  • ArticleYalnız künye2016
    ECONOMIC ANALYSIS OF EFFECT ON ENERGY SAVING OF THERMAL INSULATION AT BUILDINGS IN ERZINCAN PROVINCE

    Kaya, Mehmet; Firat, Ilker; Çomakli, Omer

    In this study, heat losses were determined in the sample heat insulated and uninsulated buildings in Erzincan Province and heat loss economic analysis was made. As a result of the study, it is identified that total heat transfer surface area in the buildings in Erzincan is 2411189,77 m(2). 31,36 per cent of this area is insulated and 68,64 per cent is uninsulted. Because, the insulted buildings' insulation thicknesses differ, 4, 5 and 8 cm insulation thickness calculations were made according to the projects that was made in Erzincan before. Assuming that the insulated buildings built with 4 cm XPS, total heating cost was determined as 194914060,8 TL/year. If the uninsulated buildings have 4 cm XPS standart total annual heating cost would decrease to 85380229,75 TL/year and there would be 43,80 per cent saving. If insulation thicknesses is 5 cm and 8 cm, total annual saving respectively would be 41,49 per cent and 38,81 per cent.

    RDL Kalıcı Kaydıİncele
  • ArticleYalnız künye2014
    ENERGY EVALUATION OF A PHASE CHANGE MATERIAL WALL COVERED WITH NOVEL TRIPLE GLASS

    Kurnuç, Aslihan; Kara, Yusuf Ali

    A research study was conducted to investigate the thermal performance of phase change material (PCM) walls. The south-facing external wall of a test room was constructed using PCM walls composed of brick walls, plasterboards containing PCMs, and novel triple glass. The thermal performance of the PCM walls was experimentally determined on a monthly basis. However, because of the unstable characteristic of the meteorological data, evaluation of any solar application is usually made using the mean values from long-term meteorological data. In addition to the experimental analysis, a theoretical performance analysis based on 10-year mean meteorological data was carried out to provide a more general conclusion about the performance of the PCM walls. The results from the theoretical analysis show that the ratio of the solar energy gain provided by the GR35 PCM wall to the heat load of the test room on a monthly basis varies from 7 to 57% during the heating period from October to May; the ratio is 16% on an annual basis.

    RDL Kalıcı Kaydıİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn1300-3615
creativeworkseries.issn2667-7725
dc.date.accessioned2026-10-20T15:48:39.324211440Z
dc.date.available2026-10-20T15:48:39.324211440Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/25851
dc.publisherTURKISH SOC THERMAL SCIENCES TECHNOLOGY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY
dspace.entity.typeJournal