Mechanical stability of the CMS strip tracker measured with a laser alignment system
Özet
The CMS tracker consists of 206 m2 of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements of tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value. © CERN 2017 for the benefit of the CMS collaboration..
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Sirunyan, A.M. | |
| dc.contributor.author | Tumasyan, A. | |
| dc.contributor.author | Adam, W. | |
| dc.contributor.author | Asilar, E. | |
| dc.contributor.author | Bergauer, T. | |
| dc.contributor.author | Brandstetter, J. | |
| dc.contributor.author | Brondolin, E. | |
| dc.contributor.author | Dragicevic, M. | |
| dc.contributor.author | Erö, J. | |
| dc.contributor.author | Flechl, M. | |
| dc.contributor.author | Friedl, M. | |
| dc.contributor.author | Frühwirth, R. | |
| dc.contributor.author | Ghete, V.M. | |
| dc.contributor.author | Hoch, M. | |
| dc.contributor.author | Hartl, C. | |
| dc.contributor.author | Hörmann, N. | |
| dc.contributor.author | Hrubec, J. | |
| dc.contributor.author | Jeitler, M. | |
| dc.contributor.author | König, A. | |
| dc.contributor.author | Krätschmer, I. | |
| dc.contributor.author | Liko, D. | |
| dc.contributor.author | Matsushita, T. | |
| dc.contributor.author | Mikulec, I. | |
| dc.contributor.author | Rabady, D. | |
| dc.contributor.author | Rad, N. | |
| dc.contributor.author | Rahbaran, B. | |
| dc.contributor.author | Rohringer, H. | |
| dc.contributor.author | Schieck, J. | |
| dc.contributor.author | Strauss, J. | |
| dc.contributor.author | Waltenberger, W. | |
| dc.contributor.author | Wulz, C.-E. | |
| dc.contributor.author | Dvornikov, O. | |
| dc.contributor.author | Makarenko, V. | |
| dc.contributor.author | Mossolov, V. | |
| dc.contributor.author | Gonzalez, J. Suarez | |
| dc.contributor.author | Zykunov, V. | |
| dc.contributor.author | Shumeiko, N. | |
| dc.contributor.author | Alderweireldt, S. | |
| dc.contributor.author | De Wolf, E.A. | |
| dc.contributor.author | Janssen, X. | |
| dc.contributor.author | Lauwers, J. | |
| dc.contributor.author | Van De Klundert, M. | |
| dc.contributor.author | Van Haevermaet, H. | |
| dc.contributor.author | Van Mechelen, P. | |
| dc.contributor.author | Van Remortel, N. | |
| dc.contributor.author | Van Spilbeeck, A. | |
| dc.contributor.author | Abu Zeid, S. | |
| dc.contributor.author | Blekman, F. | |
| dc.contributor.author | D’Hondt, J. | |
| dc.contributor.author | Daci, N. | |
| dc.date.accessioned | 2026-10-18T20:29:43.981008751Z | |
| dc.date.available | 2026-10-18T20:29:43.981008751Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | The CMS tracker consists of 206 m2 of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements of tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value. © CERN 2017 for the benefit of the CMS collaboration.. | |
| dc.description.sponsorship | National Science Foundation, NSF, (1151640, 1211067, 1508869, 1606321, 1624356); National Science Foundation, NSF; Science and Technology Facilities Council, STFC, (GRIDPP, PP/E000479/1, ST/H000925/1, ST/M004775/1, ST/N001273/1); Science and Technology Facilities Council, STFC | |
| dc.identifier.doi | 10.1088/1748-0221/12/04/p04023 | |
| dc.identifier.issn | 1748-0221 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85019080779 | |
| dc.identifier.startpage | P04023 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/14939 | |
| dc.identifier.volume | 12 | |
| dc.language.iso | en | |
| dc.publisher | Institute of Physics | |
| dc.relation.ispartof | Journal of Instrumentation | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Detector alignment and calibration methods (lasers, sources, particle-beams) | |
| dc.subject | Large detector systems for particle and astroparticle physics | |
| dc.subject | Particle tracking detectors | |
| dc.subject | Particle tracking detectors (Solid-state detectors) | |
| dc.subject | Carbon fibers | |
| dc.subject | Cosmology | |
| dc.subject | Hadrons | |
| dc.subject | Mechanical stability | |
| dc.subject | Alignment methods | |
| dc.subject | Astroparticle physics | |
| dc.subject | Calibration method | |
| dc.subject | Detector alignment and calibration method (laser, source, particle-beam) | |
| dc.subject | Detector systems | |
| dc.subject | Large detector system for particle and astroparticle physic | |
| dc.subject | Large detectors | |
| dc.subject | Laser sources | |
| dc.subject | Particle tracking | |
| dc.subject | Particle tracking detector | |
| dc.subject | Particle tracking detector (solid-state detector) | |
| dc.subject | Solid state detectors | |
| dc.subject | Source particles | |
| dc.subject | Tracking detectors | |
| dc.subject | Alignment | |
| dc.title | Mechanical stability of the CMS strip tracker measured with a laser alignment system | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 2 | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS |