Influence of the sample thickness upon the albedo factors using 59.54 and 662 keV photon energies

ArticleAçık Erişim

Özet

The albedo factors (number, energy, and dose) of samples with different thicknesses were measured at a scattering angle of 180°. Ten samples with mass thickness between 0.081 and 0.348 g/cm2 were prepared from praseodymium powder and twelve samples with the mass thicknesses from 0.068 to 0.620 g/cm2 were prepared from hafnium powder. The samples were irritated by 59.54 and 662 keV gamma rays emitted from Am241 and Cs137 radioactive sources, respectively. The scattered photons were counted by a high purity germanium detector with active area of 200 mm2. The albedo factors decreased with the atomic number and increased with the mass thickness. © 2021 Taylor & Francis Group, LLC.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12962Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYılmaz, Demet
dc.contributor.authorAkkuş, Tuba
dc.contributor.authorKalecik, Sedanur
dc.date.accessioned2026-10-18T20:27:49.279009019Z
dc.date.available2026-10-18T20:27:49.279009019Z
dc.date.issued2022
dc.description.abstractThe albedo factors (number, energy, and dose) of samples with different thicknesses were measured at a scattering angle of 180°. Ten samples with mass thickness between 0.081 and 0.348 g/cm2 were prepared from praseodymium powder and twelve samples with the mass thicknesses from 0.068 to 0.620 g/cm2 were prepared from hafnium powder. The samples were irritated by 59.54 and 662 keV gamma rays emitted from Am241 and Cs137 radioactive sources, respectively. The scattered photons were counted by a high purity germanium detector with active area of 200 mm2. The albedo factors decreased with the atomic number and increased with the mass thickness. © 2021 Taylor & Francis Group, LLC.
dc.identifier.doi10.1080/10739149.2021.2023175
dc.identifier.eissn1525-6030
dc.identifier.endpage455
dc.identifier.issn1073-9149
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85122545125
dc.identifier.startpage447
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12962
dc.identifier.volume50
dc.identifier.wosWOS:000736819500001
dc.language.isoen
dc.publisherTaylor and Francis Ltd.
dc.relation.ispartofInstrumentation Science and Technology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAlbedo dose
dc.subjectalbedo energy
dc.subjectalbedo number
dc.subjectbackscattering technique
dc.subjecthigh purity germanium detector
dc.subjectAtoms
dc.subjectGermanium
dc.subjectPhotons
dc.subjectRadioactivity
dc.subjectSolar radiation
dc.subjectDifferent thickness
dc.subjectEnergy
dc.subjectHigh-purity germanium detector
dc.subjectMass thickness
dc.subjectPhoton energy
dc.subjectSample thickness
dc.subjectGamma rays
dc.titleInfluence of the sample thickness upon the albedo factors using 59.54 and 662 keV photon energies
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.wos2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)