An experimental evaluation on structural performance level of corroded reinforced concrete frames

ArticleAçık Erişim

Özet

A total of 5 full-scale Reinforced Concrete (RC) frames were tested to develop new models for predicting the structural behavior of corroded RC frames and to verify the accuracy of the models mostly developed for RC columns. Four corroded and one non-corroded RC frame were tested under cyclic loading. Corroded RC frames were tested under displacement-controlled cyclic loading at four corrosion levels and for a constant applied axial load ratio of 0.20, with the same concrete compression strength level and reinforcement bar layout. Actual corrosion ratios were obtained following the loading tests, breaking all RC columns and beams and extracting all reinforcement bars from concrete. The test results demonstrated that the corrosion level played an active role in the structural capacity of the RC frames. Initial corrosion crack widths had more significant effects on structural performance. Some models proposed for corroded RC columns can also be used for corroded RC frames in terms of yield and ultimate load capacities according to the corrosion levels of the columns and beam composing the RC frame. It was also concluded from the test results that the displacement-based ductility ratio for corroded RC frames could still be misleading if they were not computed according to energy-based or bilateral failure criteria. Structural properties such as initial/secant stiffness and energy absorption capacity calculated based on experimental measurements for RC frames had further disclosed corrosion effects. © 2024 Elsevier Ltd

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11017Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTuran, Ahmet İhsan
dc.contributor.authorAyaz, Yaşar
dc.contributor.authorYalciner, Hakan
dc.contributor.authorKumbasaroglu, Atila
dc.date.accessioned2026-10-18T20:26:07.427866592Z
dc.date.available2026-10-18T20:26:07.427866592Z
dc.date.issued2025
dc.description.abstractA total of 5 full-scale Reinforced Concrete (RC) frames were tested to develop new models for predicting the structural behavior of corroded RC frames and to verify the accuracy of the models mostly developed for RC columns. Four corroded and one non-corroded RC frame were tested under cyclic loading. Corroded RC frames were tested under displacement-controlled cyclic loading at four corrosion levels and for a constant applied axial load ratio of 0.20, with the same concrete compression strength level and reinforcement bar layout. Actual corrosion ratios were obtained following the loading tests, breaking all RC columns and beams and extracting all reinforcement bars from concrete. The test results demonstrated that the corrosion level played an active role in the structural capacity of the RC frames. Initial corrosion crack widths had more significant effects on structural performance. Some models proposed for corroded RC columns can also be used for corroded RC frames in terms of yield and ultimate load capacities according to the corrosion levels of the columns and beam composing the RC frame. It was also concluded from the test results that the displacement-based ductility ratio for corroded RC frames could still be misleading if they were not computed according to energy-based or bilateral failure criteria. Structural properties such as initial/secant stiffness and energy absorption capacity calculated based on experimental measurements for RC frames had further disclosed corrosion effects. © 2024 Elsevier Ltd
dc.description.sponsorshipThis study was financed by the Scientific Research Projects Commissions of Inonu University under grant number FBA-2021-2483. The authors wish to express their gratitude and greatly appreciate the financial support provided by the Scientific Research Projects Commissions. Within the scope of the study, we would like to thank Res. Assist. Alper Celik for his support during the tests.
dc.identifier.doi10.1016/j.engstruct.2024.119479
dc.identifier.eissn1873-7323
dc.identifier.issn0141-0296
dc.identifier.scopus2-s2.0-85212190081
dc.identifier.startpage119479
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11017
dc.identifier.volume325
dc.identifier.wosWOS:001390984000001
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEngineering Structures
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAccelerated corrosion
dc.subjectCorrosion
dc.subjectRC frame
dc.subjectReinforcement bar
dc.subjectStructural behavior
dc.subjectCompressive strength
dc.subjectCyclic loads
dc.subjectStructural frames
dc.subjectAxial load ratio
dc.subjectCorrosion levels
dc.subjectExperimental evaluation
dc.subjectPerformance:level
dc.subjectReinforced concrete column
dc.subjectReinforced concrete frames
dc.subjectStructural behaviors
dc.subjectStructural performance
dc.subjectconcrete structure
dc.subjectexperimental study
dc.subjectperformance assessment
dc.subjectreinforced concrete
dc.subjectreinforcement
dc.subjectstructural analysis
dc.subjectCorrosive effects
dc.titleAn experimental evaluation on structural performance level of corroded reinforced concrete frames
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus25
rdl.citation.wos19
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)