Distinguishing Parkinson’s Disease with GLCM Features from the Hankelization of EEG Signals

ArticleAçık Erişim

Özet

This study proposes a novel method that uses electroencephalography (EEG) signals to classify Parkinson’s Disease (PD) and demographically matched healthy control groups. The method utilizes the reduced beta activity and amplitude decrease in EEG signals that are associated with PD. The study involved 61 PD patients and 61 demographically matched controls groups, and EEG signals were recorded in various conditions (eyes closed, eyes open, eyes both open and closed, on-drug, off-drug) from three publicly available EEG data sources (New Mexico, Iowa, and Turku). The preprocessed EEG signals were classified using features obtained from gray-level co-occurrence matrix (GLCM) features through the Hankelization of EEG signals. The performance of classifiers with these novel features was evaluated using extensive cross-validations (CV) and leave-one-out cross-validation (LOOCV) schemes. This method under 10 × 10 fold CV, the method was able to differentiate PD groups from healthy control groups using a support vector machine (SVM) with an accuracy of 92.4 ± 0.01, 85.7 ± 0.02, and 77.1 ± 0.06 for New Mexico, Iowa, and Turku datasets, respectively. After a head-to-head comparison with state-of-the-art methods, this study showed an increase in the classification of PD and controls. © 2023 by the authors.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12032Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/diagnostics13101769Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKarakaş, Mehmet Fatih
dc.contributor.authorLatifoğlu, Fatma
dc.date.accessioned2026-10-18T20:26:59.555289006Z
dc.date.available2026-10-18T20:26:59.555289006Z
dc.date.issued2023
dc.description.abstractThis study proposes a novel method that uses electroencephalography (EEG) signals to classify Parkinson’s Disease (PD) and demographically matched healthy control groups. The method utilizes the reduced beta activity and amplitude decrease in EEG signals that are associated with PD. The study involved 61 PD patients and 61 demographically matched controls groups, and EEG signals were recorded in various conditions (eyes closed, eyes open, eyes both open and closed, on-drug, off-drug) from three publicly available EEG data sources (New Mexico, Iowa, and Turku). The preprocessed EEG signals were classified using features obtained from gray-level co-occurrence matrix (GLCM) features through the Hankelization of EEG signals. The performance of classifiers with these novel features was evaluated using extensive cross-validations (CV) and leave-one-out cross-validation (LOOCV) schemes. This method under 10 × 10 fold CV, the method was able to differentiate PD groups from healthy control groups using a support vector machine (SVM) with an accuracy of 92.4 ± 0.01, 85.7 ± 0.02, and 77.1 ± 0.06 for New Mexico, Iowa, and Turku datasets, respectively. After a head-to-head comparison with state-of-the-art methods, this study showed an increase in the classification of PD and controls. © 2023 by the authors.
dc.identifier.doi10.3390/diagnostics13101769
dc.identifier.eissn2075-4418
dc.identifier.issn2075-4418
dc.identifier.issue10
dc.identifier.pmcidPMC10216898
dc.identifier.pmid37238253
dc.identifier.scopus2-s2.0-85160534723
dc.identifier.startpage1769
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12032
dc.identifier.volume13
dc.identifier.wosWOS:000996735700001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofDiagnostics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectclassifier
dc.subjectdiagnosis
dc.subjectEEG
dc.subjectGLCM features
dc.subjectHankel matrix
dc.subjectParkinson’s disease
dc.subjectadult
dc.subjectaged
dc.subjectArticle
dc.subjectBeck Depression Inventory
dc.subjectbeta rhythm
dc.subjectcomparative study
dc.subjectcomputer graphics
dc.subjectcontrolled study
dc.subjectcross validation
dc.subjectdiagnostic accuracy
dc.subjectdiagnostic test accuracy study
dc.subjectelectroencephalogram
dc.subjectelectroencephalography
dc.subjectfeature extraction
dc.subjectfeature selection
dc.subjectfeedforward network
dc.subjectfemale
dc.subjecthankelization gray level co occurrence matrix feature
dc.subjecthuman
dc.subjectimage processing
dc.subjectk nearest neighbor
dc.subjectleave one out cross validation
dc.subjectmajor clinical study
dc.subjectmale
dc.titleDistinguishing Parkinson’s Disease with GLCM Features from the Hankelization of EEG Signals
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus22
rdl.citation.wos11
rdl.departmentFaculty of Engineering and Architecture, Department of Biomedical Engineering, Erzincan Binali Yildirim University, Erzincan 24002, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)