Fabrication of a novel potentiometric sensor based on graphite/carbon nanotube composite paste modified by lead(II)sulfide for efficient determination of copper(II) ions

ArticleAçık Erişim

Özet

A simple fabrication route for an all-solid-state carbon paste Cu(II)-selective potentiometric sensor on the basis of composite sensing layer consisting of PbS microparticles, graphite (G), multi-walled carbon nanotube, and paraffin oil has been propounded. Optimization studies for sensing composite layer signified that the composite contained 10 mg PbS, 10 mg MWCNT, 60 mg G, and 20 mg PO exposed the most promising potentiometric performance properties. The sensor displayed a stable and selective linear response to Cu(II) ions in the concentration range of 1.0 × 10−6–1.0 × 10−2 M (R2 = 0.9992) with an average potential change of 30.2 mV/decade. Detection limit, response time, and life-span of the sensor were determined as 5.0 × 10−7 M, 15 s, and 3 weeks, respectively. The fabricated sensor was successfully used in practical applications, serving as an indicator electrode to determine the end-point of Cu(II) titrations and to measure Cu(II) content in Cu(II)-spiked tap water samples. Graphical abstract: (Figure presented.) © The Author(s), under exclusive licence to the Institute of Chemistry, Slovak Academy of Sciences 2024.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11132Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11696-024-03703-zYayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOgul, Gulhan
dc.contributor.authorColdur, Fatih
dc.contributor.authorCubuk, Osman
dc.date.accessioned2026-10-18T20:26:13.788565690Z
dc.date.available2026-10-18T20:26:13.788565690Z
dc.date.issued2024
dc.description.abstractA simple fabrication route for an all-solid-state carbon paste Cu(II)-selective potentiometric sensor on the basis of composite sensing layer consisting of PbS microparticles, graphite (G), multi-walled carbon nanotube, and paraffin oil has been propounded. Optimization studies for sensing composite layer signified that the composite contained 10 mg PbS, 10 mg MWCNT, 60 mg G, and 20 mg PO exposed the most promising potentiometric performance properties. The sensor displayed a stable and selective linear response to Cu(II) ions in the concentration range of 1.0 × 10−6–1.0 × 10−2 M (R2 = 0.9992) with an average potential change of 30.2 mV/decade. Detection limit, response time, and life-span of the sensor were determined as 5.0 × 10−7 M, 15 s, and 3 weeks, respectively. The fabricated sensor was successfully used in practical applications, serving as an indicator electrode to determine the end-point of Cu(II) titrations and to measure Cu(II) content in Cu(II)-spiked tap water samples. Graphical abstract: (Figure presented.) © The Author(s), under exclusive licence to the Institute of Chemistry, Slovak Academy of Sciences 2024.
dc.identifier.doi10.1007/s11696-024-03703-z
dc.identifier.eissn2585-7290
dc.identifier.endpage8729
dc.identifier.issn0366-6352
dc.identifier.issue16
dc.identifier.scopus2-s2.0-85205081248
dc.identifier.startpage8719
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11132
dc.identifier.volume78
dc.identifier.wosWOS:001324617500002
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofChemical Papers
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAll-solid-state electrode
dc.subjectCarbon paste electrode
dc.subjectCopper(II) determination
dc.subjectLead(II) sulfide
dc.subjectPotentiometric determination
dc.subjectPotentiometric titration
dc.titleFabrication of a novel potentiometric sensor based on graphite/carbon nanotube composite paste modified by lead(II)sulfide for efficient determination of copper(II) ions
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus1
rdl.citation.wos1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)