The performance of the CMS muon detector in proton-proton collisions at √s = 7 TeV at the LHC

ArticleAçık Erişim

Özet

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at √s = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40pb-1. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 μm in the DTs, 40-150 μm in the CSCs, and 0.8-1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds. © CERN 2013 for the benefit of the CMS collaboration.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15811Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorChatrchyan, S.
dc.contributor.authorKhachatryan, V.
dc.contributor.authorSirunyan, A.M.
dc.contributor.authorTumasyan, A.
dc.contributor.authorAdam, W.
dc.contributor.authorAguilo, E.
dc.contributor.authorBergauer, T.
dc.contributor.authorDragicevic, M.
dc.contributor.authorErö, J.
dc.contributor.authorFabjan, C.
dc.contributor.authorFriedl, M.
dc.contributor.authorFrühwirth, R.
dc.contributor.authorGhete, V.M.
dc.contributor.authorHörmann, N.
dc.contributor.authorHrubec, J.
dc.contributor.authorJeitler, M.
dc.contributor.authorKiesenhofer, W.
dc.contributor.authorKnünz, V.
dc.contributor.authorKrammer, M.
dc.contributor.authorKrätschmer, I.
dc.contributor.authorLiko, D.
dc.contributor.authorMikulec, I.
dc.contributor.authorPernicka, M.
dc.contributor.authorRabady, D.
dc.contributor.authorRahbaran, B.
dc.contributor.authorRohringer, C.
dc.contributor.authorRohringer, H.
dc.contributor.authorSchöfbeck, R.
dc.contributor.authorStrauss, J.
dc.contributor.authorTaurok, A.
dc.contributor.authorWaltenberger, W.
dc.contributor.authorWulz, C.-E.
dc.contributor.authorMossolov, V.
dc.contributor.authorShumeiko, N.
dc.contributor.authorSuarez Gonzalez, J.
dc.contributor.authorBansal, M.
dc.contributor.authorBansal, S.
dc.contributor.authorCornelis, T.
dc.contributor.authorDeWolf, E.A.
dc.contributor.authorJanssen, X.
dc.contributor.authorLuyckx, S.
dc.contributor.authorMucibello, L.
dc.contributor.authorOchesanu, S.
dc.contributor.authorRoland, B.
dc.contributor.authorRougny, R.
dc.contributor.authorSelvaggi, M.
dc.contributor.authorVan Haevermaet, H.
dc.contributor.authorVan Mechelen, P.
dc.contributor.authorVan Remortel, N.
dc.contributor.authorVan Spilbeeck, A.
dc.date.accessioned2026-10-18T20:30:39.773805013Z
dc.date.available2026-10-18T20:30:39.773805013Z
dc.date.issued2013
dc.description.abstractThe performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at √s = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40pb-1. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 μm in the DTs, 40-150 μm in the CSCs, and 0.8-1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds. © CERN 2013 for the benefit of the CMS collaboration.
dc.description.sponsorship, (ST/H00081X/2); ; National Science Foundation, NSF, (0906479, 0969555, 1151640, 1205960, 1211067, 1306951, 1314131); National Science Foundation, NSF; Science and Technology Facilities Council, STFC, (GRIDPP, ST/F007094/1, ST/F007434/1, ST/I005912/1, ST/I505572/1, ST/I505580/1, ST/J004901/1, ST/J005665/1, ST/K001256/1, ST/K001604/1, ST/K001639/1, ST/K003844/1, ST/L00609X/1); Science and Technology Facilities Council, STFC; Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, SNF, (144921, 146398, 146730); Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, SNF
dc.identifier.doi10.1088/1748-0221/8/11/p11002
dc.identifier.issn1748-0221
dc.identifier.issue11
dc.identifier.scopus2-s2.0-84893097081
dc.identifier.startpageP11002
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15811
dc.identifier.volume8
dc.language.isoen
dc.publisherInstitute of Physics Publishing
dc.relation.ispartofJournal of Instrumentation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMuon spectrometers
dc.subjectParticle tracking detectors
dc.subjectParticle tracking detectors (Gaseous detectors)
dc.subjectCharged particles
dc.subjectEfficiency
dc.subjectIntelligent systems
dc.subjectMonte Carlo methods
dc.subjectNuclear instrumentation
dc.subjectTellurium compounds
dc.subjectCathode strip chambers
dc.subjectGaseous detectors
dc.subjectIntegrated luminosity
dc.subjectMuon spectrometer
dc.subjectOperational parameters
dc.subjectParticle tracking
dc.subjectProton proton collisions
dc.subjectResistive plate chambers
dc.subjectParticle spectrometers
dc.titleThe performance of the CMS muon detector in proton-proton collisions at √s = 7 TeV at the LHC
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus66
rdl.oa.statusgold
rdl.source.indexSCOPUS