Searching the effect of anodization process as a surface treatment; [Yüzey i˙şlemi olarak uygulanan anodizasyonun etkilerinin araştirilmasi]
Özet
Objective: The aim of this study was to compare the effect of anodization and air-particle abrasion surface treatments on shear bond strength between Ni-Cr and ceramics. Material and Methods: 30 cylindrical Ni-Cr specimens (7 × 10 mm) were divided into three groups according to the surface treatments [control group (no-treatment), air-particle abrasion group (110 μm Al2O3 at 75 psi from 20 cm for 30 seconds), and anodization group]. One sample from each group was evaluated by using SEM. Ceramics with a dimension (5 × 3 mm) built-up on specimens and shear bond strength tests were performed by using universal testing machine with a 1 mm/min crosshead speed. Stereomicroscope was used to evaluate the failure mode of specimens. One-way ANOVA with post-hoc Tukey's test was used to analyze the differences in shear bond strength values. Results: The shear bond strength of air-particle abrasion (21.35∓4.64) was higher than anodization group (20.92∓4.85) however, no statistically significant difference was detected (p=0.893). Both groups showed higher bond strength than control group (8.02∓1.47) (p < .05). Conclusion: The evaluation of the surface treatment methods showed that the anodization process can be used in order to increase the metal-ceramic bond strength. © 2018 Cumhuriyet University Faculty of Dentistry.; Amaç: Bu çalişmanin amaci, anodizasyon ve kumlama yüzey işlemlerinin Ni-Cr ve seramik arasindaki makaslama bağlanti dayanimi üzerine etkilerini karşilaştirmaktir. Gereç ve Yöntem: 30 adet silindir şeklinde Ni-Cr örnek (7 × 10 mm) uygulanan yüzey işlemlerine göre üç gruba ayrildi [kontrol group (hiç işlem görmedi), kumlama grubu (110 μm Al2O3, 75 psi basinçla, 20 cm uzakliktan, 30 saniye süresince) ve anodizasyon grubu]. Her gruptan birer örnek alinarak SEM analizleri gerçekleştirildi. Hazirlanan örneklerin üzerine 5 × 3 mm boyutlarinda seramikler pişirildi ve makaslama bağlanti dayanim testleri universal test cihazinda kafa hizi 1mm/dk olacak şekilde gerçekleştirildi. örneklerin kopma şekillerinin tespitinde stereomikroskop kullanildi. Makaslama bağlanti dayanim değerlerinin analizinde One-way ANOVA ve post-hoc Tukey's testleri kullanildi. Bulgular: Kumlama grubunun makaslama bağlanti dayanimi (21,35∓4,64) anodizasyon grubuna (20,92∓4,85) göre yüksek olarak bulunmasina rağmen her iki grup arasindaki farklilik istatistiksel olarak önemli bulunmamiştir (p = 0.893). Her iki grupta kontrol grubuna göre (8,02∓1,47) yüksek bağlanti dayanimina sahip olduğu tespit edilmiştir (p < 0,05). Sonuç: Yüzey uygulama metotlarinin değerlendirilmesi sonucunda anodizasyon uygulamasinin metal-seramik bağlantisinin artirilmasi için kullanilabilecek bir yöntem olduğunu tespit edilmiştir. © 2018 Cumhuriyet University Faculty of Dentistry.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Coskun, M. Emre | |
| dc.contributor.author | Akar, Turker | |
| dc.contributor.author | Bozkurt çirak, Burcu | |
| dc.date.accessioned | 2026-10-18T20:29:15.970962540Z | |
