Effects of two different contact lenses on ocular physiological parameters and tear function tests; [Efeitos de duas lentes de contacto diferentes nos parâmetros fisiológicos oculares e nos testes de função lacrimal]

ArticleAçık Erişim

Özet

Objective: To investigate the effects of two types of contact lenses made of two different types of silicone hydrogel material on ocular physiological parameters and tear function tests. Methods: The contact lenses with the appropriate diopters were supplied to the volunteering patients. The patients were evaluated before wearing the contact lenses (visit0:V0), at the first month(visit1:V1) and at the thirth month(visit2:V2) following their wear. At all visits a detailed biomicroscopic examination was done, ocular physiological variables were collected, the tear function tests were performed and the tear meniscus area (TMA) was visualized and measured with anterior segment optical coherence tomography (AS-OCT). Results: The results of Schirmer 1 test were 12.07 ± 1.51 [9-16] mm for the right eyes (samfilcon A group) and 12.09 ± 1.5 [9-16] mm for the left eyes (senofilcon A group) at V0. (p=0.950) At V2, the mean Schirmer 1 test results were 11.92±1.34 [9-15] mm in the samfilcon A group and 12.2±1.41 [9-16] mm in the senofilcon A group (p=0.239). The mean TMA dimensions in the AS-OCT images were 338.42±47.1 [241-401] microns in the samfilcon A group and 338.42±47.1 [241-401] microns in the senofilcon A group at V0. (p>0.05). At V2, the mean TMA dimensions were 337.2±45.53 [241-402] microns in the samfilcon A group and 340.31±48.22 [240-411] microns in the senofilcon A group (p=0.728). Conclusions: Our study has demonstrated that contact lenses containing samfilcon A and senofilcon A silicone hydrogel material do not cause meaningful ocular surface problems © 2019. Revista Brasileira de Oftalmologia. All Rights Reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/14159Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.5935/0034-7280.20190168Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorUgurlu, Adem
dc.contributor.authorUcak, Turgay
dc.contributor.authorKarakurt, Yucel
dc.contributor.authorTasli, Nurdan Gamze
dc.contributor.authorIcel, Erel
dc.contributor.authorYılmaz, Hayati
dc.date.accessioned2026-10-18T20:28:56.725325040Z
dc.date.available2026-10-18T20:28:56.725325040Z
dc.date.issued2019
dc.description.abstractObjective: To investigate the effects of two types of contact lenses made of two different types of silicone hydrogel material on ocular physiological parameters and tear function tests. Methods: The contact lenses with the appropriate diopters were supplied to the volunteering patients. The patients were evaluated before wearing the contact lenses (visit0:V0), at the first month(visit1:V1) and at the thirth month(visit2:V2) following their wear. At all visits a detailed biomicroscopic examination was done, ocular physiological variables were collected, the tear function tests were performed and the tear meniscus area (TMA) was visualized and measured with anterior segment optical coherence tomography (AS-OCT). Results: The results of Schirmer 1 test were 12.07 ± 1.51 [9-16] mm for the right eyes (samfilcon A group) and 12.09 ± 1.5 [9-16] mm for the left eyes (senofilcon A group) at V0. (p=0.950) At V2, the mean Schirmer 1 test results were 11.92±1.34 [9-15] mm in the samfilcon A group and 12.2±1.41 [9-16] mm in the senofilcon A group (p=0.239). The mean TMA dimensions in the AS-OCT images were 338.42±47.1 [241-401] microns in the samfilcon A group and 338.42±47.1 [241-401] microns in the senofilcon A group at V0. (p>0.05). At V2, the mean TMA dimensions were 337.2±45.53 [241-402] microns in the samfilcon A group and 340.31±48.22 [240-411] microns in the senofilcon A group (p=0.728). Conclusions: Our study has demonstrated that contact lenses containing samfilcon A and senofilcon A silicone hydrogel material do not cause meaningful ocular surface problems © 2019. Revista Brasileira de Oftalmologia. All Rights Reserved.
dc.identifier.doi10.5935/0034-7280.20190168
dc.identifier.endpage398
dc.identifier.issn0034-7280
dc.identifier.issue6
dc.identifier.scopus2-s2.0-85120940836
dc.identifier.startpage394
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/14159
dc.identifier.volume78
dc.language.isoen
dc.publisherSociedade Brasileira de Oftalmologia
dc.relation.ispartofRevista Brasileira de Oftalmologia
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectContact lens
dc.subjectOcular physiological phenomena
dc.subjectSilicone geis
dc.subjectTears
dc.titleEffects of two different contact lenses on ocular physiological parameters and tear function tests; [Efeitos de duas lentes de contacto diferentes nos parâmetros fisiológicos oculares e nos testes de função lacrimal]
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.source.indexSCOPUS