Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life

ArticleAçık Erişim

Özet

Purpose Shoulder disorders may occur for procedural reasons in patients fitted with a cardiac implantable electronic device (CIED). This study aimed to examine the effects of CIED implantation on shoulder functions and scapular dyskinesis. Materials and methods Thirty patients fitted with a CIED formed the study group (SG), whilst 30 participants without a CIED formed the control group (CG). The range of motion (ROM), grip strength, lateral scapular slide test (static), scapular dyskinesis test (dynamic), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, and the Short Form-36 Health Survey (Physical and Mental Component Summary [PCS and MCS]) were applied in the study. Results The shoulder's mean flexion and abduction ROM on the implant side were found to be significantly lower in the SG than the CG (p = .016 and p = .001, respectively). Similarly, a significant grip strength loss on the implant side was detected in the SG than in the CG (p = .036). Static and dynamic scapular dyskinesis frequencies were shown to be significantly higher in the SG than in the CG (p = .002 and p< .001, respectively). The ASES Shoulder Score and PCS score were significantly lower in the SG than in the CG (p = .014 and p = .007, respectively). However, no difference was revealed between the two groups with respect to the contralateral upper limb. Conclusion The frequency of scapular dyskinesis and disability was higher, and upper limb functions, grip strength, and physical subdivision of quality of life decreased in CIED recipients. These findings suggest that such parameters should be included in physiotherapy assessment and treatment programs. Copyright: © 2023 Cosgun et al.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12194Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCosgun, Cansu
dc.contributor.authorCosgun, Muharrem Said
dc.contributor.authorBuyukturan, Oznur
dc.contributor.authorBuyukturan, Buket
dc.date.accessioned2026-10-18T20:27:07.641878702Z
dc.date.available2026-10-18T20:27:07.641878702Z
dc.date.issued2023
dc.description.abstractPurpose Shoulder disorders may occur for procedural reasons in patients fitted with a cardiac implantable electronic device (CIED). This study aimed to examine the effects of CIED implantation on shoulder functions and scapular dyskinesis. Materials and methods Thirty patients fitted with a CIED formed the study group (SG), whilst 30 participants without a CIED formed the control group (CG). The range of motion (ROM), grip strength, lateral scapular slide test (static), scapular dyskinesis test (dynamic), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, and the Short Form-36 Health Survey (Physical and Mental Component Summary [PCS and MCS]) were applied in the study. Results The shoulder's mean flexion and abduction ROM on the implant side were found to be significantly lower in the SG than the CG (p = .016 and p = .001, respectively). Similarly, a significant grip strength loss on the implant side was detected in the SG than in the CG (p = .036). Static and dynamic scapular dyskinesis frequencies were shown to be significantly higher in the SG than in the CG (p = .002 and p< .001, respectively). The ASES Shoulder Score and PCS score were significantly lower in the SG than in the CG (p = .014 and p = .007, respectively). However, no difference was revealed between the two groups with respect to the contralateral upper limb. Conclusion The frequency of scapular dyskinesis and disability was higher, and upper limb functions, grip strength, and physical subdivision of quality of life decreased in CIED recipients. These findings suggest that such parameters should be included in physiotherapy assessment and treatment programs. Copyright: © 2023 Cosgun et al.
dc.identifier.doi10.1371/journal.pone.0284178
dc.identifier.issn1932-6203
dc.identifier.issue4 April
dc.identifier.pmcidPMC10079016
dc.identifier.pmid37023118
dc.identifier.scopus2-s2.0-85151792712
dc.identifier.startpagee0284178
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12194
dc.identifier.volume18
dc.identifier.wosWOS:000969434300078
dc.language.isoen
dc.publisherPublic Library of Science
dc.relation.ispartofPLOS ONE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDyskinesias
dc.subjectHumans
dc.subjectQuality of Life
dc.subjectRange of Motion, Articular
dc.subjectScapula
dc.subjectSelf Report
dc.subjectShoulder
dc.subjectShoulder Joint
dc.subjectabduction
dc.subjectadult
dc.subjectAmerican shoulder and elbow surgeons score
dc.subjectArticle
dc.subjectassessment of humans
dc.subjectcardiac implantable electronic device implantation
dc.subjectcontralateral upper limb
dc.subjectcontrolled study
dc.subjectcross-sectional study
dc.subjectfemale
dc.subjectgrip strength
dc.subjecthuman
dc.subjectimplantation
dc.subjectipsilateral shoulder range of motion
dc.subjectlateral scapular slide test
dc.subjectLikert scale
dc.subjectmale
dc.subjectmiddle aged
dc.subjectmorbidity
dc.subjectmusculoskeletal system parameters
dc.subjectrange of motion
dc.subjectscapular dyskinesis test
dc.titleFunctional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos4
rdl.departmentDepartment of Physical Therapy and Rehabilitation, Mengucek Gazi Education and Research Hospital, Erzincan, Turkey. | Medical Faculty, Department of Cardiology, Mengucek Gazi Education and Research Hospital, Erzincan Binali Yildirim University, Erzincan, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)