ECONOMIC ANALYSIS OF EFFECT ON ENERGY SAVING OF THERMAL INSULATION AT BUILDINGS IN ERZINCAN PROVINCE

ArticleAçık Erişim

Özet

In this study, heat losses were determined in the sample heat insulated and uninsulated buildings in Erzincan Province and heat loss economic analysis was made. As a result of the study, it is identified that total heat transfer surface area in the buildings in Erzincan is 2411189,77 m(2). 31,36 per cent of this area is insulated and 68,64 per cent is uninsulted. Because, the insulted buildings' insulation thicknesses differ, 4, 5 and 8 cm insulation thickness calculations were made according to the projects that was made in Erzincan before. Assuming that the insulated buildings built with 4 cm XPS, total heating cost was determined as 194914060,8 TL/year. If the uninsulated buildings have 4 cm XPS standart total annual heating cost would decrease to 85380229,75 TL/year and there would be 43,80 per cent saving. If insulation thicknesses is 5 cm and 8 cm, total annual saving respectively would be 41,49 per cent and 38,81 per cent.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16681Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaya, Mehmet
dc.contributor.authorFirat, Ilker
dc.contributor.authorComakli, Omer
dc.date.accessioned2026-10-18T20:36:33.097019479Z
dc.date.available2026-10-18T20:36:33.097019479Z
dc.date.issued2016
dc.description.abstractIn this study, heat losses were determined in the sample heat insulated and uninsulated buildings in Erzincan Province and heat loss economic analysis was made. As a result of the study, it is identified that total heat transfer surface area in the buildings in Erzincan is 2411189,77 m(2). 31,36 per cent of this area is insulated and 68,64 per cent is uninsulted. Because, the insulted buildings' insulation thicknesses differ, 4, 5 and 8 cm insulation thickness calculations were made according to the projects that was made in Erzincan before. Assuming that the insulated buildings built with 4 cm XPS, total heating cost was determined as 194914060,8 TL/year. If the uninsulated buildings have 4 cm XPS standart total annual heating cost would decrease to 85380229,75 TL/year and there would be 43,80 per cent saving. If insulation thicknesses is 5 cm and 8 cm, total annual saving respectively would be 41,49 per cent and 38,81 per cent.
dc.identifier.endpage55
dc.identifier.issn1300-3615
dc.identifier.issue1
dc.identifier.startpage47
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16681
dc.identifier.volume36
dc.identifier.wosWOS:000377235800006
dc.language.isotr
dc.publisherTURKISH SOC THERMAL SCIENCES TECHNOLOGY
dc.relation.ispartofISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHeat losses
dc.subjectInsulation
dc.subjectEconomic analysis
dc.subjectEnergy saving
dc.subjectEXTERNAL WALLS
dc.subjectTHICKNESS
dc.subjectThermodynamics
dc.subjectEngineering, Mechanical
dc.subjectEngineering
dc.titleECONOMIC ANALYSIS OF EFFECT ON ENERGY SAVING OF THERMAL INSULATION AT BUILDINGS IN ERZINCAN PROVINCE
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos5
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)