Virtual non-enhanced dual-energy computed tomography reconstruction: a candidate to replace true non-enhanced computed tomography scans in the setting of suspected liver alveolar echinococcosis
Özet
PURPOSE When a suspected hepatic alveolar echinococcosis (AE) lesion is detected on a contrast enhanced computed tomography (CT) scan, an additional triphasic or non-enhanced CT scan is required to determine the presence of calcification and enhancement. As a result, imaging costs and exposure to ionizing radiation will increase. We can create a non-enhanced series from routine contrast-en-hanced images using dual-energy CT (DECT) and virtual non-enhanced (VNE) images. This study’s objective is to assess virtual non-enhanced DECT reconstruction as a potential diagnostic tool for hepatic AE. METHODS Triphasic CT scans and a routine dual energy venous phase were acquired using a third-generation DECT system. A commercially available software package was used to generate VNE images. Indi-vidual evaluations were conducted by two radiologists. RESULTS The study population consisted of 100 patients (30 AE, 70 other solid liver masses). All AE cases were diagnosed [no false positives/negatives, 95% confidence interval (CI) sensitivity: 91.3%–100%; 95% CI specificity: 95.3%–100%]. Interrater agreement was k: 0.79. In total, 33 (33.00%) of the patients had AE, which was detected using both true non-enhanced (TNE) and VNE images. The mean dose-length product of a standard triphasic CT was significantly higher than biphasic dual-energy VNE images. CONCLUSION In terms of diagnostic confidence, VNE images are comparable with actual non-enhanced imaging when evaluating hepatic AE. Further, VNE images could replace TNE images with a substantial radiation dose reduction. Advances in knowledge: hepatic cystic echinococcosis and AE are serious and severe diseases with high fatality rates and a poor prognosis if managed incorrectly, especially AE. Moreover, VNE images produce equal diagnostic confidence to TNE images for assessing liver AE, with a significant reduction in radiation dose. © 2023, Galenos Publishing House. All rights reserved.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kantarcı, Mecit | |
| dc.contributor.author | Aydın, Sonay | |
| dc.contributor.author | Kahraman, Ayşegül | |
| dc.contributor.author | Oğul, Hayri | |
| dc.contributor.author | İrgül, Barış | |
| dc.contributor.author | Levent, Akın | |
| dc.date.accessioned | 2026-10-18T20:26:41.263546043Z | |
| dc.date.available | 2026-10-18T20:26:41.263546043Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | PURPOSE When a suspected hepatic alveolar echinococcosis (AE) lesion is detected on a contrast enhanced computed tomography (CT) scan, an additional triphasic or non-enhanced CT scan is required to determine the presence of calcification and enhancement. As a result, imaging costs and exposure to ionizing radiation will increase. We can create a non-enhanced series from routine contrast-en-hanced images using dual-energy CT (DECT) and virtual non-enhanced (VNE) images. This study’s objective is to assess virtual non-enhanced DECT reconstruction as a potential diagnostic tool for hepatic AE. METHODS Triphasic CT scans and a routine dual energy venous phase were acquired using a third-generation DECT system. A commercially available software package was used to generate VNE images. Indi-vidual evaluations were conducted by two radiologists. RESULTS The study population consisted of 100 patients (30 AE, 70 other solid liver masses). All AE cases were diagnosed [no false positives/negatives, 95% confidence interval (CI) sensitivity: 91.3%–100%; 95% CI specificity: 95.3%–100%]. Interrater agreement was k: 0.79. In total, 33 (33.00%) of the patients had AE, which was detected using both true non-enhanced (TNE) and VNE images. The mean dose-length product of a standard triphasic CT was significantly higher than biphasic dual-energy VNE images. CONCLUSION In terms of diagnostic confidence, VNE images are comparable with actual non-enhanced imaging when evaluating hepatic AE. Further, VNE images could replace TNE images with a substantial radiation dose reduction. Advances in knowledge: hepatic cystic echinococcosis and AE are serious and severe diseases with high fatality rates and a poor prognosis if managed incorrectly, especially AE. Moreover, VNE images produce equal diagnostic confidence to TNE images for assessing liver AE, with a significant reduction in radiation dose. © 2023, Galenos Publishing House. All rights reserved. | |
| dc.identifier.doi | 10.4274/dir.2023.221806 | |
| dc.identifier.eissn | 1305-3612 | |
| dc.identifier.endpage | 740 | |
| dc.identifier.issn | 1305-3825 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pmcid | PMC10679563 | |
| dc.identifier.pmid | 37042415 | |
| dc.identifier.scopus | 2-s2.0-85176413406 | |
| dc.identifier.startpage | 736 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/11671 | |
| dc.identifier.volume | 29 | |
| dc.identifier.wos | WOS:001132417500001 | |
| dc.language.iso | en | |
| dc.publisher | Galenos Publishing House | |
| dc.relation.ispartof | Diagnostic and Interventional Radiology | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | alveolar echinococcosis | |
| dc.subject | DECT | |
| dc.subject | DLP | |
| dc.subject | radiation | |
| dc.subject | virtual non-enhanced | |
| dc.subject | Contrast Media | |
| dc.subject | Echinococcosis, Hepatic | |
| dc.subject | Humans | |
| dc.subject | Radiography, Dual-Energy Scanned Projection | |
| dc.subject | Retrospective Studies | |
| dc.subject | Tomography, X-Ray Computed | |
| dc.subject | iohexol | |
| dc.subject | contrast medium | |
| dc.subject | adult | |
| dc.subject | aged | |
| dc.subject | Article | |
| dc.subject | calcification | |
| dc.subject | cohort analysis | |
| dc.subject | diagnostic value | |
| dc.subject | dual energy computed tomography | |
| dc.subject | false positive result | |
| dc.subject | female | |
| dc.subject | human | |
| dc.subject | image artifact | |
| dc.subject | image quality | |
| dc.subject | image reconstruction | |
| dc.subject | male | |
| dc.subject | radiation dose | |
| dc.subject | radiation dose reduction | |
| dc.subject | radiation exposure | |
| dc.title | Virtual non-enhanced dual-energy computed tomography reconstruction: a candidate to replace true non-enhanced computed tomography scans in the setting of suspected liver alveolar echinococcosis | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 2 | |
| rdl.citation.trdizin | 0 | |
| rdl.citation.wos | 3 | |
| rdl.department | ERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ | |
| rdl.department | ATATÜRK ÜNİVERSİTESİ | |
| rdl.department | İNÖNÜ ÜNİVERSİTESİ | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | TRDIZIN | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |