Experimental and numerical investigation of the stenosed coronary artery taken from the clinical setting and modeled in terms of hemodynamics

ArticleAçık Erişim

Özet

The study was carried out to investigate the effect of the artery with different pulse values and stenosis rates on the pressure drop, the peristaltic pump outlet pressure, fractional flow reserve (FFR) and most importantly the amount of power consumed by the peristaltic pump. For this purpose, images taken from the clinical environment were produced as models (10 mm inlet diameter) with 0% and 70% percent areal stenosis rates (PSR) on a three-dimensional (3D) printer. In the experimental system, pure water was used as the fluid at 54, 84, 114, 132, and 168 bpm pulse values. In addition, computational fluid dynamics (CFD) analyzes of the test region were performed using experimental boundary conditions with the help of ANSYS-Fluent software. The findings showed that as PSR increases in the arteries, the pressure drop in the stenosis region increases and this amount increases dramatically with increasing effort. An increase of approximately 40% was observed in the pump outlet pressure value from 54 bpm to 168 bpm in the PSR 0% model and 51% increase in the PSR 70% model. It has been observed that the pump does more work to overcome the increased pressure difference due to increased pulse rate and PSR. With the effect of contraction, the power consumption of the pump increased from 9.2% for 54 bpm to 13.8% for 168 bpm. In both models, the Wall Shear Stress (WSS) increased significantly. WSS increased abruptly in the stenosis and arcuate regions, while sudden decreases were observed in the flow separation region. © 2023 John Wiley & Sons Ltd.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11543Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/cnm.3793Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSonmez, Fatin
dc.contributor.authorKaragoz, Sendogan
dc.contributor.authorYildirim, Orhan
dc.contributor.authorFirat, Ilker
dc.date.accessioned2026-10-18T20:26:34.691196048Z
dc.date.available2026-10-18T20:26:34.691196048Z
dc.date.issued2024
dc.description.abstractThe study was carried out to investigate the effect of the artery with different pulse values and stenosis rates on the pressure drop, the peristaltic pump outlet pressure, fractional flow reserve (FFR) and most importantly the amount of power consumed by the peristaltic pump. For this purpose, images taken from the clinical environment were produced as models (10 mm inlet diameter) with 0% and 70% percent areal stenosis rates (PSR) on a three-dimensional (3D) printer. In the experimental system, pure water was used as the fluid at 54, 84, 114, 132, and 168 bpm pulse values. In addition, computational fluid dynamics (CFD) analyzes of the test region were performed using experimental boundary conditions with the help of ANSYS-Fluent software. The findings showed that as PSR increases in the arteries, the pressure drop in the stenosis region increases and this amount increases dramatically with increasing effort. An increase of approximately 40% was observed in the pump outlet pressure value from 54 bpm to 168 bpm in the PSR 0% model and 51% increase in the PSR 70% model. It has been observed that the pump does more work to overcome the increased pressure difference due to increased pulse rate and PSR. With the effect of contraction, the power consumption of the pump increased from 9.2% for 54 bpm to 13.8% for 168 bpm. In both models, the Wall Shear Stress (WSS) increased significantly. WSS increased abruptly in the stenosis and arcuate regions, while sudden decreases were observed in the flow separation region. © 2023 John Wiley & Sons Ltd.
dc.description.sponsorshipThe authors would like to thank Atatürk University for providing both the laboratory where the experiments were performed and the Computational Fluid Dynamics (CFD) simulation software ANSYS-Fluent.
dc.identifier.doi10.1002/cnm.3793
dc.identifier.eissn2040-7947
dc.identifier.issn2040-7939
dc.identifier.issue1
dc.identifier.pmid37975163
dc.identifier.scopus2-s2.0-85177060675
dc.identifier.startpagee3793
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11543
dc.identifier.volume40
dc.identifier.wosWOS:001106157800001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofInternational Journal for Numerical Methods in Biomedical Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCFD
dc.subjectheart
dc.subjectpressure drop
dc.subjectpulse
dc.subjectstenosis
dc.subjectComputer Simulation
dc.subjectConstriction, Pathologic
dc.subjectCoronary Stenosis
dc.subjectCoronary Vessels
dc.subjectFractional Flow Reserve, Myocardial
dc.subjectHemodynamics
dc.subjectHumans
dc.subjectModels, Cardiovascular
dc.subject3D printing
dc.subjectComputational fluid dynamics
dc.subjectDrops
dc.subjectFlow separation
dc.subjectOptical pumping
dc.subjectPumps
dc.subjectShear stress
dc.subjectSoftware testing
dc.subjectClinical settings
dc.subjectExperimental investigations
dc.subjectNumerical investigations
dc.subjectOutlet pressures
dc.subjectPeristaltic pump
dc.subjectStenosed coronary arteries
dc.subjectStenoses
dc.subjectWall shear stress
dc.subjectWall-shear stress
dc.titleExperimental and numerical investigation of the stenosed coronary artery taken from the clinical setting and modeled in terms of hemodynamics
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus6
rdl.citation.wos6
rdl.departmentIlic Dursun Yildirim Vocational School, Erzincan Binali Yildirim University, Erzincan, Turkey.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)