Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life
Özet
Purpose Shoulder disorders may occur for procedural reasons in patients fitted with a cardiac implantable electronic device (CIED). This study aimed to examine the effects of CIED implantation on shoulder functions and scapular dyskinesis. Materials and methods Thirty patients fitted with a CIED formed the study group (SG), whilst 30 participants without a CIED formed the control group (CG). The range of motion (ROM), grip strength, lateral scapular slide test (static), scapular dyskinesis test (dynamic), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, and the Short Form-36 Health Survey (Physical and Mental Component Summary [PCS and MCS]) were applied in the study. Results The shoulder's mean flexion and abduction ROM on the implant side were found to be significantly lower in the SG than the CG (p = .016 and p = .001, respectively). Similarly, a significant grip strength loss on the implant side was detected in the SG than in the CG (p = .036). Static and dynamic scapular dyskinesis frequencies were shown to be significantly higher in the SG than in the CG (p = .002 and p< .001, respectively). The ASES Shoulder Score and PCS score were significantly lower in the SG than in the CG (p = .014 and p = .007, respectively). However, no difference was revealed between the two groups with respect to the contralateral upper limb. Conclusion The frequency of scapular dyskinesis and disability was higher, and upper limb functions, grip strength, and physical subdivision of quality of life decreased in CIED recipients. These findings suggest that such parameters should be included in physiotherapy assessment and treatment programs. Copyright: © 2023 Cosgun et al.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Cosgun, Cansu | |
| dc.contributor.author | Cosgun, Muharrem Said | |
| dc.contributor.author | Buyukturan, Oznur | |
| dc.contributor.author | Buyukturan, Buket | |
| dc.date.accessioned | 2026-10-18T20:27:07.641878702Z | |
| dc.date.available | 2026-10-18T20:27:07.641878702Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | Purpose Shoulder disorders may occur for procedural reasons in patients fitted with a cardiac implantable electronic device (CIED). This study aimed to examine the effects of CIED implantation on shoulder functions and scapular dyskinesis. Materials and methods Thirty patients fitted with a CIED formed the study group (SG), whilst 30 participants without a CIED formed the control group (CG). The range of motion (ROM), grip strength, lateral scapular slide test (static), scapular dyskinesis test (dynamic), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, and the Short Form-36 Health Survey (Physical and Mental Component Summary [PCS and MCS]) were applied in the study. Results The shoulder's mean flexion and abduction ROM on the implant side were found to be significantly lower in the SG than the CG (p = .016 and p = .001, respectively). Similarly, a significant grip strength loss on the implant side was detected in the SG than in the CG (p = .036). Static and dynamic scapular dyskinesis frequencies were shown to be significantly higher in the SG than in the CG (p = .002 and p< .001, respectively). The ASES Shoulder Score and PCS score were significantly lower in the SG than in the CG (p = .014 and p = .007, respectively). However, no difference was revealed between the two groups with respect to the contralateral upper limb. Conclusion The frequency of scapular dyskinesis and disability was higher, and upper limb functions, grip strength, and physical subdivision of quality of life decreased in CIED recipients. These findings suggest that such parameters should be included in physiotherapy assessment and treatment programs. Copyright: © 2023 Cosgun et al. | |
| dc.identifier.doi | 10.1371/journal.pone.0284178 | |
| dc.identifier.issn | 1932-6203 | |
| dc.identifier.issue | 4 April | |
| dc.identifier.pmcid | PMC10079016 | |
| dc.identifier.pmid | 37023118 | |
| dc.identifier.scopus | 2-s2.0-85151792712 | |
| dc.identifier.startpage | e0284178 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/12194 | |
| dc.identifier.volume | 18 | |
| dc.identifier.wos | WOS:000969434300078 | |
| dc.language.iso | en | |
| dc.publisher | Public Library of Science | |
| dc.relation.ispartof | PLOS ONE | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Dyskinesias | |
| dc.subject | Humans | |
| dc.subject | Quality of Life | |
| dc.subject | Range of Motion, Articular | |
| dc.subject | Scapula | |
| dc.subject | Self Report | |
| dc.subject | Shoulder | |
| dc.subject | Shoulder Joint | |
| dc.subject | abduction | |
| dc.subject | adult | |
| dc.subject | American shoulder and elbow surgeons score | |
| dc.subject | Article | |
| dc.subject | assessment of humans | |
| dc.subject | cardiac implantable electronic device implantation | |
| dc.subject | contralateral upper limb | |
| dc.subject | controlled study | |
| dc.subject | cross-sectional study | |
| dc.subject | female | |
| dc.subject | grip strength | |
| dc.subject | human | |
| dc.subject | implantation | |
| dc.subject | ipsilateral shoulder range of motion | |
| dc.subject | lateral scapular slide test | |
| dc.subject | Likert scale | |
| dc.subject | male | |
| dc.subject | middle aged | |
| dc.subject | morbidity | |
| dc.subject | musculoskeletal system parameters | |
| dc.subject | range of motion | |
| dc.subject | scapular dyskinesis test | |
| dc.title | Functional impact of cardiac implanted devices on ipsilateral shoulder range of motion, scapular mobility, and self-reported quality of life | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 5 | |
| rdl.citation.wos | 4 | |
| rdl.department | Department of Physical Therapy and Rehabilitation, Mengucek Gazi Education and Research Hospital, Erzincan, Turkey. | Medical Faculty, Department of Cardiology, Mengucek Gazi Education and Research Hospital, Erzincan Binali Yildirim University, Erzincan, Turkey. | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
