Proton reconstruction with the TOTEM Roman pot detectors for high-β∗ LHC data

ArticleAçık Erişim

Özet

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β∗ data-taking period at √s = 13 TeV in 2018. © 2025 CERN. Published by IOP Publishing Ltd on behalf of Sissa Medialab.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10627Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHayrapetyan, A.
dc.contributor.authorTumasyan, A.
dc.contributor.authorAdam, W.
dc.contributor.authorAndrejkovic, J.W.
dc.contributor.authorBenato, L.
dc.contributor.authorBergauer, T.
dc.contributor.authorChatterjee, S.
dc.contributor.authorDamanakis, K.
dc.contributor.authorDragicevic, M.
dc.contributor.authorHussain, P.S.
dc.contributor.authorJeitler, M.
dc.contributor.authorKrammer, N.
dc.contributor.authorLi, A.
dc.contributor.authorLiko, D.
dc.contributor.authorMikulec, I.
dc.contributor.authorSchieck, J.
dc.contributor.authorSchöfbeck, R.
dc.contributor.authorSchwarz, D.
dc.contributor.authorSonawane, M.
dc.contributor.authorWaltenberger, W.
dc.contributor.authorWulz, C.-E.
dc.contributor.authorJanssen, T.
dc.contributor.authorVan Laer, T.
dc.contributor.authorVan Mechelen, P.
dc.contributor.authorBreugelmans, N.
dc.contributor.authorD'Hondt, J.
dc.contributor.authorDansana, S.
dc.contributor.authorDe Moor, A.
dc.contributor.authorDelcourt, M.
dc.contributor.authorHeyen, F.
dc.contributor.authorLowette, S.
dc.contributor.authorMakarenko, I.
dc.contributor.authorMüller, D.
dc.contributor.authorTavernier, S.
dc.contributor.authorTytgat, M.
dc.contributor.authorVan Onsem, G.P.
dc.contributor.authorVan Putte, S.
dc.contributor.authorVannerom, D.
dc.contributor.authorBilin, B.
dc.contributor.authorClerbaux, B.
dc.contributor.authorDas, A.K.
dc.contributor.authorDe Bruyn, I.
dc.contributor.authorDe Lentdecker, G.
dc.contributor.authorEvard, H.
dc.contributor.authorFavart, L.
dc.contributor.authorGianneios, P.
dc.contributor.authorJaramillo, J.
dc.contributor.authorKhalilzadeh, A.
dc.contributor.authorKhan, F.A.
dc.contributor.authorLee, K.
dc.date.accessioned2026-10-18T20:25:48.554054228Z
dc.date.available2026-10-18T20:25:48.554054228Z
dc.date.issued2025
dc.description.abstractThe TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β∗ data-taking period at √s = 13 TeV in 2018. © 2025 CERN. Published by IOP Publishing Ltd on behalf of Sissa Medialab.
dc.identifier.doi10.1088/1748-0221/20/04/p04012
dc.identifier.issn1748-0221
dc.identifier.issue4
dc.identifier.scopus2-s2.0-105003553922
dc.identifier.startpageP04012
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10627
dc.identifier.volume20
dc.language.isoen
dc.publisherInstitute of Physics
dc.relation.ispartofJournal of Instrumentation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcalibration and fitting methods
dc.subjectcluster finding
dc.subjectPattern recognition
dc.subjectPerformance of High Energy Physics Detectors
dc.subjectHadrons
dc.subjectPhotons
dc.subjectRemote sensing
dc.subjectTellurium compounds
dc.subjectCalibration method
dc.subjectDetection efficiency
dc.subjectFitting method
dc.subjectHigh energy physics detector
dc.subjectLevel detections
dc.subjectPerformance
dc.subjectPerformance of high energy physic detector
dc.subjectRoman pots
dc.subjectTrack reconstruction
dc.titleProton reconstruction with the TOTEM Roman pot detectors for high-β∗ LHC data
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.oa.statusgold
rdl.source.indexSCOPUS