Development of Medical Device-Related Pressure Injury Risk Assessment Scale

ArticleAçık Erişim

Özet

OBJECTIVE: This study aimed to develop a valid and reliable measurement tool to assess the risk of medical device-related pressure injuries (MDRPIs) in patients. A methodological design was employed to evaluate the validity and reliability of the Medical Device-Related Pressure Injury Risk Assessment Scale (MDRPI Scale). METHODS: The study was conducted with 200 patients who were undergoing care and treatment involving the use of medical devices. Data were collected using the Patient Descriptive Characteristics Form, the MDRPI Scale, and the Braden Risk Assessment Scale. Analyses focused on evaluating the MDRPI Scale's validity and reliability. RESULTS: The content validity index of the MDRPI Scale was 0.87, and its Cronbach α coefficient was 0.73. The scale's items, which explained 47.063% of the total variance, were grouped under 2 factors: Factor 1-General Condition of the Patient, and Factor 2-Effect of the Medical Device on the Contact Area. The model fit indices obtained from the Confirmatory Factor Analysis (CFA) supported the 2-factor structure (χ2/df=2.091). No problematic items were identified within the final 8-item version of the scale. CONCLUSIONS: This study presents the first comprehensive and systematic scale specifically developed to identify MDRPI risk and to evaluate the integrity of skin and mucosa in patients exposed to medical devices. The findings demonstrate that the MDRPI Scale, consisting of 8 items and 2 factors, is a valid and reliable tool for assessing the risk of MPRPIs in clinical settings. © 2025 Wolters Kluwer Health, Inc. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10794Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAydin Kahraman, Handan
dc.contributor.authorIpek Çoban, Gulay
dc.date.accessioned2026-10-18T20:25:55.886320061Z
dc.date.available2026-10-18T20:25:55.886320061Z
dc.date.issued2025
dc.description.abstractOBJECTIVE: This study aimed to develop a valid and reliable measurement tool to assess the risk of medical device-related pressure injuries (MDRPIs) in patients. A methodological design was employed to evaluate the validity and reliability of the Medical Device-Related Pressure Injury Risk Assessment Scale (MDRPI Scale). METHODS: The study was conducted with 200 patients who were undergoing care and treatment involving the use of medical devices. Data were collected using the Patient Descriptive Characteristics Form, the MDRPI Scale, and the Braden Risk Assessment Scale. Analyses focused on evaluating the MDRPI Scale's validity and reliability. RESULTS: The content validity index of the MDRPI Scale was 0.87, and its Cronbach α coefficient was 0.73. The scale's items, which explained 47.063% of the total variance, were grouped under 2 factors: Factor 1-General Condition of the Patient, and Factor 2-Effect of the Medical Device on the Contact Area. The model fit indices obtained from the Confirmatory Factor Analysis (CFA) supported the 2-factor structure (χ2/df=2.091). No problematic items were identified within the final 8-item version of the scale. CONCLUSIONS: This study presents the first comprehensive and systematic scale specifically developed to identify MDRPI risk and to evaluate the integrity of skin and mucosa in patients exposed to medical devices. The findings demonstrate that the MDRPI Scale, consisting of 8 items and 2 factors, is a valid and reliable tool for assessing the risk of MPRPIs in clinical settings. © 2025 Wolters Kluwer Health, Inc. All rights reserved.
dc.description.sponsorshipThis study was supported by the Scientific Research Projects Atat\u00FCrk University of Turkey (BAP).
dc.identifier.doi10.1097/asw.0000000000000328
dc.identifier.eissn1538-8654
dc.identifier.endpage432
dc.identifier.issn1527-7941
dc.identifier.issue8
dc.identifier.pmid40719469
dc.identifier.scopus2-s2.0-105011977518
dc.identifier.startpage426
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10794
dc.identifier.volume38
dc.identifier.wosWOS:001555433000012
dc.language.isoen
dc.publisherLippincott Williams and Wilkins
dc.relation.ispartofAdvances in Skin and Wound Care
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectmedical device-related pressure injury
dc.subjectnursing
dc.subjectrisk assessment
dc.subjectscale
dc.subjectAdult
dc.subjectAged
dc.subjectAged, 80 and over
dc.subjectEquipment and Supplies
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectPressure Ulcer
dc.subjectReproducibility of Results
dc.subjectadverse event
dc.subjectdecubitus
dc.subjectdevices
dc.subjectdiagnosis
dc.subjectetiology
dc.subjecthuman
dc.subjectprevention and control
dc.subjectprocedures
dc.subjectreproducibility
dc.subjectvery elderly
dc.titleDevelopment of Medical Device-Related Pressure Injury Risk Assessment Scale
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.wos4
rdl.departmentHandan Aydin Kahraman, PhD, is Assistant Professor, Erzincan Binali Yildirim University Faculty of Health Sciences, Erzincan, Turkey. Gulay Ipek Çoban, PhD, is Professor, Department of Nursing Fundamentals, Atatürk University Faculty of Nursing, Erzurum, Turkey.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)
rdl.wos.indexSocial Science Citation Index (SSCI)