Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode
Özet
A new solid contact copper selective electrode with a poly (vinyl chloride) (PVC) membrane consisting of o-xylylenebis(N,N-diisobutyldithiocarbamate) as ionophore has been prepared. The main novelties of constructed ion selective electrode concept are the enhanced robustness, cheapness, and fastness due to the use of solid contacts. The electrode exhibits a rapid (< 10 seconds) and near-Nernstian response to Cu2+ activity from 10−1 to 10−6 mol/L at the pH range of 4.0–6.0. No serious interference from common ions was found. The electrode characterizes by high potential stability, reproducibility, and full repeatability. The electrode was used as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA and for the direct assay of tea infusion samples by means of the calibration graph technique. The results compared favorably with those obtained by the atomic absorption spectroscopy (AAS). © 2016
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Birinci, Aysenur | |
| dc.contributor.author | Eren, Hilal | |
| dc.contributor.author | Coldur, Fatih | |
| dc.contributor.author | Coskun, Emine | |
| dc.contributor.author | Andac, Muberra | |
| dc.date.accessioned | 2026-10-18T20:30:13.136729027Z | |
| dc.date.available | 2026-10-18T20:30:13.136729027Z | |
| dc.date.issued | 2016 | |
| dc.description.abstract | A new solid contact copper selective electrode with a poly (vinyl chloride) (PVC) membrane consisting of o-xylylenebis(N,N-diisobutyldithiocarbamate) as ionophore has been prepared. The main novelties of constructed ion selective electrode concept are the enhanced robustness, cheapness, and fastness due to the use of solid contacts. The electrode exhibits a rapid (< 10 seconds) and near-Nernstian response to Cu2+ activity from 10−1 to 10−6 mol/L at the pH range of 4.0–6.0. No serious interference from common ions was found. The electrode characterizes by high potential stability, reproducibility, and full repeatability. The electrode was used as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA and for the direct assay of tea infusion samples by means of the calibration graph technique. The results compared favorably with those obtained by the atomic absorption spectroscopy (AAS). © 2016 | |
| dc.description.sponsorship | We gratefully acknowledge the financial support of Ondokuz Mayis University Research Foundation , Samsun, Turkey (BAP; Project number PYO.Fen. 1904.10.034 ). | |
| dc.identifier.doi | 10.1016/j.jfda.2016.02.012 | |
| dc.identifier.endpage | 492 | |
| dc.identifier.issn | 1021-9498 | |
| dc.identifier.issue | 3 | |
| dc.identifier.pmcid | PMC9336652 | |
| dc.identifier.pmid | 28911553 | |
| dc.identifier.scopus | 2-s2.0-84964260527 | |
| dc.identifier.startpage | 485 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15394 | |
| dc.identifier.volume | 24 | |
| dc.identifier.wos | WOS:000387936400005 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Taiwan LLC | |
| dc.relation.ispartof | Journal of Food and Drug Analysis | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | copper | |
| dc.subject | polyvinyl chloride (PVC) membrane | |
| dc.subject | potentiometry | |
| dc.subject | solid contact | |
| dc.subject | tea infusion samples | |
| dc.subject | Hydrogen-Ion Concentration | |
| dc.subject | Ion-Selective Electrodes | |
| dc.subject | Reproducibility of Results | |
| dc.subject | Tea | |
| dc.subject | polyvinylchloride | |
| dc.subject | Article | |
| dc.subject | atomic absorption spectrometry | |
| dc.subject | controlled study | |
| dc.subject | ion selective electrode | |
| dc.subject | limit of detection | |
| dc.subject | molecular weight | |
| dc.subject | pH | |
| dc.subject | potential difference | |
| dc.subject | potentiometric titration | |
| dc.subject | reproducibility | |
| dc.subject | solid contact ion selective electrode | |
| dc.subject | stoichiometry | |
| dc.title | Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 33 | |
| rdl.citation.wos | 30 | |
| rdl.department | Department of Chemistry, Faculty of Science, Erzincan University, Erzincan, Turkey. | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |