The plate-screw fixation is widely used in the treatment of tibia diaphysis fractures. Also the structural differences such as design variables and the connection type, locked and unlocked fixation, in plate-screw system affect biomechanical behavior of bone-implant structure. In this study, the mechanical effects of locked and unlocked plate-screw fixation systems on bone-implant structures and their effects on healing period were investigated by finite element method. For this purpose, 3D (three dimensional) fractured tibia models were constituted by considering two fracture angle (60° ve 90°) and different callus structures and then, fixations were performed. The obtained models were analyzed under axial load via ANSYS 14.0. In consequence of the performed analyses, it was obtained that locked fixation system provided more stabilization than unlocked fixation system with respect to stresses and displacements on bone-implant structures. It was observed that stresses and displacements increased in the event of fracture angle 90° instead of 60°. Also, it was concluded that the most effective parameter on the bone-implant structure was found that the mechanical properties of callus structure.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/19045Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKovacı, Halim
dc.contributor.authorKAYMAZ, İrfan
dc.contributor.authorALSARAN, Akgün
dc.contributor.authorYILDIRIM, Ömer Selim
dc.contributor.authorGHAHRAMANZADEH, Hojjat ASL
dc.contributor.authorÇELİK, Ayhan
dc.date.accessioned2026-10-18T21:03:45.147675718Z
dc.date.available2026-10-18T21:03:45.147675718Z
dc.date.issued2014
dc.description.abstractThe plate-screw fixation is widely used in the treatment of tibia diaphysis fractures. Also the structural differences such as design variables and the connection type, locked and unlocked fixation, in plate-screw system affect biomechanical behavior of bone-implant structure. In this study, the mechanical effects of locked and unlocked plate-screw fixation systems on bone-implant structures and their effects on healing period were investigated by finite element method. For this purpose, 3D (three dimensional) fractured tibia models were constituted by considering two fracture angle (60° ve 90°) and different callus structures and then, fixations were performed. The obtained models were analyzed under axial load via ANSYS 14.0. In consequence of the performed analyses, it was obtained that locked fixation system provided more stabilization than unlocked fixation system with respect to stresses and displacements on bone-implant structures. It was observed that stresses and displacements increased in the event of fracture angle 90° instead of 60°. Also, it was concluded that the most effective parameter on the bone-implant structure was found that the mechanical properties of callus structure.
dc.identifier.eissn1308-6529
dc.identifier.endpage174
dc.identifier.issn1300-7688
dc.identifier.issue3 (Biyomekanik)
dc.identifier.startpage167
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/19045
dc.identifier.volume18
dc.language.isotr
dc.relation.ispartofSüleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMühendislik
dc.subjectBiyotıp
dc.subjectAnatomi ve Morfoloji
dc.subjectMalzeme Bilimleri
dc.subjectBiyomalzemeler
dc.subjectOrtopedi
dc.titleFinite Element Analysis of Locked and Unlocked Plate Fixation Methods in Tibial Diaphyseal Fractures
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin2
rdl.departmentATATÜRK ÜNİVERSİTESİ
rdl.departmentKAFKAS ÜNİVERSİTESİ
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.source.indexTRDIZIN