A Novel Flow-Injection Potentiometric Detector for Determination of Tamoxifen in Anticancer Drug Formulations

ArticleAçık Erişim

Özet

A flow-injection potentiometric detector was reported for the rapid determination of tamoxifen (TAM), by using a poly(vinyl chloride) (PVC) membrane electrode containing tamoxifen-phosphomolibdate (TAM-PM) ion-pair as electroactive component. The potentiometric quality of the electrode response was optimized. Under the optimized condition (carrier solution: 5.0×10-7 M TAM, injection volume: 20 °L, flow-rate: 2.0 mL min-1, tubing length: 10 cm), the calibration plot for TAM was linear over the concentration range of 1.0×10-4-1.0×10-2 M with a sub-Nernstian slope of 37.7 mV per decade of TAM activity and detection limit of 4.2×10-5 M. The interference effects of some common alkaline metal, alkaline earth metal, heavy metals, organic and pharmaceutical molecules on electrode response were investigated and selectivity coefficients were calculated. The relative standard deviation of the electrode response for thirteen replicate measurements of 5.0×10-4 M TAM was 1.81%. The flow-through detector system revealed sampling rates of approximately 90 injections per hour depending on the TAM concentration of the injected sample. The offered potentiometric flow-injection system was applied for the determination of TAM in pharmaceutical preparations and the obtained results were compared with High-Performance Liquid Chromatography (HPLC) results. © 2016 American Scientific Publishers.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15102Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1166/sl.2016.3568Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorColdur, Fatih
dc.contributor.authorCubuk, Osman
dc.contributor.authorTopcu, Cihan
dc.contributor.authorCaglar, Bulent
dc.date.accessioned2026-10-18T20:29:53.486490102Z
dc.date.available2026-10-18T20:29:53.486490102Z
dc.date.issued2016
dc.description.abstractA flow-injection potentiometric detector was reported for the rapid determination of tamoxifen (TAM), by using a poly(vinyl chloride) (PVC) membrane electrode containing tamoxifen-phosphomolibdate (TAM-PM) ion-pair as electroactive component. The potentiometric quality of the electrode response was optimized. Under the optimized condition (carrier solution: 5.0×10-7 M TAM, injection volume: 20 °L, flow-rate: 2.0 mL min-1, tubing length: 10 cm), the calibration plot for TAM was linear over the concentration range of 1.0×10-4-1.0×10-2 M with a sub-Nernstian slope of 37.7 mV per decade of TAM activity and detection limit of 4.2×10-5 M. The interference effects of some common alkaline metal, alkaline earth metal, heavy metals, organic and pharmaceutical molecules on electrode response were investigated and selectivity coefficients were calculated. The relative standard deviation of the electrode response for thirteen replicate measurements of 5.0×10-4 M TAM was 1.81%. The flow-through detector system revealed sampling rates of approximately 90 injections per hour depending on the TAM concentration of the injected sample. The offered potentiometric flow-injection system was applied for the determination of TAM in pharmaceutical preparations and the obtained results were compared with High-Performance Liquid Chromatography (HPLC) results. © 2016 American Scientific Publishers.
dc.identifier.doi10.1166/sl.2016.3568
dc.identifier.endpage64
dc.identifier.issn1546-198X
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84957876672
dc.identifier.startpage59
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15102
dc.identifier.volume14
dc.language.isoen
dc.publisherAmerican Scientific Publishers
dc.relation.ispartofSensor Letters
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAnti-Cancer Drug
dc.subjectFlow-Injection Analysis
dc.subjectIon-Selective Electrode
dc.subjectPharmaceutical Analysis
dc.subjectPotentiometric Detector
dc.subjectTamoxifen Determination
dc.subjectCarrier concentration
dc.subjectHeavy metals
dc.subjectHigh performance liquid chromatography
dc.subjectIon selective electrodes
dc.subjectLiquid chromatography
dc.subjectPolyvinyl chlorides
dc.subjectPotentiometers (electric measuring instruments)
dc.subjectAnticancer drug
dc.subjectFlow injection analysis
dc.subjectPotentiometric detectors
dc.subjectTamoxifen
dc.subjectElectrodes
dc.titleA Novel Flow-Injection Potentiometric Detector for Determination of Tamoxifen in Anticancer Drug Formulations
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.oa.statusgreen
rdl.source.indexSCOPUS