Emission probabilities of K X- and γ-rays following 51Cr and 67Ga decay
ArticleAçık Erişim
Özet
Emission probabilities of K X- and γ-rays following the decay of 51Cr and 67Ga were precisely measured with a calibrated Si(Li) detector. The photopeak efficiency of the Si(Li) semiconductor detector was determined experimentally for about 4-400keV energy range by using standard sources. Results of this study have been compared with the theoretical values and other available experimental results in the literature. Good agreement was observed between our results, and other available experimental results and theoretically calculated values. © 2004 Elsevier Ltd. All rights reserved.
Anahtar Kelimeler
γ-rays emission probabilities23.20.Lv<sup>51</sup>Cr<sup>67</sup>GaElectron capture processesX-rays emission probabilitiesDetectorsSemiconducting galliumSemiconducting siliconchromium 51gallium 67lithiumsiliconarticlecalibrationelectron capture detectiongamma radiationmathematical computingpriority journalradioisotope decaysemiconductorstandardX rayEmission probabilitiesEnergy rangePhotopeak efficiencyGamma rays
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16014Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Yalçin, P. | |
| dc.contributor.author | Kurucu, Y. | |
| dc.date.accessioned | 2026-10-18T20:30:51.306703773Z | |
| dc.date.available | 2026-10-18T20:30:51.306703773Z | |
| dc.date.issued | 2005 | |
| dc.description.abstract | Emission probabilities of K X- and γ-rays following the decay of 51Cr and 67Ga were precisely measured with a calibrated Si(Li) detector. The photopeak efficiency of the Si(Li) semiconductor detector was determined experimentally for about 4-400keV energy range by using standard sources. Results of this study have been compared with the theoretical values and other available experimental results in the literature. Good agreement was observed between our results, and other available experimental results and theoretically calculated values. © 2004 Elsevier Ltd. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.apradiso.2004.05.078 | |
| dc.identifier.endpage | 67 | |
| dc.identifier.issn | 0969-8043 | |
| dc.identifier.issue | 1 | |
| dc.identifier.scopus | 2-s2.0-7444244323 | |
| dc.identifier.startpage | 63 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/16014 | |
| dc.identifier.volume | 62 | |
| dc.language.iso | en | |
| dc.relation.ispartof | Applied Radiation and Isotopes | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | γ-rays emission probabilities | |
| dc.subject | 23.20.Lv | |
| dc.subject | <sup>51</sup>Cr | |
| dc.subject | <sup>67</sup>Ga | |
| dc.subject | Electron capture processes | |
| dc.subject | X-rays emission probabilities | |
| dc.subject | Detectors | |
| dc.subject | Semiconducting gallium | |
| dc.subject | Semiconducting silicon | |
| dc.subject | chromium 51 | |
| dc.subject | gallium 67 | |
| dc.subject | lithium | |
| dc.subject | silicon | |
| dc.subject | article | |
| dc.subject | calibration | |
| dc.subject | electron capture detection | |
| dc.subject | gamma radiation | |
| dc.subject | mathematical computing | |
| dc.subject | priority journal | |
| dc.subject | radioisotope decay | |
| dc.subject | semiconductor | |
| dc.subject | standard | |
| dc.subject | X ray | |
| dc.subject | Emission probabilities | |
| dc.subject | Energy range | |
| dc.subject | Photopeak efficiency | |
| dc.subject | Gamma rays | |
| dc.title | Emission probabilities of K X- and γ-rays following 51Cr and 67Ga decay | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 14 | |
| rdl.source.index | SCOPUS |
