Biomechanical comparison of three different fixation techniques for anterior column posterior hemitransverse acetabular fractures using anterior intrapelvic approach

ArticleAçık Erişim

Özet

Objectives: The aim of this study was to biomechanically compare three different fixation methods for the fixation of anterior column posterior hemitransverse type acetabular fracture (ACPHT). Methods: ACPHT fracture models were created on twenty-four foam cortical shell artificial hemipelvis models. Three fixation methods were assessed - Group 1: posterior column lag screws over a suprapectineal plate; Group 2: Posterior column lag screws over a suprapectineal plate and an infrapectineal plate; Group 3: A suprapectineal plate and a vertical infrapectineal plate. Stiffness and displacement amounts of fixation methods under dynamic and static axial loading conditions were measured. Results: In the dynamic and static tests, Group 3 showed the less stable fixation compared to Group 2. There was no statistically significant difference between the stiffness values of the fixation groups. In the static tests, there was no statistically significant difference between Group 1 and 2, although less displacements were obtained in Group 2. Conclusions: A combination of posterior lag screws over a suprapectineal plate and an infrapectineal plate supporting the pelvic brim along both sides of the linea terminalis resulted in a better fixation construct than a suprapectineal plate accompanying with a vertical infrapectineal plate provide better stability with less fracture displacement. © 2018 Elsevier Ltd

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/14439Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTanoğlu, Oğuzhan
dc.contributor.authorAlemdaroğlu, Kadir Bahadır
dc.contributor.authorİltar, Serkan
dc.contributor.authorÖzmeriç, Ahmet
dc.contributor.authorDemir, Teyfik
dc.contributor.authorErbay, Fatma Kübra
dc.date.accessioned2026-10-18T20:29:14.058560377Z
dc.date.available2026-10-18T20:29:14.058560377Z
dc.date.issued2018
dc.description.abstractObjectives: The aim of this study was to biomechanically compare three different fixation methods for the fixation of anterior column posterior hemitransverse type acetabular fracture (ACPHT). Methods: ACPHT fracture models were created on twenty-four foam cortical shell artificial hemipelvis models. Three fixation methods were assessed - Group 1: posterior column lag screws over a suprapectineal plate; Group 2: Posterior column lag screws over a suprapectineal plate and an infrapectineal plate; Group 3: A suprapectineal plate and a vertical infrapectineal plate. Stiffness and displacement amounts of fixation methods under dynamic and static axial loading conditions were measured. Results: In the dynamic and static tests, Group 3 showed the less stable fixation compared to Group 2. There was no statistically significant difference between the stiffness values of the fixation groups. In the static tests, there was no statistically significant difference between Group 1 and 2, although less displacements were obtained in Group 2. Conclusions: A combination of posterior lag screws over a suprapectineal plate and an infrapectineal plate supporting the pelvic brim along both sides of the linea terminalis resulted in a better fixation construct than a suprapectineal plate accompanying with a vertical infrapectineal plate provide better stability with less fracture displacement. © 2018 Elsevier Ltd
dc.description.sponsorshipWe would like to thank to Turkish Society of Orthopaedics and Traumatology (TSOT) and Turkish Orthopaedics Research Council (TORC) for the funding of this research.
dc.identifier.doi10.1016/j.injury.2018.06.020
dc.identifier.eissn1879-0267
dc.identifier.endpage1519
dc.identifier.issn0020-1383
dc.identifier.issue8
dc.identifier.pmid29934096
dc.identifier.scopus2-s2.0-85048725535
dc.identifier.startpage1513
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/14439
dc.identifier.volume49
dc.identifier.wosWOS:000441896100025
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofInjury
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBiomechanical
dc.subjectDynamic loading
dc.subjectInfrapectineal plate
dc.subjectStatic loading
dc.subjectStiffness
dc.subjectStoppa
dc.subjectSuprapectineal plate
dc.subjectAcetabulum
dc.subjectArtificial Organs
dc.subjectBiomechanical Phenomena
dc.subjectBone Plates
dc.subjectBone Screws
dc.subjectEquipment Design
dc.subjectFracture Fixation, Internal
dc.subjectFractures, Bone
dc.subjectHumans
dc.subjectJoint Instability
dc.subjectMaterials Testing
dc.subjectPelvis
dc.subjectSimulation Training
dc.subjectStress, Mechanical
dc.subjectWeight-Bearing
dc.subjectacetabulum fracture
dc.subjectadult
dc.subjectArticle
dc.subjectbiomechanics
dc.subjectcolumn posterior hemitransverse acetabular fracture
dc.subjectcomparative study
dc.subjectcontrolled study
dc.subjectfracture fixation
dc.titleBiomechanical comparison of three different fixation techniques for anterior column posterior hemitransverse acetabular fractures using anterior intrapelvic approach
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus21
rdl.citation.wos21
rdl.departmentErzincan University Mengücek Gazi Training and Research Hospital, Orthopaedics and Traumatology Department, Turkey. Electronic address: drtanoglu@gmail.com.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)