| dc.date.available | 2026-10-18T20:29:15.970962540Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | Objective: The aim of this study was to compare the effect of anodization and air-particle abrasion surface treatments on shear bond strength between Ni-Cr and ceramics. Material and Methods: 30 cylindrical Ni-Cr specimens (7 × 10 mm) were divided into three groups according to the surface treatments [control group (no-treatment), air-particle abrasion group (110 μm Al2O3 at 75 psi from 20 cm for 30 seconds), and anodization group]. One sample from each group was evaluated by using SEM. Ceramics with a dimension (5 × 3 mm) built-up on specimens and shear bond strength tests were performed by using universal testing machine with a 1 mm/min crosshead speed. Stereomicroscope was used to evaluate the failure mode of specimens. One-way ANOVA with post-hoc Tukey's test was used to analyze the differences in shear bond strength values. Results: The shear bond strength of air-particle abrasion (21.35∓4.64) was higher than anodization group (20.92∓4.85) however, no statistically significant difference was detected (p=0.893). Both groups showed higher bond strength than control group (8.02∓1.47) (p < .05). Conclusion: The evaluation of the surface treatment methods showed that the anodization process can be used in order to increase the metal-ceramic bond strength. © 2018 Cumhuriyet University Faculty of Dentistry.; Amaç: Bu çalişmanin amaci, anodizasyon ve kumlama yüzey işlemlerinin Ni-Cr ve seramik arasindaki makaslama bağlanti dayanimi üzerine etkilerini karşilaştirmaktir. Gereç ve Yöntem: 30 adet silindir şeklinde Ni-Cr örnek (7 × 10 mm) uygulanan yüzey işlemlerine göre üç gruba ayrildi [kontrol group (hiç işlem görmedi), kumlama grubu (110 μm Al2O3, 75 psi basinçla, 20 cm uzakliktan, 30 saniye süresince) ve anodizasyon grubu]. Her gruptan birer örnek alinarak SEM analizleri gerçekleştirildi. Hazirlanan örneklerin üzerine 5 × 3 mm boyutlarinda seramikler pişirildi ve makaslama bağlanti dayanim testleri universal test cihazinda kafa hizi 1mm/dk olacak şekilde gerçekleştirildi. örneklerin kopma şekillerinin tespitinde stereomikroskop kullanildi. Makaslama bağlanti dayanim değerlerinin analizinde One-way ANOVA ve post-hoc Tukey's testleri kullanildi. Bulgular: Kumlama grubunun makaslama bağlanti dayanimi (21,35∓4,64) anodizasyon grubuna (20,92∓4,85) göre yüksek olarak bulunmasina rağmen her iki grup arasindaki farklilik istatistiksel olarak önemli bulunmamiştir (p = 0.893). Her iki grupta kontrol grubuna göre (8,02∓1,47) yüksek bağlanti dayanimina sahip olduğu tespit edilmiştir (p < 0,05). Sonuç: Yüzey uygulama metotlarinin değerlendirilmesi sonucunda anodizasyon uygulamasinin metal-seramik bağlantisinin artirilmasi için kullanilabilecek bir yöntem olduğunu tespit edilmiştir. © 2018 Cumhuriyet University Faculty of Dentistry. | |
| dc.identifier.doi | 10.7126/cumudj.475207 | |
| dc.identifier.endpage | 303 | |
| dc.identifier.issn | 2146-2852 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85060518853 | |
| dc.identifier.startpage | 298 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/14455 | |
| dc.identifier.volume | 21 | |
| dc.language.iso | en | |
| dc.publisher | Cumhuriyet University Faculty of Dentistry | |
| dc.relation.ispartof | Cumhuriyet Dental Journal | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Air-particle abrasion | |
| dc.subject | Anodizasyon | |
| dc.subject | Anodization | |
| dc.subject | Kumlama | |
| dc.subject | Makaslama bağlanti dayanimi | |
| dc.subject | Ni-Cr | |
| dc.subject | Platin | |
| dc.subject | Platinum | |
| dc.subject | Shear-bond strength | |
| dc.title | Searching the effect of anodization process as a surface treatment; [Yüzey i˙şlemi olarak uygulanan anodizasyonun etkilerinin araştirilmasi] | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 2 | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS |