Examination of flat plate collector solar hot water system for Ankara province in Turkiye with TRNSYS software

ArticleAçık Erişim

Özet

A domestic solar water heating system using a flat plate collector is modeled for the domestic hot water requirement of a residential unit in Ankara, Turkey. The necessary design parameters were determined and the analysis was carried out using the TRNSYS simulation program. In the modeled system, the domestic water temperature was determined as 55 degrees C and water withdrawals were carried out at different flow rates during the day according to the usage intensity. The water withdrawal rates were determined as 80 kg/h between 07.00-09.00, 100 kg/h between 12.00-13.00 and 50 kg/h between 17.00-22.00. According to the results obtained, the designed system was able to meet the hot water need in summer and winter months by using solar energy through auxiliary heaters. While the collector efficiency reached its highest value with 40% in September, it reached the lowest efficiency value with 8% in December.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16698Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSeyhan, Aslihan Kurnuc
dc.contributor.authorUzun, Sinem
dc.contributor.authorCoskun, Salih
dc.date.accessioned2026-10-18T20:36:33.876817608Z
dc.date.available2026-10-18T20:36:33.876817608Z
dc.date.issued2022
dc.description.abstractA domestic solar water heating system using a flat plate collector is modeled for the domestic hot water requirement of a residential unit in Ankara, Turkey. The necessary design parameters were determined and the analysis was carried out using the TRNSYS simulation program. In the modeled system, the domestic water temperature was determined as 55 degrees C and water withdrawals were carried out at different flow rates during the day according to the usage intensity. The water withdrawal rates were determined as 80 kg/h between 07.00-09.00, 100 kg/h between 12.00-13.00 and 50 kg/h between 17.00-22.00. According to the results obtained, the designed system was able to meet the hot water need in summer and winter months by using solar energy through auxiliary heaters. While the collector efficiency reached its highest value with 40% in September, it reached the lowest efficiency value with 8% in December.
dc.identifier.eissn2147-9429
dc.identifier.endpage1816
dc.identifier.issn1302-0900
dc.identifier.issue4
dc.identifier.startpage1809
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16698
dc.identifier.volume25
dc.identifier.wosWOS:001001850300035
dc.language.isoen
dc.publisherGAZI UNIV
dc.relation.ispartofJOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSDHW
dc.subjectsolar energy
dc.subjectTRNSYS
dc.subjectHEATING SYSTEM
dc.subjectPERFORMANCE
dc.subjectSIMULATION
dc.subjectMODEL
dc.subjectEngineering, Multidisciplinary
dc.subjectEngineering
dc.titleExamination of flat plate collector solar hot water system for Ankara province in Turkiye with TRNSYS software
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos1
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)