Virtual non-enhanced dual-energy computed tomography reconstruction: a candidate to replace true non-enhanced computed tomography scans in the setting of suspected liver alveolar echinococcosis

ArticleAçık Erişim

Özet

PURPOSE When a suspected hepatic alveolar echinococcosis (AE) lesion is detected on a contrast enhanced computed tomography (CT) scan, an additional triphasic or non-enhanced CT scan is required to determine the presence of calcification and enhancement. As a result, imaging costs and exposure to ionizing radiation will increase. We can create a non-enhanced series from routine contrast-en-hanced images using dual-energy CT (DECT) and virtual non-enhanced (VNE) images. This study’s objective is to assess virtual non-enhanced DECT reconstruction as a potential diagnostic tool for hepatic AE. METHODS Triphasic CT scans and a routine dual energy venous phase were acquired using a third-generation DECT system. A commercially available software package was used to generate VNE images. Indi-vidual evaluations were conducted by two radiologists. RESULTS The study population consisted of 100 patients (30 AE, 70 other solid liver masses). All AE cases were diagnosed [no false positives/negatives, 95% confidence interval (CI) sensitivity: 91.3%–100%; 95% CI specificity: 95.3%–100%]. Interrater agreement was k: 0.79. In total, 33 (33.00%) of the patients had AE, which was detected using both true non-enhanced (TNE) and VNE images. The mean dose-length product of a standard triphasic CT was significantly higher than biphasic dual-energy VNE images. CONCLUSION In terms of diagnostic confidence, VNE images are comparable with actual non-enhanced imaging when evaluating hepatic AE. Further, VNE images could replace TNE images with a substantial radiation dose reduction. Advances in knowledge: hepatic cystic echinococcosis and AE are serious and severe diseases with high fatality rates and a poor prognosis if managed incorrectly, especially AE. Moreover, VNE images produce equal diagnostic confidence to TNE images for assessing liver AE, with a significant reduction in radiation dose. © 2023, Galenos Publishing House. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11671Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.4274/dir.2023.221806Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKantarcı, Mecit
dc.contributor.authorAydın, Sonay
dc.contributor.authorKahraman, Ayşegül
dc.contributor.authorOğul, Hayri
dc.contributor.authorİrgül, Barış
dc.contributor.authorLevent, Akın
dc.date.accessioned2026-10-18T20:26:41.263546043Z
dc.date.available2026-10-18T20:26:41.263546043Z
dc.date.issued2023
dc.description.abstractPURPOSE When a suspected hepatic alveolar echinococcosis (AE) lesion is detected on a contrast enhanced computed tomography (CT) scan, an additional triphasic or non-enhanced CT scan is required to determine the presence of calcification and enhancement. As a result, imaging costs and exposure to ionizing radiation will increase. We can create a non-enhanced series from routine contrast-en-hanced images using dual-energy CT (DECT) and virtual non-enhanced (VNE) images. This study’s objective is to assess virtual non-enhanced DECT reconstruction as a potential diagnostic tool for hepatic AE. METHODS Triphasic CT scans and a routine dual energy venous phase were acquired using a third-generation DECT system. A commercially available software package was used to generate VNE images. Indi-vidual evaluations were conducted by two radiologists. RESULTS The study population consisted of 100 patients (30 AE, 70 other solid liver masses). All AE cases were diagnosed [no false positives/negatives, 95% confidence interval (CI) sensitivity: 91.3%–100%; 95% CI specificity: 95.3%–100%]. Interrater agreement was k: 0.79. In total, 33 (33.00%) of the patients had AE, which was detected using both true non-enhanced (TNE) and VNE images. The mean dose-length product of a standard triphasic CT was significantly higher than biphasic dual-energy VNE images. CONCLUSION In terms of diagnostic confidence, VNE images are comparable with actual non-enhanced imaging when evaluating hepatic AE. Further, VNE images could replace TNE images with a substantial radiation dose reduction. Advances in knowledge: hepatic cystic echinococcosis and AE are serious and severe diseases with high fatality rates and a poor prognosis if managed incorrectly, especially AE. Moreover, VNE images produce equal diagnostic confidence to TNE images for assessing liver AE, with a significant reduction in radiation dose. © 2023, Galenos Publishing House. All rights reserved.
dc.identifier.doi10.4274/dir.2023.221806
dc.identifier.eissn1305-3612
dc.identifier.endpage740
dc.identifier.issn1305-3825
dc.identifier.issue6
dc.identifier.pmcidPMC10679563
dc.identifier.pmid37042415
dc.identifier.scopus2-s2.0-85176413406
dc.identifier.startpage736
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11671
dc.identifier.volume29
dc.identifier.wosWOS:001132417500001
dc.language.isoen
dc.publisherGalenos Publishing House
dc.relation.ispartofDiagnostic and Interventional Radiology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectalveolar echinococcosis
dc.subjectDECT
dc.subjectDLP
dc.subjectradiation
dc.subjectvirtual non-enhanced
dc.subjectContrast Media
dc.subjectEchinococcosis, Hepatic
dc.subjectHumans
dc.subjectRadiography, Dual-Energy Scanned Projection
dc.subjectRetrospective Studies
dc.subjectTomography, X-Ray Computed
dc.subjectiohexol
dc.subjectcontrast medium
dc.subjectadult
dc.subjectaged
dc.subjectArticle
dc.subjectcalcification
dc.subjectcohort analysis
dc.subjectdiagnostic value
dc.subjectdual energy computed tomography
dc.subjectfalse positive result
dc.subjectfemale
dc.subjecthuman
dc.subjectimage artifact
dc.subjectimage quality
dc.subjectimage reconstruction
dc.subjectmale
dc.subjectradiation dose
dc.subjectradiation dose reduction
dc.subjectradiation exposure
dc.titleVirtual non-enhanced dual-energy computed tomography reconstruction: a candidate to replace true non-enhanced computed tomography scans in the setting of suspected liver alveolar echinococcosis
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.trdizin0
rdl.citation.wos3
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentATATÜRK ÜNİVERSİTESİ
rdl.departmentİNÖNÜ ÜNİVERSİTESİ
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)