.available | 2026-10-18T20:28:53.771717886Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | A potentiometric perchlorate-selective electrode based on a phenanthroline derivative, neocuproine (2,9-dimethyl-1,10-phenanthroline), was developed. An electroactive substance, a neocuproine complex of Cu2+, providing a selective response to perchlorate was formed in situ in the electrode membrane structure during the conditioning process. Membrane optimization studies showed that the most suitable membrane composition was 1.0% (w/w) neocuproine, 69.0% (w/w) o-nitrophenyloctylether (o-NPOE) and 30.0% (w/w) poly(vinyl chloride) (PVC) in terms of potentiometric performance characteristics. For the proposed electrode, the linear range, slope, detection limit, pH working range and response time were determined as 2.5 × 10-7-1.0 × 10-1 M, -53.01 mV/decade, 1.0 × 10-7 M, 4.0-12.5 and ≈3 s, respectively. The proposed sensor was successfully used in the determination of perchlorate contents of some perchlorate spiked tap, river and dam water samples. © Lietuvos mokslu akademija, 2018. | |
| dc.identifier.endpage | 66 | |
| dc.identifier.issn | 0235-7216 | |
| dc.identifier.issue | 1 | |
| dc.identifier.scopus | 2-s2.0-85045901655 | |
| dc.identifier.startpage | 57 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/14116 | |
| dc.identifier.volume | 29 | |
| dc.language.iso | en | |
| dc.publisher | Lietuvos Mokslu Akademijos | |
| dc.relation.ispartof | Chemija | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Electrode | |
| dc.subject | Neocuproine | |
| dc.subject | Perchlorate | |
| dc.subject | Perchlorate determination | |
| dc.subject | Potentiometry | |
| dc.title | Construction of a novel highly selective potentiometric perchlorate sensor based on neocuproine-Cu(II) complex formed in situ during the conditioning period | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 7 | |
| rdl.source.index | SCOPUS |
